381333–136 C 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, .
SECT ION 1 INST ALLA TION 1 --- 1 The ASCO 7000 Se ries A ut omatic Closed–T ransiti on T ransfer & Bypass–Isolation Switch ( ACTB) consists of an upper bypass–i solatio n sw it ch, a transfer swit ch, a monitoring and transfer control ler, and door–mounted controls.
INST ALLA TION (cont inued) 1 --- 2 De–energ ize the conductors b efo re m aking a ny line or a uxiliary circuitry co nnections. Be sure that Norma l and Emergency line co nnections are in prop er phase rota tion. Pla ce engine gen - erator sta rting control in the OFF position.
INST ALLATIO N (continued) 1 --- 3 RED RED GREEN GREEN obse rve these li ghts RED RED RED Figure 1- 3. Standard controls and i ndicators. F unctio nal T est R ead all instruc tions on the W irin g Diagrams and label s affi xed to t he A CT B. Note the control features tha t are provided and r eview their operation before pro ceeding.
INST ALLA TION (cont inued) 1 --- 4 RED RED GREEN GREEN obse rve these li ghts RED RED RED oper at e this s w itch Figure 1- 4. Standard controls and i ndicators. 2 – Electrica l Op eratio n Th i s pro ced ur e che cks e le ctr i cal op er at i on o f t he A T S.
SECT ION 2 TEST ING & SERVICE 2- -1 TRA NS FE R TEST T est the A utom atic Closed –T ran sition T ransf er Switc h portion of t he 7000 Series ACTB at least once a month. This proc edure chec ks the elec trical oper ation of the T ransfer Switc h and Control P anel.
TEST ING & SERVICE (continued) 2- -2 TROUBL E-SHOOTING Note any opti onal accessories that may be furnished on the ACTB and review their operation. R efer to any sepa- rate draw ings an d/or instr uction s that may be p acked with the A CTB. T abl e 2-1.
SECTION 3 B YP ASS ING & ISOLA TING 3 --- 1 BY PA S S I N G T H E A T S * This pr ocedu re expl ains h ow to Byp ass the c los ed autom atic transfer sw itch contac ts.
B YP AS SING & ISOLA TING (continued) 3 --- 2 ISOLATING THE A TS Isolating is required before any service work can be perform ed on the automatic trans fer switch ( A TS). R efer to Figures 3–4, 3–5, 3–6, and 3–7. 1. Bypass t he closed automatic trans fer switch c ontacts.
B YP AS SING & ISOLA TING (continued) 3 --- 3 RETURN TO SERVI CE This proc edure explain s how to r eturn the automatic tr an sf er s wi tch ( A T S ) to s er vi ce a f te r i ns pe cti o n and maintena nce. Observe t he Byp ass Sw itch P osition in dica- tor and lights).
B YP AS SING & ISOLA TING (continued) 3 --- 4 RETURN TO SERVI CE cont inued* This proc edure exp lains how to return the Bypass Switc h Hand le to the OPEN position . Th e Bypass Handl e must be i n the CLOSED positi on (yellow indicator on NOR - MAL or EMERGENCY ) and the Is olation Handl e must be in t he TEST posi tion (window).
INDEX Printed in U .S.A . Copy right ASCO Power T echnologies, L.P . 2007 A Alarm R eset pushbutton, 1–4, 2–2 auxil iary cir cuits, 1 –2 B bus connections, 1–2 bypassing t he A TS, 3–1 C cat.
Een belangrijk punt na aankoop van elk apparaat Emerson 7ACTB (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson 7ACTB heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson 7ACTB vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson 7ACTB leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson 7ACTB krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson 7ACTB bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson 7ACTB kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson 7ACTB . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.