Gebruiksaanwijzing /service van het product MHIR20LPT van de fabrikant Enerco
Ga naar pagina of 24
Installation instructions and Owner’s Manual 1 UNVENTED LP-GAS FIRED ROOM HEA TER Blue Flame Heaters Plaque Heaters Model # Burn Rate Model # Burn Rate MHBF10LP/TSBF10LP 10,000 Btu/hr MHIR10LP/TSIR1.
2 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate.
Installation instructions and Owner’s Manual 3 Product Features Figure 1 SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensor (ODS) safety shut off system. The ODS/pilot shut s off the heater if there is not enough fresh air . IGNITION SYSTEM PIEZO: BF10LP/ IR10LP – The heater is equipped with a piezo manual ignitor .
4 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 *Adjoining rooms are communication only if there are doorless passageways or ventilation grills between them. DETERMINING THE TYPE OF HEA TER LOCA TION SP ACE: Use this method to determine if you have a confined or unconfined space.
Installation instructions and Owner’s Manual 5 Figure 3. V entilation from Outdoors If necessary provide extra fresh air by using ventilation grills or ducts. Connect these items directly to the outdoors or sp aces open to the out doors. These include attics* and crawl spaces.
6 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 Figure 4 F ASTENING HEA TER TO W ALL Mounting Bracket The mounting bracket in located on the back panel of heater (see figure 5). It has been taped there for ship- ping. Remove mounting bracket from back panel.
Installation instructions and Owner’s Manual 7 1. Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep. 2. Fold wall anchor as shown in figure 8 below . Figure 8. 3. Insert wall anchor (wings first) into hole.
8 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 W ARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator . Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.
Installation instructions and Owner’s Manual 9 Pressure T esting Heater Gas Connections: 1. Make sure that the heater supply piping system is connected and has been leak tested as described above. 2. Make sure control knob of heater is in OFF position.
10 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 C. Use only your hand to push in or turn the gas control knob. Never use tools. It knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician or gas supplier .
Installation instructions and Owner’s Manual 11 TO TURN OFF GAS T O APPLIANCE SHUTTING OFF HEA TER: 1. T urn control knob clockwise to the OFF posi- tion. 2. T urn of f all electrical power to the appliance if servicing is to be preformed. 3. T urn of f equipment shutoff valve.
12 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 8. When the pilot is lit, turn control know counter- clockwise to heating level. The main burner should light. 9. T o select the desired heat level, turn the tem- perature setting knob counterclockwise to between 1 & 7.
Installation instructions and Owner’s Manual 13 Figure 24b CLEANING AND MAINTENANCE W ARNING: T urn off heater and let cool before servicing. CAUTION: Y ou must keep control areas, burner and circulation air passageways of heater clean. Inspect these areas of heater before use.
14 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 TROUBLESHOOTING NOTE: All troubleshooting items are listed in order of operation and likely occurrence. W ARNING: Only a qualified service person should service and repair heater . CAUTION: Never use a wire needle, or similar object to clean ODS/pilot.
Installation instructions and Owner’s Manual 15 TROUBLESHOOTING W ARNING: If you smell gas: • Shut off gas supply • Do not try to light any appliance • Do not touch any electrical switch; do not use any phone in your building • Immediately call you gas supplier from a neighbor ’s phone.
16 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 SPECIFICA TIONS IR10 LP IR20LPT IR30LPT BTU (Available) 10,000 20,000 30,000 T ype of Gas LP-Gas Only LP-Gas Only LP-Gas Only Ignit.
Installation instructions and Owner’s Manual 17 REPLACEMENT P ARTS Note: use only original replacement part s. This will protect you warranty coverage for p arts replaced under warranty . P ARTS UNDER W ARRANTY Contact authorized dealer from whom you purchased this product.
18 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 Thermostat models MHIR20LPT , MHIR30LPT , MHBF20LPT , MHBF30LPT TSIR20LPT , TSIR30LPT , TSBF20LPT , TSBF30LPT 7 2 20-2 36 39 38 35 .
Installation instructions and Owner’s Manual 19 P ARTS LIST Thermostat models MHIR20LPT , MHIR30LPT , MHBF20LPT , MHBF30LPT TSIR20LPT , TSIR30LPT , TSBF20LPT , TSBF30LPT This list contains replacement p arts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on p age 17 of this manual.
20 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 28-1 70361 — — — Orifice, 20, IR 3 28-2 — 70362 — — Orifice, 20, BF 1 29 70683 70683 70683 70683 Fan 1 30 70684 70684 7.
Installation instructions and Owner’s Manual 21 NON-Thermostat models MHIR10LP , MHBF10LP TSIR10LP , TSBF10LP 33-1 22-1 1-1 3-1 3-3 3-2 3-6 3-5 26 7 8 23 24 13 1-4 1-2 1-3 6 15 14 42 5 22-3 22-2 20-.
22 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 P ARTS LIST Non-Thermostat model MHIR10LP , MHBF10LP , TSIR10 LP , TSBF10LP This list contains replacement p arts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual.
Installation instructions and Owner’s Manual 23 36 70336 --- Bracket, Botto m, Plenum Assembly 1 38 70677 --- Burner Plaques, 10 2 40 70678 --- Plaque Gasket, 10 2 42 70337 70337 Control V alve Knob.
24 Installation instructions and Owner’s Manual 70575 Rev . C 8/05 W ARRANTY INFORMA TION Keep this warranty Model ______________________ Serial No. ___________________ Date Purchased _______________ Always specify model and serial numbers when communication with the factory .
Een belangrijk punt na aankoop van elk apparaat Enerco MHIR20LPT (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enerco MHIR20LPT heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enerco MHIR20LPT vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enerco MHIR20LPT leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enerco MHIR20LPT krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enerco MHIR20LPT bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enerco MHIR20LPT kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enerco MHIR20LPT . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.