S peed Dome EPTZ900/500 USER MANUAL Date: June 2006.
1-1 T able of Content s 1. EPTZ900/500 OVERVIEW ................................................ 1-3 1.1. Introducti on .............................................................................................1-3 1.2. Specificati ons .
1-2 2.4.1. Inst allation Requireme nt s .............................................................. 2-20 2.4.2. EPTZ900 Dome Camera W all Mount Inst allation ......................... 2-20 2.4.3. EPTZ500 Dome Camera Inst allation .
1-3 1. EPTZ900/500 OVERVIEW 1.1. Introduction EPTZ900/500, an intelligent high-speed dome camera is ready to secure your property with its omni-directional and exact m onitoring. An 18X optical and 12X digital zoom combining with a hi gh-performance chip makes captured images clear and vivid.
1-4 All of the features make the intelligent high-speed dome camera works for a wide range and demanding application such as banks, airport s, stations, casinos, street s of cities, intelligent buildings, and etc.
1-5 1.2. Specifications Model EPTZ900 EPTZ500 Pickup Device 1/4" type Sony Super HAD CCD Video Format NTSC or PAL Scanning System NTSC: 525 TV lines, 60 fields/sec PAL: 625 TV lines, 50 fields/sec Picture Elements 768 x 494 ( NTSC ) , 752 x 582 ( PAL ) Horizontal Resolution 480 TVL Sensitivity 1.
1-6 Running To Position Speed 1 - 239 grade available,0.1º/s - 360º/s Dwell Time At Preset Position 1 - 239 second available Tour 16 group Tour Point Per Group 16 preset positions Fan, Heater (EPTZ900) Fan & Heater auto starts No Position Accuracy ±0.
1-7 1.3. Feature 1.3.1. Profile of EPTZ900/500 EPTZ900 Wall Mount Bracket Housing Inner Hous ing M5 Bolt (Hex) x3 M3 Bolt x3 BNC Cable Power Cable RS485 Cable Connection Bu s Bulb Mechanic al Part Cam.
1-8 1.3.2. Base Board The base board that is on the bottom of the housing connects to power cable, video cable, control cable, alarm cable, fan and heater (fan and heater are for EPTZ900 only). In order to connect to cables, the board needs to be taken of f, and put back after finishing connecting to all cables.
1-9 RELAY JP5 Video + Video - RS485 + RS485 - AC24 AC24 EPTZ500 Baseboard 1.3.3. EPTZ900/500 Control Board The PCB board with two dipswitches is the control board of speed dome. The two switches are used to set address, protocol, Baud Rate, video format and terminator resistance.
1-10 1.4. EPTZ900/500 Connection Alarm 1 Alarm 4 Alarm 3 Alarm 2 GROUND RS485 Tx(+) RS485 Tx(-) 24V AC 110V AC Video Out POWER 24V AC / 3.5 A BNC 1.0Vpp ± 0.
1-1 1 1.5. EPTZ900/500 Quick Operati on Guide (Wo rk with EKB500) EPTZ900/500 and EKB500 (Keyboard) can work together by using factory default setting. Y ou just need to connect cables by following the steps: 1. Connect the RS485 cable to EP TZ900/500 and a Keyb oard (EKB500).
2-12 2. EPTZ900/500 INSTALLATION 2.1. Packing List There are 3 boxes that are housing, bulb and mechanical part with a camera module, one wall mount bracket, one power adapter and one accessory packet in the p ackage.
2-13 z V ideo Cable A BNC cable is used for connecting a speed dome to a DVR or a monitor . An amplifier may be needed if the video cable is too long. z Control Cable Basically , EPTZ900/500 uses a differential pair to connect to other devices by cascading.
2-14 2.3.1. Address Setting The address code of the EPTZ900/500 shou ld be set to correspond properly with a control device to control multiple dome ca meras.
2-15 ON 12345678 Swit ch Address 1 ON 12345678 2 ON 12345678 3 ON 12345678 4 ON 12345678 5 ON 12345678 6 ON 12345678 7 ON 12345678 8 ON 12345678 9 ON 12345678 10 ON 12345678 11 ON 12345678 12 ON 12345.
2-16 ON 12345678 Switch Address 129 ON 12345678 130 ON 12345678 131 ON 12345678 132 ON 12345678 133 ON 12345678 134 ON 12345678 135 ON 12345678 136 ON 12345678 137 ON 12345678 138 ON 12345678 139 ON 1.
2-17 2.3.2. Communication Protocol Setting The 1 st , 2 nd and 3 rd bits of the SW2 are used to set communication protocol. The factory default protocol is EVF .
2-18 2.3.4. Video Format Setting The 6 th bits of the SW2 on the PCB board ar e used to set the video format. The default video format depends on the factor y setting.
2-19 CAM-0 CAM-1 CAM-n Keyb oard DVR RS485 Control Unit n ≦ 255 Ter ni mato r Resistance ON Note: When the dome is out of control, or does not work under control well, try to switch the terminator resistan ce ON. Notice: Please make sure the power is off befo re setting, and restart the speed dome to enable a new value after changing.
2-20 2.4. Rack and Speed Dome Inst allation 2.4.1. Inst allation Requirement s 1. Installation should be handled by a qualifi ed service agent and should comply with all local regulations.
2-21 2. Thread the cable through the hole in the wall mount bracket, and screw in 4 M8 nuts for mounting the bracket. 3. T ake off the housing from the pa cking, and take of f the baseboard (4 bolts on it.) inside the housing. Thread the cable th rough the top of the housing.
2-22 5. Align the two screw holes on the bottom of mechanical part to the two bolts on the base of the housing, and twist the mechanical part clockwise a little bit in order to engage it with the base. Screw the two bolts on the base, and then connect and fix the connection bus to the PCB board on the mechanical part.
2-23 Notice: In order to protect the bulb from dirt and scrape, please put on the gloves before installing the bulb. 7. T urn on the power , and st art to operate the EPTZ90 0 . Note: When turning on the power , the EPTZ900 wi ll enter self-inspection mode, and carry out a self-testing program.
2-24 2.4.3. EPTZ500 Dome Camera Installation 1. T ake off the housing from the pa cking, and take of f he PCB board (4 bolts on it) inside the housing. 2. Cut the ceiling against t he housing’ s shape with a saw . 3. Thread the cable through t he screw and the hole on the top of the housing, and tighten up the screw to fix the cable 4.
2-25 Notice: Please notice the polarity of control line. The EPTZ500 will not work if the polarity of control line is mis-connected. 6. Align the two screw holes on the bottom of mechanical part to the two bolts on the base of the housing, and twist the mechanical part clockwise a little bit in order to engage it with the base.
2-26 GLOVE Connection wire Button Button Notice: In order to protect the bulb from dirt and scrape, please put on the gloves before installing the bulb.
2-27 2.5. Sep aratel y Sold Accessories 2.5.1. Pole mount The pole mount is used for installing a speed dome on the ceiling indoors or outdoors. The extension poles are av ailable for the pole mount. 2.5.2. Pole adapter The pole adapter is used for installing a wall mount bracket to a pole indoors or outdoors.
3-28 3. EPTZ900/500 CAMERA SETUP MENU In this section, setup and operation guide of EPTZ900/500 will be introduced. There are 22 items of the se tting menu. However , there is only one line on the line display , so using some combinat ion keys to operate is necessary .
3-29 3.1.1. Camera Setup Menu Press MENU to enter camera setup menu. Press Shift + Joystick up/down to change subentri es, and right/left to change the setting. 1. CAM ID : The name assigned to the camera. 2. DZOOM : Digital zoom enable or disable.
3-30 6. DISPLA Y : Display system information and st atus. ON: T o display the system inform ation and status on the screen. OFF: Not to display the system info rmation and st atus on the screen. 7. BACKLIGHT : Backlight compensation. ON: Enable backlight compensation.
3-31 12. ALM-IN2 SET : The status of input alarm 2. N.O.: Enable a normal open alarm input. N.C.: Enable a normal close alarm input. OFF: Disable alarm input. 13. ALM-IN3 SET : The status of input alarm 3. N.O.: Enable a normal open alarm input. N.
3-32 17. LOAD DEF AUL T : Load default setting. Select this item, and then press “ Enter ” to load default setting. Press “ Clr ” + “ Menu ” whenever yo u want to quit menu setting. 18. EXIT : To e x i t . Select this item, and then pr ess “ Enter ” to quit setting.
4-33 4. EPTZ900/500 FUNCTION SETUP AND OPERATION 4.1. Manual Control Mode ¾ Manual control: Shift Joystick Up/Down/Lef t/Right, and turn it Clockwise/Counterclockwise to control speed dome. Use the control keys which are Zoom , Focus and IRIS function keys on the keyboard to zoom In/Out, focus N (near)/F (Far), or IRIS +/-.
4-34 ¾ Preset a position: Shift the Joystick to the p ositi on you would like to preset, and then press Shift + Position . The system will ask you to enter t he preset position number (1~239), and then press Enter to sa ve the position. There are up to 192 positions can be preset.
4-35 ask you to enter the tour number you would like to run, and start s the tour after pressing Enter. T o preset a tour before running it is necessary . Note: The dif ference between the One-way tour mode and T o-and-fro t our mode is their return modes.
4-36 RELAY JP 6 JP4 JP 3 JP 1 JP 5 Video + Video - RS485 + RS485 - AC24 AC24 JP 5 1 ~ 9 APPENDIX A: The Alarm I/O Connection There are 4 alarm inputs and 1 alarm output ava ilable. The alarm I/O connector that is marked as JP5 is a nine-pin connector .
4-37 APPENDIX B: Protocol =============== ============= =============== ====== Speed Dome Cont rol Protocol =============== ============= =============== ====== 1-1. Format A. Fixed 7 bytes packet Byte1 (cmd1 = 0xFA) Byte2 (cmd2) Byte3 (ID high byte ) Byte4 (ID low byte) Byte5 (data1) Byte6 (Keyboard-ID) Byte7 (checksum) B.
4-38 2-1. Part-I =========== ============= =============== ============ =============== ============ =============== ============ ===== | (B1) ( B2) (B3) (B4) (B5) ( B6) (B7) | FUNCTION | CMD1 C MD2 I.
4-39 ----------- ------------- ------+ ----- - ----- ----- ----- ------- - ---- -----+- --------------- ------------ ----- Set Single Point Alarm L inkage| FA 7A-7D . . pp . cs | pp=1-192 (posit ion) Clr Single Point Alarm L inkage| FA 7E-81 . . AA . cs | Cruise Alar m Linkage Set | FA 82-85 .
4-40 ----------- ------------- ------+------ - ---- ----- ----- ------ - ---- ----- -----+-------- ------------ ------- set preset position titl e | FC 0 5 . . x-coor . char cs | x-coor= 0-19 | | char=AS CII code | | notice: | | make s ure you alre ady send | | "FA A0 " command, b efoe send | | this c ommand.
4-41 EverFocus Electronics Corp. Head Office: 12F , No.79 Sec. 1 Shin-T ai W u Ro ad, Hsi-Ch ih, T aipei, T aiwan TEL: +886-2-26982334 F AX: +886-2-26982380 www .everfocus.com.tw USA Office: 1801 Highland Ave. Unit A Duarte, CA 91010, U.S.A. TEL: +1-626-844-8888 F AX: +1-626-844-8838 www .
Een belangrijk punt na aankoop van elk apparaat EverFocus EPTZ900 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen EverFocus EPTZ900 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens EverFocus EPTZ900 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding EverFocus EPTZ900 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over EverFocus EPTZ900 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van EverFocus EPTZ900 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de EverFocus EPTZ900 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met EverFocus EPTZ900 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.