Gebruiksaanwijzing /service van het product MHU 75 van de fabrikant Enerco
Ga naar pagina of 16
0 3/05 Revision L1 #60 0 1 6 ENE R CO GR OUP , INC., 4560 W . 1 60TH ST., CLEV EL AND, OHIO 4 4 1 3 5 • 2 1 6- 916 -3 0 00 READ INSTRUC TIONS C AREFULL Y: R ead and f ollow all instructions. Pla ce instructions in a safe pla ce for futur e r efer ence.
2 Ener co | Compa ct Unit Heater Opera ting Instructions and Owner’s Manu al GENERAL HAZARD W ARNING: F AIL URE T O COMPL Y WITH THE PRECA UTIONS AND INSTR UCTIONS PR O VIDED WITH THIS HEA TER, CAN .
3 Oper ating Instructions and Owner’s Manu al Ener co | Compa ct Unit Hea ter MHU4 5/MHU7 5 AND HSU4 5/HSU7 5 UNIT DIMENSIONS (N-NA TURAL GAS, P-PR OP ANE) GAS INLET SIDE VIEW SER VICE A CCESS P ANE.
4 Ener co | Compa ct Unit Heater Opera ting Instructions and Owner’s Manu al SHIPPING The heater is completely assembled. Installation instructions, two mounting br a cke ts (shipped loose), and a flu e tr ansition are included. Check the unit for shipping d amage.
5 Ope r atin g Inst ruc tion s and Owner ’s Man ual Ene r co | Comp a ct Unit Heater These units are approved for residential applications. For installation in a residential g arage, the se unit s must b e insta lled so th a t b urner s and ignition so urce are located n o l ess than 1 8 ” (4 5 7mm) a bov e fl oor .
6 Ener co | Compa ct Unit Hea ter Opera ting Instructions and Owner’s Manu al B – V E RTI C AL VE NT S U S IN G ME T AL VE N T P IP E – CO MM E RC IA L AN D RE S ID EN T IA L IN ST AL L A TIO NS MHU/HSU compact unit heaters are listed as Category I appliances for vertical vent installations.
7 Ope r atin g Inst ruc tion s and Owner ’s Man ual Ene r co | Comp a ct Unit Heater 5 . V en t te rmination must be a min imum of 4' (1 .2m ) below or 4’ (1 .2m) horizontally fr om an y sof fit v ent or unde r-eave ven t. 6 . V en t must be a minimum of 6' fr om an insid e corn er forme d by t wo e xter ior walls.
8 Ener co | Compa ct Unit Hea ter Opera ting Instructions and Owner’s Manu al F – VE N TI NG USI N G A MA S ON R Y CHI M NE Y The following additional requirements apply when a lined masonry chimn ey is bei ng use d to v ent the compact uni t heater .
9 Oper ating Instructions and Owner’s Manu al Ener co | Compa ct Unit Hea ter 5 . T est for spillage a t the dr aft hood relief opening after fiv e minutes of main burner operation. Use the flame of a ma tchor candle, or smok e fr om a cigare tte, cigar , or pipe.
10 Ener co | Compa ct Unit Hea ter Opera ting Instructions and Owner’s Manu al control board emits radio noise as the sparking process is unde rway . T he lev el of energy ma y be suf fici ent to distur b a logic circuit in a microprocessor controlled thermostat.
11 Ope r atin g Inst ruc tion s and Ow ner ’s Man ual Ene r co | Comp a ct Unit Heater 1 3 . If appliance still will not opera te, follow the ins tructions “T O TURN OFF G AS TO UN IT” and call y our ser vice t echnici an or gas supplier . TO T UR N O FF GA S TO U NI T 1 .
12 Ener co | Compa ct Unit Hea ter Opera ting Instructions and Owner’s Manu al mini mum of 5.0 " w .c. for natur al gas or 1 0 .4" w .c. f or LP/ propane gas should be maintained for proper unit operation. 2 . After line pressure has been checked and adjusted, check manifold pressure.
13 Ope r atin g Inst ruc tion s and Ow ner ’s Man ual Ene r co | Comp a ct Unit Heater WI R IN G S C HE MA TI C FO R UN IT S W IT H 6- P IN CO N NE C T O R SC N- K WC CO N TR OL BO AR D N O T E :I F.
14 Ener co | Compa ct Unit Hea ter Opera ting Instructions and Owner’s Manu al P ART S L I S T: SEE BACK P AGE FOR P AR TS ORDE RING INFO RMA TION CO M BU ST I ON AI R BL O W E R Under normal operating conditions, the combustion air blower should be checked and cleaned prior to the heating season with the power supply disconn ected.
15 Oper ating Instructions and Owner’s Manu al Ener co | Compa ct Unit Hea ter Mr . Heater / Hea tStar • Compact Unit Heater • Model # MHU4 5 /7 5 HSU4 5/7 5.
16 Ener co | Compa ct Unit Hea ter Opera ting Instructions and Owner’s Manu al W A R N I N G : USE ONL Y MANUF A CTURER’S REPLA CEME NT P A R TS. USE OF ANY O THER P A R TS COULD CA USE INJUR Y OR DEA TH. REPLA CEME NT P A R TS ARE ONL Y A V AIL ABL E DIRECT FR OM THE F A CT OR Y AND MUS T BE INST ALLE D B Y A Q U ALIFIE D SER VICE A GENCY .
Een belangrijk punt na aankoop van elk apparaat Enerco MHU 75 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enerco MHU 75 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enerco MHU 75 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enerco MHU 75 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enerco MHU 75 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enerco MHU 75 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enerco MHU 75 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enerco MHU 75 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.