Gebruiksaanwijzing /service van het product 500VA UPS Duo II Pro van de fabrikant Ever
Ga naar pagina of 16
.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 2 T A BLE OF CONTENTS TABLE OF CON TENT S .. .......... ........... .......... ........... ........... .......... ........... .......... ........... .......... ........... .
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 3 INTRODUCTI ON Thank you for purcha sing the DUO II / DUO II Pro UPS . Plea se familiarise yourself with this instru ction manual before you b egin u sing the device. W e hope that the purchased UPS will meet your e xpectations.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 4 ELEMENTS OF THE UPS FRONT PANEL 1. Power switch 2. Operation mode indicator 3. Malfunction indicator REAR PANEL 1. 4 x IEC 320 outlet sockets 2. 10 A circuit breaker 3. Power lead 4.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 5 S A FETY A ND HE AL TH INSTR UCTIONS HANDLING • exercise utmost caution when h andling the device; • do not handle heavy equipment b y y ourself ; • storage and o peration of the device should ta ke p lace in conditions confo rming to its specification.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 6 WARNING! DUO II / DUO II P ro UPSs we re not designed to w ork w ith medical equipment, in particular life and/or health s upport devices. WARNING! Opening the casi ng may result in e lectric shock.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 7 CONNECTING THE UPS Due to th e type and placement of cut-outs present in the UPS the safety circuits of the bu ilding function as one of the prote ction measures. This is e ssential to provide the UPS w ith shorting protec tion.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 8 depends on the capacity of the internal batterry a nd the power of de vices currently connected to the output (load ).
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 9 SAFEGUARDS A ga inst overloads T h e ov e r l o a d pr o t e ct i o n c i r c ui t i n d i c at es a n o v er l oa d i .
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 10 COMMUNIC A TION BETW EEN THE UPS AND A COMPUTER DUO II Pro ba ttery ba ck-ups are equipped with a USB port enabling communication of the UPS with a com puter. The d evice is supplied with a CD-ROM f eaturing the PowerSoft p rogramme and a USB co mmunication cable.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 11 of the PowerSoft software (usually C:Program FilesPowerSoft ) to be searched.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 12 dpkg –-remove powersoft FreeBSD For FreeB SD systems t he sof tware is p rovided in the form of the default package format de signed for Free BSD systems. Th e so ftware is insta lled via the following command: pkg_add powersoftpersonal-x.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 13 ADDITION A L REM A RKS WARNING! Inside the UPS there are no eleme nts to be serviced by the end user. CUT-OUT The UPS is equipped with a resettable circuit breaker. W hile in n ormal operation mode of the UPS the brea ker’s b utton should b e p ressed in.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 14 WARNING! Do not connect LAN cable s w ith RJ45 terminators because it may interrupt the transm ission.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 15 TECHNIC A L P ARAMETERS PARAMETERS Duo II 350 Duo II Pro 350 Duo II 500 Duo II Pro 500 Duo II 800 Duo II Pro 800 Duo I.
DUO II / DUO II Pro series UPS – I nstruction Ma nual 2010/03/19 www.ever.eu 16 INFORM A T ION REG ARDING REGUL A T IONS, W A RR A NTY AND SUPP ORT DECLARATION OF CONFORMITY Manufactured in People's Rep ublic of China. The UPSs stru cture co nforms to the appropriate subject matter standa rds.
Een belangrijk punt na aankoop van elk apparaat Ever 500VA UPS Duo II Pro (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Ever 500VA UPS Duo II Pro heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Ever 500VA UPS Duo II Pro vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Ever 500VA UPS Duo II Pro leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Ever 500VA UPS Duo II Pro krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Ever 500VA UPS Duo II Pro bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Ever 500VA UPS Duo II Pro kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Ever 500VA UPS Duo II Pro . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.