Gebruiksaanwijzing /service van het product 70403 van de fabrikant Edelbrock
Ga naar pagina of 22
Page 1 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 1999-2003 FORD F-150 LIGHTNING PERFORMER EFI SERIES NITROUS SYSTEM Catalog Part #70403 T able of Contents Page # a. General Warranty . . . . . . . . . . . . . . .
Page 2 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 Thank Y ou…. …for purchasing an Edelbrock Nitrous Oxide Injection System. Nitrous Oxide injection is one of the most exciting performance enhancements, for the dollar invested, on the market today .
Page 3 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 Caution!! Before Y ou Install Y our Edelbrock Nitrous System… Please read this Installation manual fully before installing this system.
Page 4 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 WHA T IS NITROUS OXIDE? Nitrous Oxide is a cryogenic gas composed of nitrogen and oxygen molecules. It is stored as a “gas over a liquid” which means tha t both liquid and gaseous nitrous oxide is delivered into your engine.
Page 5 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 1.0 Introduction to your Edelbrock 1999-2003 Ford Lightning Performer EFI Nitrous System Within the pages of this manual is information, safety tips and operation instructions for your new Edelbrock Nitrous System.
Page 6 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 1.2 Jet Map Information Edelbrock engineering has conducted dyno testing with the Edelbrock Ford Lightning P erformer EFI Nitrous System to ensure the horsepower increase the nitrous system is as intended.
Page 7 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 1.4 Edelbrock 1999-2003 Ford F-150 Lightning Performer EFI Series Kit Contents QTY .
Page 8 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 2.0 Performer EFI System Installation 2.1 Nitrous Bottle Mounting The nitrous oxide storage cylinder is typically called a “nitrous bottle”. It is an aluminum cylinder , designed and manufactured to withstand very high pressures.
Page 9 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 2.2 Bottle Mounting Instructions Accurate calibration of your nitrous system depends on the bottle remaining a t a stable temperature. Choosing the proper location and orientation for your bottle can grea tly affect the overall operation of the nitrous system.
Page 10 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 2.4 Nitrous Bottle Installation After you have determined the location and orienta tion of the nitrous bottle, use the following procedure to install the bottle: 2.
Page 11 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 2.5 Nitrous Feed Line Mounting 1. Determine the route your main nitrous feed line will follow . Ensure the path does not route the nitrous feed line too close to the exhaust system, suspension, electrical lines/components or tires.
Page 12 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 2.7 Nitrous Spray Nozzle Installation 1. Determine nozzle mounting location in air inlet pipe, between air fil.
Page 13 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 2.8 EFI Vacuum “T ee” Installation 1. Install the recommended jet into the EFI V acuum “T ee” and tighten fitting securely . 2. Remove vacuum line from the vehicle’ s fuel pressure regulator .
Page 14 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 Item # Quantity Description 1 1 ea. Activation microswitch 2 1 ea. Activation microswitch bracket (not shown) 3 2 ea. Activation microswitch mounting nut 4 2 ea.
BA TTERY FUSE RELA Y SOCKET SOCKET SWITCHED +12V ARMING SWITCH SOLENOID SOLENOID FUEL PRESSURE SAFETY SWITCH W ARNING! DO NOT CONNECT TO THIS TERMINAL MICROSWITCH RED WHITE BLACK BLUE RED SUPPL Y +12v ON ACC GROUND - 12 16 11 7 8 11 13 14 9 10 13 2 3 4 1 13 15 13 5 6 (2) (2) (2) (2) ©2002 Edelbrock Corporation Rev .
Page 16 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 3.4 Nitrous Electrical System Installation Procedures Determine the location of the Relay and Fuse Holder wire harness. Most common installations locate these components inside the driver’ s compartment and c lose to the fuse panel under the dash.
Page 17 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 3.6 Arming Switch and Installation The arming switch is a red, lighted switch that is a "MASTER" arming s witch for your nitrous system.
Page 18 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 3.7 Microswitch Installation and Wiring (Continued) The bolts used to attach the microswitch ha ve extra length to allow for spacing the microswitch a way from the bracket if necessary .
Page 19 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 4.0 Before Y ou Run Y our Vehicle Using Y our Edelbrock Nitrous System Y ou ha ve just completed the installation of your Edelbrock Nitrous System.
Page 20 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 5.0 T roubleshooting and Routine Maintenance How to use our T roubleshooting Flo wchart: The troubleshooting of a nitrous system is basic and straightforward. The symptom chart is divided by symptom, cause and action required.
Page 21 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 4. Malfunctioning arming switch. a. With ignition "on", turn arming switch "on." Connect test light to batter y "-" (negative) terminal.
Page 22 of 22 Catalog #70403 Brochure No. 63-0147 ©2003 Edelbrock Corporation Rev . 1/03 3. Spark plug heat range too high. a. Verify what heat range the spark plug is, and how it functions in a high load, high performance application. 1. Install a performance spark plug.
Een belangrijk punt na aankoop van elk apparaat Edelbrock 70403 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Edelbrock 70403 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Edelbrock 70403 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Edelbrock 70403 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Edelbrock 70403 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Edelbrock 70403 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Edelbrock 70403 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Edelbrock 70403 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.