Gebruiksaanwijzing /service van het product VR-CM50 van de fabrikant EFJohnson
Ga naar pagina of 50
VR-CM50 CONSOLE SYSTEM INSTALLATION GUIDE Second Pri nting February 1996 Supersed es 004- 3039-274 May 19 95.
.
VR-CM50 CONSOLE SYSTEM INSTALLATION GUIDE Copyri ght 1995 by t he E.F. John son Compa ny The E.F. J ohnson C ompany des igns and manu factures t wo-way radi o equipmen t to s erve a wide variety of communicat ions needs.
.
T ABLE OF CONTENTS 1 1 PRE-INSTALLATION INFORMATION 1.1 RECEIVING INFORM ATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 VISIBLE LOSS OR DAMAGE . . . . . . . . . .
T ABLE OF CONTENTS (CONT .) 2 4 CRT-BASED ELECTRONICS ASSEMBLY PART I 4.1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.2 INSTALL THE PC/UPS SLIDE TRAY .
T ABLE OF CONTENTS (CONT .) 3 2-14 14 CARD RELAY PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15 2-15 CPP POWER SUPPLY. . . . . . . . . . . . . . . . . . . .
.
1-1 Februar y 1996 Part No. 0 04-3039- 274 PRE-INST A LLA TION INFORMA TION SECTION 1 PRE-INST ALLA TION INFO RMA TION 1.1 RECEIVING INFORMA TION I M P O R T A N T This mer chandise was car efully packed and thor- oughly i nspected bef or e leavi ng our factory .
PRE-INSTALLATION INFO RMATION 1-2 February 19 96 Part No. 0 04-3039- 274 1.1.5 TOOLS REQUIRED The foll owing t ools are n eeded for the mecha ni- cal ass embly an d install ation of the VR-CM50 Co n- .
2-1 Februar y 1996 Part No. 0 04-3039- 274 CENTRAL PROCESSOR P ACKAGE INST ALLA TION SECTION 2 C ENTRAL PROCESSOR P ACKAGE INST ALLA TION 2.1 LOCA TION OF THE CENTRAL PRO CES- SOR P ACKAGE (CPP) In se lecting a loca tion for the Cent ral Proc essor Package ( CPP) equi pment cabi net, th e followi ng crite- ria s h oul d be co nsi der ed : 1.
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-2 February 19 96 Part No. 0 04-3039- 274 Figure 2-1 REAR VIEW - JOINING TWO CPU CABINETS.
CENTRAL PROCESSOR P ACKAGE INSTALLATION 2-3 Februar y 1996 Part No. 0 04-3039- 274 2.3 CONNECTION OF THE CENTRAL PRO- CESSOR P ACKAGE CABLES When mult iple CPP cabine ts are r euired, t he sys- tem layout wi ll have be en designe d to minimiz e the cabling needed bet ween cabine ts.
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-4 February 19 96 Part No. 0 04-3039- 274 2.4 MOUNTING OF SURGE ARRESTOR BOX- ES AND GROUND B RACKET 2.4.1 PLACEMENT OF SURGE ARRESTOR BOXES The sur ge arrestor box(es) may be mount ed direct ly on a wall or on a plywood boar d at a lo cation near th e central equip ment cab inet.
CENTRAL PROCESSOR P ACKAGE INSTALLATION 2-5 Februar y 1996 Part No. 0 04-3039- 274 2.5 GROUNDING THE SYSTEM Proper gr oundin g is the s ingle most important conside ration i n inst alling t he system.
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-6 February 19 96 Part No. 0 04-3039- 274 Figure 2- 5 COMMON GROUND BRACKET ASSEMBL Y placement of the co nnections on the common g round bracket assembly .
CENTRAL PROCESSOR P ACKAGE INSTALLATION 2-7 Februar y 1996 Part No. 0 04-3039- 274 2.7 CPP I/O P ANELS CPPs with a capaci ty of twen ty or more c ards will hav e one or more CPP I/O panels a s shown in Figure 2 -6. If th ere is more than o ne I/O panel , each panel i s numbered.
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-8 February 19 96 Part No. 0 04-3039- 274 2.8 SAMPLE CUSTOMER DA T A SHEETS The Customer Data Sheet s which ar e included in the VR-CM50 Cons ole Servi ce Manual, V olume 1, will d eta il th e conn ect or a nd pa ir as sign men ts fo r all I/O func tions .
CENTRAL PROCESSOR P ACKAGE INSTALLATION 2-9 Februar y 1996 Part No. 0 04-3039- 274 Figure 2-8 RTL I/O P ANEL ASSIGNMENTS Figure 2-9 VOTING COMP ARA TOR DISPLA Y/CONTROL MODULE.
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-10 February 19 96 Part No. 0 04-3039- 274 Figure 2-10 LOGGING RECORDER Figure 2-1 1 AUXILIAR Y CONTROL RELA Y ASSIGNMENTS.
CENTRAL PROCESSOR P ACKAGE INSTALLATION 2-11 Februar y 1996 Part No. 0 04-3039- 274 2.9 WIRING OF SURGE AR RESTOR BOXES T ypically , connect ors P9 through P13 on t he st an- dard I/ O panel (connector s P4 throu gh P6 on 14 card cabinet s) will be a ssigned f or R TL I/O connecto rs.
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-12 February 19 96 Part No. 0 04-3039- 274 2.10 DISP A TCH POSITION CONNECTIONS Each disp atch po sition wi ll plug di rectly i nto the J1 connect or on the PIC line termi nator boa rd as shown in Figur e 2-15.
CENTRAL PROCESSOR P ACKAGE INSTALLATION 2-13 Februar y 1996 Part No. 0 04-3039- 274 T ypically , logging r ecorde r audio ap pears on co n- nector P14 on the sta ndard I/ O panel ( connec tor P7 on 14 card CPP cabinets ).
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-14 February 19 96 Part No. 0 04-3039- 274 relays 9 t hrough 16 mount at the t op of the p anel. The Custome r Data Sheet s whic h are incl uded in th e VR-CM50 Console Service Manu al, V olume 1, will define the re lay panel assignment s for all Auxiliar y I/ O functi ons.
CENTRAL PROCESSOR P ACKAGE INSTALLATION 2-15 Februar y 1996 Part No. 0 04-3039- 274 2.16 CONNECTION TO AUXILIAR Y CONTROL FUNCTIONS (14 Card Central Cabinet) The 14 car d Central Processor can acc ommodate only one Au xiliary Control Relay c ard with a maxi- mum of 16 rel ays.
CENTRAL PROCES SOR PACKAGE INSTALLATION 2-16 February 19 96 Part No. 0 04-3039- 274 2.17 P A SYSTEM FEED The CPP can be connec ted to a bu ilding pu blic address to perm it paging via the di spatch console( s). The consol e(s) must be equippe d with programmin g option TDM-OP4 31 or TDV -OP431 to u se this f ea- ture.
3-1 Februar y 1996 Part No. 0 04-3039- 274 CABINETRY ASSEMBL Y FOR CRT CONSOLE SY STEMS SECTION 3 CAB INETR Y ASSEMBL Y FOR CRT CON SOLE SYSTEMS 3.1 INTRODUCTION This sec tion cont ains the i nstru ctions t o assem- ble VR-CM50 CABINETR Y .
CABINETRY ASSE MBLY FOR CRT CONSOLE SYS TEMS 3-2 February 19 96 Part No. 0 04-3039- 274 3.4 MAIN CONSOLE ASSEM BL Y 4. Remove t he front and r ear keylocke d enclosure pan- els fr om each bay an d set them a side. C A U T I O N Keylocks will scr atch ke ylock enc losur e panels if the y ar e stacked or leaned ag ainst each other .
CABINETRY ASS EMBLY FOR CRT CONSOLE SYSTEMS 3-3 Februar y 1996 Part No. 0 04-3039- 274 Figure 3-4 FORMICA SURF ACE ARRANGEMENT 2. Mark the cons ole face where the brea ks occur in the Formic a writing surface. The ma rks should be made below t he wri ting surf ace plane so that t hey will be hidden when t he Formica i s insta lled.
CABINETRY ASSE MBLY FOR CRT CONSOLE SYS TEMS 3-4 February 19 96 Part No. 0 04-3039- 274 Figure 3-6 WRITING SUPPORT RAIL MO UNTING NOTE: If t he console has a keyboa r d r ecess, a shorter keyboar d support rail is use d in place of a writing support ra il.
CABINETRY ASS EMBLY FOR CRT CONSOLE SYSTEMS 3-5 Februar y 1996 Part No. 0 04-3039- 274 Figure 3-7 CTP TRA Y 3.8 A TT ACHING THE FORMICA WRITING SUR- F ACE 1. Positi on all wri ting s urfac es on the wri ting support rails. 2. Where a split oc curs in t he Formica writing s urface, insert wood bis cuits into the sl ots on the sides of the surfac es.
CABINETRY ASSE MBLY FOR CRT CONSOLE SYS TEMS 3-6 February 19 96 Part No. 0 04-3039- 274 Figure 3-10 FORMICA WRITING SURF ACE AND TRIM Replace a ll keylocked enclosur e panels. Th e standar d mechani cal asse mbly is now comple te. If your cons ole con figurat ion has opt ional equ ipment, PLEASE CONTINUE.
CABINETRY ASS EMBLY FOR CRT CONSOLE SYSTEMS 3-7 Februar y 1996 Part No. 0 04-3039- 274 cabinet ry cons isti ng of a pi e-shap e secti ons al ong with 2 or mo re cab inet bays in-line befor e the tu rn, one (1) stabil izer kit only is r equir ed at the end oppo site the pie-sha ped sec tion.
CABINETRY ASSE MBLY FOR CRT CONSOLE SYS TEMS 3-8 February 19 96 Part No. 0 04-3039- 274 3.10.4 UNIVERSAL PENCIL DRA WER MOUNT- ING (O PTION 4) 1. Remove t he penci l drawer from the mountin g frame by de pressing the b lack sli de re tainers . Refer to Fig- ure 3-14 .
CABINETRY ASS EMBLY FOR CRT CONSOLE SYSTEMS 3-9 Februar y 1996 Part No. 0 04-3039- 274 Figure 3-16 PIE SUPPORT RAIL MOUNTING 3.10.7 CRT MONIT O R SHELF - FXM-192 (OP- TION 7) The hardwa re in T able 3-1 is inc luded with the Monito r Shelf assemb ly (FXM- 192): 1.
CABINETRY ASSE MBLY FOR CRT CONSOLE SYS TEMS 3-10 February 19 96 Part No. 0 04-3039- 274 Figure 3-18 CRT MONIT OR SHELF T able 3- 1 MONIT OR SHELF HARDW ARE Qty .
4-1 Februar y 1996 Part No. 0 04-3039- 274 CRT -BAS ED ELEC TRONICS ASSEMBL Y P A RT I SECTION 4 CRT -BASED ELECTRONICS ASSEMBL Y P ART I 4.1 INTRODUCTION Since you have purch ased the E.
CRT-BASED ELECTRONI CS ASSEM BLY PART I 4-2 February 19 96 Part No. 0 04-3039- 274 Figure 4-2 CIP POWER SUPPL Y Mount The CIP T ray Insta ll th e CI P tray at the lo ca tion i ndi cated in the Customer Spec if icat ion s Documen tation or as per th e customer s prefer ence.
CRT-BASED ELE CTRONICS ASSE MBLY PA RT I 4-3 Februar y 1996 Part No. 0 04-3039- 274 Figure 4- 3 CIP TRA Y WITH MICROPHONE 3. After t he CIP tray is mounted, conn ect the f ollow- ing cabl es using T able 4-5. 4. Mount the p anel micro phone (TDV -OP402/HR) to the C IP : All othe r microphon e options, i.
CRT-BASED ELECTRONI CS ASSEM BLY PART I 4-4 February 19 96 Part No. 0 04-3039- 274 This pag e inte ntionall y left blan k..
5-1 Februar y 1996 Part No. 0 04-3039- 274 CRT -BAS ED ELECTRONICS ASSEMBL Y P AR T II SECTION 5 CRT -BA SED ELECTRONICS ASSEMBL Y P ART II 5.1 INTRODUCTION If you ha ve or der ed a CR T -Based console sys tem instal led in E.F . JOHNSON cabinet ry , most of the assembly will alr eady have b een done at the fa ctory .
CRT-BASED ELECTRONI CS ASSEM BLY PART II 5-2 February 19 96 Part No. 0 04-3039- 274 5.4 CONNECT THE CRT I NTERF AC E PROCESSOR (CIP) TRA Y CABLES Refer t o Figure 5- 2 and T able 5- 2.
CRT-BASED ELE CTRONICS ASSEMBLY PAR T II 5-3 Februar y 1996 Part No. 0 04-3039- 274 5.5 INST ALL THE CRT MONIT OR 5.5.1 CRT MONITOR CONNECTIONS Refer to Fi gure 5-1. 1. Plug the female end of the IEC cord into the CR T monitor . 2. Plug the other end of the IEC cord into the 2 nd top outlet on the PC UPS.
CRT-BASED ELECTRONI CS ASSEM BLY PART II 5-4 February 19 96 Part No. 0 04-3039- 274 5.7 INST ALL CRT TRACKBALL OP TION/ MOUSE OPTION TRACKBALL OP TION - TDV -OP490 MOUSE OP TION - TDV -OP491 Plug the DE9-M connecto r into the PC CPU (COM 2) Mouse/T rackball DIN.
CRT-BASED ELE CTRONICS ASSEMBLY PAR T II 5-5 Februar y 1996 Part No. 0 04-3039- 274 1. Remove th e hole plug from the le ft side of the head- set ja ck housing. 2. Instal l the vol ume contr ol (475190 4Z5001) in t he housing i n the p lace of t he hole pl ug.
CRT-BASED ELECTRONI CS ASSEM BLY PART II 5-6 February 19 96 Part No. 0 04-3039- 274 This pag e inte ntionall y left blan k..
6-1 Februar y 1996 Part No. 0 04-3039- 274 EQUIPMENT CHECK-OUT AND AD JUSTMENTS SECTION 6 EQUIPMENT C HECK-OUT AN D ADJU STMENTS 6.1 INITIAL POWER-UP AND CHECK-OUT I M P O R T A N T Be sur e AC power is avail able a t the outl ets.
EQUIPMENT CHECK-OUT AND A DJUSTMENTS 6-2 February 19 96 Part No. 0 04-3039- 274 7. Observe the LEDs on the channel modu les. On module-ba sed con soles, eac h channe l module should ha ve either t he yellow or green LED adj a- cent to the volume c ontrol on.
EQUIPMENT CHE CK-OUT AND ADJUSTM ENTS 6-3 Februar y 1996 Part No. 0 04-3039- 274 Headset Rec eive Limit The rece ive aud io sensit ivity an d the method of handlin g audi o over load v aries widel y among heads et manufact urers.
EQUIPMENT CHECK-OUT AND A DJUSTMENTS 6-4 February 19 96 Part No. 0 04-3039- 274 SCREEN 1 _____________ _________ ______________ _____________ ______________ _________ ______________ TO UCH THE UPPER L.
Een belangrijk punt na aankoop van elk apparaat EFJohnson VR-CM50 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen EFJohnson VR-CM50 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens EFJohnson VR-CM50 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding EFJohnson VR-CM50 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over EFJohnson VR-CM50 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van EFJohnson VR-CM50 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de EFJohnson VR-CM50 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met EFJohnson VR-CM50 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.