17 16 4 3 5 6 2 1 7 8 9 10 11 12 13 14 15 Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up and Programming and Programming and Programming and Programming and Programming Premium options to customize the thermosta t to fit your applica tion.
1 INTR ODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Y our new White-Rodgers thermostat uses solid state micro- computer technology to provide precise time/tempera- ture control. This thermostat offers the fle xibility to design heating and cooling programs that fit your needs.
2 THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS See inside front cov er for illustration showing button locations.
3 FAN AUTO HRS CHECK BATTERY STAT SYSTEM ° F AM MON PRG FAN ON HEAT HEAT HRS CHECK BATTERY ° F AM MON WED THU FRI SAT SUN TUE WED THU FRI SAT SUN TUE 18 18 19 20 21 21 22 25 23 24 Figure 1.
4 INST ALLA TION 1F92-371 : 5/2 Day programming; residential applications ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA Electrical Rating: 20 to 30 V A C, 50/60 Hz with common 0.05 to 1.5 Amps per terminal 2.5 Amps maximum total load (all terminals combined) Standard Systems: Multi-stage gas, oil, electric.
5 Installation PRECAUTIONS PRECAUTIONS PRECAUTIONS PRECAUTIONS PRECAUTIONS ▲ ! WARNING WARNING WARNING WARNING WARNING Do not shor t out ter minals on gas valv e or primar y control to test. Shor t or incor rect wiring will damage ther mostat and could cause personal injur y and/or proper ty damage .
6 ATTENTION! ATTENTION! ATTENTION! ATTENTION! ATTENTION! This product does not contain mercury . Howe ver, this product may replace a unit which contains mercury . Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury .
7 Installation Insert the wires into the terminals on the base using the appropriate wiring diagram and tighten the terminal screws. CONFIGURING CONFIGURING CONFIGURING CONFIGURING CONFIGURING AND PRO.
8 MULTI-STAGE TERMINAL OUTPUTS MULTI-STAGE TERMINAL OUTPUTS MULTI-STAGE TERMINAL OUTPUTS MULTI-STAGE TERMINAL OUTPUTS MULTI-STAGE TERMINAL OUTPUTS Refer to equipment manufacturers’ instructions for specific system wiring information.
9 Installation HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS Refer to equipment manufacturers’ instructions for specific system wiring information. Y ou can configure the thermostat for use with the following heat pump system types: HEA T PUMP TYPE 1.
10 HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS HEAT PUMP TERMINAL OUTPUTS THERMOSTAT TERMINALS (Lower) THERMOSTAT TERMINALS (Lower) THER.
11 THERMOSTAT TERMINALS (Lower) THERMOSTAT TERMINALS (Lower) THERMOSTAT TERMINALS (Lower) THERMOSTAT TERMINALS (Lower) THERMOSTAT TERMINALS (Lower) SY STEM E C R W3/A1 W2 E2/P W1 Y2 Y1 B O G System re.
12 CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION RESET SWITCH RESET SWITCH RESET SWITCH RESET SWITCH RESET SWITCH See the T roubleshooting section at the end of this document for more information about the function of this switch.
13 Installation INSTALLER CONFIGURATION INSTALLER CONFIGURATION INSTALLER CONFIGURATION INSTALLER CONFIGURATION INSTALLER CONFIGURATION BEFORE TURNING POWER ON, please read the f ollowing instructions. Befor e operating the system, you must conf igure the thermostat to operate properly with your equipment.
14 INSTALLER CONFIGURATION (cont.) INSTALLER CONFIGURATION (cont.) INSTALLER CONFIGURATION (cont.) INSTALLER CONFIGURATION (cont.) INSTALLER CONFIGURATION (cont.) T o exit the menu at an y time, press PROGRAM RUN . MULTI-STAGE/HEAT PUMP MULTI-STAGE/HEAT PUMP MULTI-STAGE/HEAT PUMP MULTI-STAGE/HEAT PUMP MULTI-STAGE/HEAT PUMP MODE.
15 Installation this digital thermostat. As config- ured at the factory , this thermostat will maintain an accurate tempera- ture. No further adjustment is necessary , although you can use these menu items to customize the performance of the thermostat to your requirements.
16 1 ML TI STG HEA T PUMP 2 HEA T PUMP (1) 2 or 3 Selects type of system. Selecting HEA T PUMP makes additional menu items for heat pump system av ailable. 3 ELECT HEA T F AN (ON) OFF Fan cycles with call for heat if ON. F an always cycles with pump stages.
17 12 ECON (OFF) ON Returns to normal operation. 13 HEA T -OFF-COOL-AUT O or HEA T -EMER-OFF-COOL- A UT O (for heat pumps) HEA T -OFF-COOL or HEA T -EMER-OFF-COOL (for heat pumps) Allows selection of HEA T and COOL or HEA T , COOL and A UTO with SYSTEM button.
18 PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE COOL FAN-OFF AND COOL FAN-OFF AND COOL FAN-OFF AND COOL FAN-OFF AND COOL FAN-OFF AND FAN-ON DELAY. FAN-ON DELAY. FAN-ON DELAY. FAN-ON DELAY. FAN-ON DELAY. (Installer table steps 7 and 8.
19 Installation using this feature instead of a kit. This item will allow the thermostat to turn the heat pump compressor of f if the auxiliary is on for more than one minute, to prev ent compressor head pressure from getting too high. T o use this feature instead of a kit, select PUMP OFF .
20 DISABLING AUTOMATIC DISABLING AUTOMATIC DISABLING AUTOMATIC DISABLING AUTOMATIC DISABLING AUTOMATIC CHANGEOVER MODE. CHANGEOVER MODE. CHANGEOVER MODE.
21 CAUTION ! COOLING SYSTEM COOLING SYSTEM COOLING SYSTEM COOLING SYSTEM COOLING SYSTEM T o prevent compr essor and/or property damage, if the outdoor temperature is below 50°F (10°C), DO NOT operate the cooling system. 1. Press PR OGRAM RUN . 2. Press SYSTEM until COOL COOL COOL COOL COOL is displayed.
22 TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING RESET BUTTON RESET BUTTON RESET BUTTON RESET BUTTON RESET BUTTON If the thermostat does not respond when keys are pressed, or the thermostat is not operating properly , you may use the reset button located on the back of the thermostat body (see fig.
23 The configuration menus allo w you to set certain thermostat operating characteristics to your system or personal requirements. T o enter the User Configuration menu, press PROGRAM RUN to make sure the thermostat is in the run program mode, then press TIME FWD and TIME BACK at the same time.
24 1 Step Press Button(s) Displayed Press or to select: COMMENTS Ref (Factory Default) Page 0˚F (room temperature) 5 LO to 5 HI 2 EMR (ON) OFF or ON L Adjusts temperature display higher or lower .
25 1 Step Pr ess Button(s) Displayed Press or to select: COMMENTS Ref (Factory Default) Page P ART LOCK (OFF) ON 2 LOCK (OFF) ON Partial Keypad lockout OFF or ON.
26 PR OGRAMMING MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION Y our Comfort-Set 90 thermostat can be used to control temperature manually (without programming). For manual operation, press SYSTEM to select HEAT HEAT HEAT HEAT HEAT or COOL COOL COOL COOL COOL , then press PROGRAM HOLD .
27 Programming 9. Press TIME FWD or TIME BACK to set the time on the display as selected in your HEA TING or COOLING SCHEDULE. Be sure to check the AM or PM on the display . 10. Press the red or blue ke y to adjust the temperature to match your schedule.
28 5/2 Day Sample Program Schedule (Shows factory programming) MORNING (MOR) D A Y (D A Y) EVENING (EVE) NIGHT (NHT) 6:00 AM 8:00 AM 5:00 PM 10:00 PM 70 F (21 C) 62 F (17 C) 70 F (21 C) 62 F (17 C) 6:.
29 5/2 Day Personal Program Schedule MORNING (MOR) D A Y (D A Y) EVENING (EVE) NIGHT (NHT) Star t Time T emperature Star t Time T emperature 5-D A Y 2-D A Y MORNING (MOR) D A Y (D A Y) EVENING (EVE) N.
30 FEA TURES CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION MENU FEATURES MENU FEATURES MENU FEATURES MENU FEATURES MENU FEATURES Adjustable Temperature Adjustable Temperature Adjustable Temperature Adjustable Temperature Adjustable Temperature Display.
31 applications start earlier because it takes longer to reach the desired temperature. This feature also minimizes the use of the auxiliary stages if conditions are such that the compressor stages are adequate to reach the desired setpoint. T o select or deselect this feature, refer to the CONFIGURA TION section (page 24, item 2).
32 Keypad Lockout. Keypad Lockout. Keypad Lockout. Keypad Lockout. Keypad Lockout. (Keypad Lockout table) This security feature allows you to lock out the keypad to pre vent unautho- rized tampering with the program. T wo le vels of security are a vailable, T otal K eypad Lockout or P artial K eypad Lockout.
33 the programming examples section lists these factory settings. If the times and temperatures are the same as your schedule, you may simply run the factory installed program by pressing PROGRAM RUN . Compressor Short-Cycle Compressor Short-Cycle Compressor Short-Cycle Compressor Short-Cycle Compressor Short-Cycle Protection.
34 feature. Change to the next program period and press the FA N key until PR PR PR PR PR G F G F G F G F G F AN ON AN ON AN ON AN ON AN ON is on the display . The fan will continue to run through this period as well as the previous one. If the thermostat is in a period with continuous fan and you want the fan to cycle, press the FA N ke y .
35 thermostat will quit calling for heat for one minute (this allows some furnaces to reset) and call for heat again. It will repeat this sequence three times. If the temperature still does not rise, it will continue to call for heat. This normally indicates the heating system is not working correctly .
36 without a program running, press PROGRAM HOLD . The or ke ys can be used to raise or lower the temperature. The thermostat will hold the set temperature until you return to the program by pressing PR OGRAM RUN .
37 press PROGRAM RUN to resume your normal program. Large Lighted Liquid Crystal Large Lighted Liquid Crystal Large Lighted Liquid Crystal Large Lighted Liquid Crystal Large Lighted Liquid Crystal Display (LCD). Display (LCD). Display (LCD). Display (LCD).
38 previously set program. After a power loss, the remote sensors will be operating properly , how eve r , temperature at the remote sensors can not be displayed until PROGRAM RUN is pressed. Second Stage Time Delay. Second Stage Time Delay. Second Stage Time Delay.
39 Program Entering Y our ------------------- 26 Planning Y our ------------------ 26 T emporary Ov erride ----------- 35 PROGRAMMING --------------- 26 Schedule Sample Program --------------- 28 Pers.
NO TES.
NO TES.
PART NO. 37-6422C Replaces 37-6422B 0513 The Emerson logo is a trademark and a service mark of Emerson Electric Co. White-Rodg ers is a division of Emerson Electric Co.
Een belangrijk punt na aankoop van elk apparaat Emerson 1F92 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson 1F92 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson 1F92 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson 1F92 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson 1F92 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson 1F92 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson 1F92 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson 1F92 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.