INSTALLATI ON GUIDE (v. 2.1).
.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 3 / 23 < Read c arefully before proc eeding with the lecture o f this manual > WARNING: Use only modems support ed by this monitoring unit. Dixell S. r. l. can accept no responsibili ty for possible dam age due the usage of not supported modems.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 4 / 23 Cont ents 1. CHECK L IST ................................ ............................................................... 5 2. RS4 85 CONNE CTION ............................
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 5 / 23 1. CHECK LIS T Before opening packa ge pl eas e check it to be i ntac t an d tit does not s how cras hes or a lteration marks. In the packag ing you sh all find: XWEB [1].
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 6 / 23 2. RS485 CO N NECTI ON To be connected to the seri al line all the Dixell Modbus instruments must be provided with d irect RS48 5 terminals or the “TTL”-RS48 5 i nterfac e (XJRS485 or XJ485).
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 7 / 23 Wrong connection Always keep t he serial cable away from p ower cab les. Always keep t he serial cable away from E lectro -magnetic or frequ ency sources. Do no t connect shield to ground .
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 8 / 23 The TTL ou t pu t The i nstru ment wi th RS48 5 on board does not need any kind of external interface module. For instruments with an external interface: keep the TTL cable away from p ower c ables or frequenc y sou rces.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 9 / 23 3. MODEM C ONNECTI ON (“or poi nt t o point conn ection ” ) It represents the most common metho d where the LAN (intranet / E thernet / internet) is no t available. It is stron gly advi sed t o use a dedicat ed t elephone line.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 10 / 23.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 11 / 23 2. I f Control Pane l i s set for "Classi c View", double-click on the Network Connections icon.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 12 / 23 4. Under Network Tasks, select " Create a new connection"..
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 13 / 23 5. Cli ck "Next" ..
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 14 / 23 6. Cli ck " Next" at t he bottom of this page to c ont inue with the setup instruct ions. 7. Select "Connect to the Internet" and click " Next".
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 15 / 23 9. Select "Connect using a dialup modem" and c lick "Next" .
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 16 / 23 11. Type the access number in the Phone Number box. E.G: If telephone number i s 555789 and area code is 099 , put this Telephone number: 09955578 9.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 17 / 23 12. Type dia lup acco unt name d i xell i n the U ser Name box. Type dialup password dixell in the P ass word and Confirm P as swor d boxes. We rec ommend that you check the fi rst 2 checkboxes, but not the 3rd box w hich turns on the Internet Connec tion F irewall.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 18 / 23 14. You are now ready to connect to your XWEB 500. I f you want to dial your XWEB 500 DIRECT MODEM connec tion automatically when you start Internet Explorer, do the following.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 19 / 23 4. INTRANE T/ETHER NET CONN ECTI ON The Intranet or Eth ernet co nnection should be initially managed by the net administrator w hich will assign one free I P address t o reach the Server.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 20 / 23 5. INTER NET C ONNECTIO N It is necessar y to have a ST ATIC IP address for the XWEB 500 which is normally assigned by the Provider of your internet services (ISP). The Internet connection allows XWEB to be reached from all PC-client s.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 21 / 23 ALWAYS: ask qua l ified personnel for the router in stal lation by usi n g this information.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 22 / 23 6. TROUBLESH OOTING GUIDE Problem Solution The log-in page doesn’ t load Check your browser setu p. My password doesn’ t al low me to log-in. Beware t o the caps-lock button an capitol letters.
1592028150 XWEB3 00D_500_500 D stp GB r2.1 201 2.06.22.doc X W EB50 0 23 / 23 7. UNIT SE TUP RE MINDER Please take some moments to make an handcopy of t his page, then compile i t and sto re it near XWEB unit.
Een belangrijk punt na aankoop van elk apparaat Emerson XWEB300 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson XWEB300 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson XWEB300 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson XWEB300 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson XWEB300 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson XWEB300 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson XWEB300 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson XWEB300 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.