Gebruiksaanwijzing /service van het product TRS 3064 van de fabrikant Eaton
Ga naar pagina of 13
TRS 3064 Installation, Operation and Maintenance of the Airflex@ Timing Rotorseal and Cam Limit Switch Revised: Feb. 1, 1982.
1.0 Operation Throughout this manual, there are a number of Hazard Warnings that must be read and understood in order to prevent possible personal injury and/or damage to the equipment. Carefully read these warn- ings. They are included to protect you! 1.
Figure 1 illustrates the cams assembled in the timing section of both devices and their relationships. 1 Cam No. 2 Cam Insert No. 3 Cam No. 4 Cam insert No.
Cam No. 3 (28 and 28A) monitors the effective- ness of the press braking system at the top of the stroke. When cam No. 3 is positioned according to Paragraph 2.3, deviations in stopping position greater than + 15” from top dead center will be detected.
2.1.2. To a) b) c) d) e) f) g) h) i) j) mount the timing rotorseal: Make sure that the air tube “O” rings (2) are in place. Install the plastic insert (37A) in the head of the drive screw (37). Install drive screw. Tighten the screw, being careful not to distort the end plate (36).
Before mounting the timer, check to be sure its direction of rotation corresponds to that of the shaft. Fasten the flange to the shaft with lockwashers and cap screws. Refer to appropriate paragraph and mount second timer. W iring instructions are given in Paragraph 2.
m) Retighten the jam nuts (30) and repeat Steps “f”, “g” and “h”. n) Repeat this procedure as necessary to ob- tain the desired stopping position. 2.3.2 Long Operation: This feature is provided so an adjustment can be made to extend the LS4 open time and accommodate presses with long strokes and/or slow crankshaft speeds.
Breaker Point Opening Gap: This gap is preset at the factory on new units at time of assembly. A gap setting of .040” to .050” must be maintained at all times. The opening gap must be checked regularly and reset when required. To inspect for proper opening gap: a) b) c) d) e) h) i) j) k) Position the crankshaft at top dead center.
o) P) q) r) s) t) u) v) w) Align No. 5 cam with previously establish- ed top stop mark by rotating cam adjusting knob. Maintain No. 5 cam alignment by holding adjusting knob. Rotate No. 3 cam so that indicator groove lines up with the fiber cam follower on LS3 breaker point.
.
Item No. - 6. 20. 22. 23. 24. 25. 26. 27. 28. 28A 29. 30. 31. 32. 33. 33A 34 38. 40. 41. 42. 45. 46. 47. Part No. Description 302276 159 x 41 139 x 12 See table C See table C 201854 See table C 201869.
FOOT MOUNTED CAM LIMIT SWITCH Part No. for Optional Cam No. 3 (Item No. 28A), is as follows: 203002 (For clockwise and clockwise 30” dwell) 203087 (for c’clockwise and c’clockwise 30” dwell) Eaton Corporation Airflex Division Cleveland, Ohio 44144 PWNTED IN u.
PDF form at Form ML-31 8 Revised September 3, 1997 Eaton Cor poration Airflex Division 9919 Clinton Road Cleveland, Ohio 44144 Printed in U.S.A. EAT ON PROD UCT WARR ANTY Subject to t he c ondit io ns.
Een belangrijk punt na aankoop van elk apparaat Eaton TRS 3064 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Eaton TRS 3064 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Eaton TRS 3064 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Eaton TRS 3064 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Eaton TRS 3064 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Eaton TRS 3064 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Eaton TRS 3064 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Eaton TRS 3064 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.