READ AND SA VE THESE INSTRUCTIONS Part No. F40BP73500000 Form No. BP7350 U.L. Model No.: CF3200 Net Weight: 26.0 Lbs. Model Numbers B A T ON R OUGE ™ Ceiling F an Owner's Manual CF3200AWL00 Sum.
2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2.
3 This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan One stepladder One wire stripper One Phillips head screwdriver Four 15-watt (max.) candelabra base bulbs MA TERIALS Wiring outlet box and box connectors must be of type required by the local code.
1. Place the flange assembly onto the bottom of the blade assembly. Place the flange medallion assembly into the four holes of the blade assembly. 2. Secure the flange assembly and flange medallion to the blade assembly using the four #10-32 x 10mm pan head screws.
7. Remove the wire connector from the white wire of the switch housing plate. Retain for the next step. 8. Connect the white wire from the switch housing plate to the white wire of the switch housing, using the wire connector previously removed (Figure 3).
6 YELLOW FAN WIRE ONE-PIN CONNECTOR LIGHT KIT ASSEMBL Y WHITE LIGHT KIT ASSEMBL Y WIRE WHITE FAN WIRE YELLOW LIGHT KIT ASSEMBL Y WIRE Figure 8 15-WA TT CANDELABRA BASE LIGHT BULB (4) LIGHT KIT ASSEMBL Y SOCKET (4) Figure 9 15. Securely connect the white fan one-pin connector wire to the white one-pin connector wire from the light kit assembly.
7 DOWNROD HAIRPIN CLIP CLEVIS PIN SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP MOTOR COUPLING Figure 12 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
8 28. The blue, black, white, and yellow leads exiting the downrod are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
9 Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
1-1/4" THREADED STUD (2) CEILING COVER KNURLED KNOB (2) LOCKWASHER (2) 1-1/4" THREADED STUDS (2) HANGER BRACKET OUTLET BOX RECEIVER CEILING COVER Figure 25 WHITE SUPPL Y WIRE BLACK FAN WIRE .
The SW116 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW116 wall control to function. Power for the SW116 wall control comes from the 12V battery, located in the wall control.
Operating Y our Ceiling F an IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. NOTE: The downlight button will not work unless an Emerson light kit is added to the ceiling fan.
13 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan.
14 3 10 11 2 1 9 6 31 32 18 10 11 9 5 9 4 8 7 8 33 34 17 19 20 22 23 28 13 14 15 16 BLADE 10-32 x 10mm PAN HEAD SCREW (4 Per Blade) FLANGE ASSEMBL Y FLANGE MEDALLION 26 24 21 12 25 27 29 30 H I H I M E D M E D L O W L O W F A N O F F R E V R E V L I G H T 34 R epair Par ts U.
15 R epair Par ts Listing Key Model No. N o. Description CF3200AWL00 CF3200DBZ00 * Hanger Pack, Consisting of: 761655-69 761655-68 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod - 12” — — * Parts Bag Containing: 763463-1 763463 4 Pin, Clevis (1) — — 5 Clip, Hairpin (1) — — 6 Wire Connector, 12 Ga.
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Printed in China 11/07 Form No. BP7350 Part No. F40BP73500000 U.L. Model No.: CF3200 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co.
Een belangrijk punt na aankoop van elk apparaat Emerson CF3200AWL00 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson CF3200AWL00 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson CF3200AWL00 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson CF3200AWL00 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson CF3200AWL00 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson CF3200AWL00 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson CF3200AWL00 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson CF3200AWL00 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.