K eep This Manual With Air Conditioner AIR CONDITIONER OPERA T OR'S MANU AL CA UTION BEFORE INST ALLING AND USING THIS AIR CONDITIONER, IT IS IMPORT ANT THA T THIS MANU AL BE READ AND UNDERST OOD THOR OUGHL Y K OOL TRONIC, INC. 30 P ennington-Hopewell Road P ennington, NJ 08534 609 • 466-3400 F AX: 609 • 466-1114 www .
T ABLE OF CONTENTS P age I. Introduction 2 II. Incoming Inspection 3 III. Product Handling 3 IV . Product Identification Label 4 V . Pr inciples of Operation 5 - 6 VI. Pre-Installation T esting 6 VII. Specific Model Data 7 - 10 Mounting Dra wings and Dimensions T echnical Data Major Component Replacements Standard F eatures Wiring Schematic VIII.
3 II. Incoming Inspection K ooltronic Air Conditioners are designed, b uilt and packaged to withstand the shoc k and vibration normally associated with shipment by common carriers.
4 IV . Pr oduct Identification and Labels Each K ooltronic Air Conditioner includes an identification label. This label provides: ➀ Model Number ➁ Serial Number ➂ Electrical power characteristic.
V . Principles of Operation K ooltronic Air Conditioners are required when the equipment operating temper ature must be k ept near or low er than the ambient room temperature, and/or the cabinet m ust be sealed from dust, fumes, oil, corrosiv es and other contaminants.
The heater kit consists of a heater , a heat control ther mostat and a heater limiter . The heater control ther mostat is a bimetal disk with a fix ed set point of 60°F . When the entering e vapor ator air temperature r ises abov e 60°F the heater shuts off, and when the e vapor ator air temperature f alls below 40°F the heater will engage.
VII. Specific Model Data Mounting The K ooltronic Special Pur pose Air Conditioners K_NA4C3P21R hav e been engineered to be installed easily . These units utilize doub le lay er gaskets. The first gasket la yer is placed on the outside perimeter of the front panel that is sealed against the customer enclosure.
8 21.19 [538.2] DRAIN 12.48 [316.9] .36 [9.1] 8.08 [205.2] TYP. 3.40 [86.3] TYP. 9.20 [233.6] TYP. 11.54 [293.1] TYP. 9.20 [233.6] 7.50 [190.5] 1.92 [48.7] 2.00 [50.8] 12.01 [305.0] POWER CORD Drawings and Dimensions K_NA4C3P21R SERIES Dimensions, inches [mm], are f or reference only and are subject to change.
9 T echnical Data KNA4C3P21R 3000 2160 125 0 115 60 11.3 76 K2NA4C3P21R 3000 2160 131 0 230 60 4.7 76 K2NA4C3P21R5 3000 1940 131 0 230 50 4.6 76 * Rating shown is f or operation at maximum ambient temperature . Ambient Ambient Appro ximate BTU/H BTU/H T emp.
10 Wiring Schematic EVAPORATOR FAN CAP. WE GN SUPPRESSOR HEATER THERMAL CUTOUT T-STAT 115 V 230 V TO CUSTOMER ALARM SYSTEM (OPTIONAL) TERMINAL BLOCK COOLING EFFECT DETECTOR BK T-STAT SHORT CYCLE TIMER OPTIONAL SHORT CYCLE PROTECTOR OPTIONAL HEATER SPEED CONTROLLER CONDENSER BLOWER MOTOR CAP.
11 VIII. Maintenance K ooltronic W ater-Cooled Air Conditioners require no maintenance. Air-Cooled Air Conditioners are designed to require only the routine cleaning of air filters to assure unimpeded airflo w through the condenser heat e xchanger .
12 B. Blower s The design lif e of the blowers used in all K ooltronic Air Conditioners is substantially in excess of 20,000 hours. All Kooltronic condenser and e vapor ator blow ers are equipped with automatic-reset ther mal o verload protectors.
. IX. T roub le-Shooting Each K ooltronic Air Conditioner is engineered for perf or mance and b uilt f or reliability . They are designed to require no routine maintenance other than the cleaning of ambient air filters. If your air conditioner should require warr anty ser vice, please contact K ooltronic.
14 This page intentionally left blank.
15 THIS W ARRANTY CONSTITUTES THE ENTIRE W ARRANTY WITH RESPECT T O THE PR ODUCT AND IS IN LIEU OF ALL O THERS, EXPRESSED OR IMPLIED , INCLUDING ANY W ARRANTY OF MERCHANT ABILITY AND W ARRANTY OF FITNESS FOR A P ARTICULAR PURPOSE AND IN NO EVENT IS K OOL TRONIC RESPONSIBLE FOR ANY CONSEQUENTIAL D AMA GES OF ANY NA TURE WHA TSOEVER.
BEAT THE HEAT! KoolTray II - 19” width fan cooling units. Available in 1, 2 and 3 row configurations. Custom/Special units available. Pennington, NJ Ventura, CA Tel: (609) 466-3400 Tel: (805) 642-85.
Een belangrijk punt na aankoop van elk apparaat Event electronic K_NA4C3P21R (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Event electronic K_NA4C3P21R heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Event electronic K_NA4C3P21R vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Event electronic K_NA4C3P21R leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Event electronic K_NA4C3P21R krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Event electronic K_NA4C3P21R bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Event electronic K_NA4C3P21R kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Event electronic K_NA4C3P21R . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.