Functional Safety Manual M310/FSM , Rev AA January 2012 Horizontal Float Switch www .mobrey .com Mobrey Magnetic Level Switches Functional Safety Manual.
.
2 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch Content s Introduction Scope and Purpose of the Safety Manual .............. ................ ................. ............ page 3 Skill Level Requirement ........... ..
3 Functional Safety Manual IP101/FSM, Rev AA January 2012 Horizontal Float Switch Magnetic Level Switch Functional Safety Manual INTRODUCTION Scope and Purpose of the Safety Manual This safety manual contains the information to desi gn, install, verify and maintain a Safety Instrumented Function (SIF) utiliz ing the Mobrey magne tic level switch.
4 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch FIT FIT is the abbreviation for Failure In Time. One FIT is 1x10 -9 failure per hour FMEDA Failure Modes, Effects, and Diagnostics Analysis.
5 Functional Safety Manual IP101/FSM, Rev AA January 2012 Horizontal Float Switch Document ation and St andards This section lists the documentation and st andards referred to by this safety manual.
6 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch PRODUCT DESCRIPTION Level Switch Purpose Mobrey magnetic level switches are ideal fo r high and low liquid level alarm, overfill alarm, and pump co ntrol duties. Figure 1.
7 Functional Safety Manual IP101/FSM, Rev AA January 2012 Horizontal Float Switch Figure 3. Level Increases – Float Pivots Upwards NOTE: For all product information and docume ntation downloads, visit www .
8 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch DESIGNING A SAFETY FUNCTION USING THE LEVEL SWITCH Safety Function A change in liquid level through the operating ran ge of the float causes the switch to operate. It may be used in high level or low level safety related appl ications.
9 Functional Safety Manual IP101/FSM, Rev AA January 2012 Horizontal Float Switch SIL Cap ability Systematic Integrity The Mobrey level switch has met manufacturer design process requi rements of Safety Integrity Level 2 (SIL 2). These ar e intended to achieve sufficient integrity against systematic errors of design by the manufacturer .
10 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch Connection of the Level Switch to the SIS Log ic Solver The Mobrey level switch should be connect ed to th e safety-ra.
11 Functional Safety Manual IP101/FSM, Rev AA January 2012 Horizontal Float Switch OPERATION AND MAINTENANCE Proof-test Requirement During operation, a low-de mand mode SIF mu st be proo f-tested. The objec tive of proof-testing is to detect failures within t he equipment in the SIF that are not dete cted by any automatic diagnostics of the system.
12 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch SPECIFICATIONS Useful Life USEFUL LIFETIME According to Section 7.4.9.
13 Functional Safety Manual IP101/FSM, Rev AA January 2012 Horizontal Float Switch PROPOSED PROOF-TEST PROCEDURE According to Section 7.4.3.2.2 (f) of th e standard IEC 6 1508-2, proof-tests shall be undertaken to reveal dangerous faults which are undetected by diagnostic tests.
14 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch LEVEL SWITCHES CERTIFIED TO IEC 61508 T ables 9, 10, and 1 1 lists all of the Mobr ey magnetic level switch options that are certified to IEC 61508.
15 Functional Safety Manual IP101/FSM, Rev AA January 2012 Horizontal Float Switch T able 10. Level Switches fo r General Pur pose Applications (Aluminum Bronze Wetside) T able 1 1.
M310/FSM Rev AA 01/12 Functional Safety Manual M310/FSM, Rev AA January 2012 Horizontal Float Switch © 2012 Mobrey Ltd. All rights reserved. International: Emerson Pr ocess Management Mobrey Ltd. 158 Edinburgh Avenue Slough, Berks , SL1 4UE , UK T +44 (0)1753 756600 F +44 (0)1753 823589 www .
Een belangrijk punt na aankoop van elk apparaat Emerson Process Management M310/FSM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson Process Management M310/FSM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson Process Management M310/FSM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson Process Management M310/FSM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson Process Management M310/FSM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson Process Management M310/FSM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson Process Management M310/FSM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson Process Management M310/FSM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.