Gebruiksaanwijzing /service van het product DEC200 van de fabrikant Exide
Ga naar pagina of 20
DEC200 SERIES INDUSTRIAL BATTERY CHARGER I&O MANUAL.
Sales • Service • Recycling 1-888-563-6300 1 TABLE OF CONTENTS TITLE Page 1. Important Operating Instructions 2 2. Introduction 3 3. Receiving Instructions 3 4. Location and Installation of Charger 3 5. Stacking 3-4 6. AC Electrical Supply 5-8 6.1 Branch Circuit Protection 5 6.
Sales • Service • Recycling 1-888-563-6300 2 DEC200 SERIES INDUSTRIAL BATTERY CHARGERS 1. IMPORTANT OPERATING AND SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS a) Before usin g the battery charger, read all the instructions in add ition to the CAUTION, WARNING, and DANGER markings on the charger, battery, and all the associated equipment.
Sales • Service • Recycling 1-888-563-6300 3 2. INTRODUCTION The GNB ® DEC200 battery chargers are fan cooled, solid state, microprocesso r controlled, SCR regulated chargers designed to make battery charging simple. They are designed to charge flooded lead-acid batteries.
Sales • Service • Recycling 1-888-563-6300 4 b) Remove the bolts from the top cover of the base unit, but do not discard these, as they will be required to fix the two units together.
Sales • Service • Recycling 1-888-563-6300 5 6. AC ELECTRICAL SUPPLY The charger must be connected to either a single phase o r three phase, 60 Hertz ( ± 2%) AC power source.
FIGURE 1: SINGLE PHASE INPUT WARNING: IMPROPE R WIRE AND JUMPER C ONNECTION MAY CAUSE SEVERE DAMAGE TO THE CHARGER AND BATTER Y NOTE : Live connection ‘L’ Must be connected to the br eaker. The mains input are the only user configurable connections.
FIGURE 2: THREE-PHASE INPUT WARNING: IMPR OPER WIRE AND JUMP ER CONNECTION MAY CA USE SEVERE DAMAGE TO THE CHARGER AND BATTER Y NOTE : PCB connections must NOT be altered from factory setting.
Sales • Service • Recycling 1-888-563-6300 8 6.2. AC VOLTAGE CONNECTIONS To connect the input AC voltage, route the AC conduit through the knockout hole provided. Continue the AC wiring to the breaker terminals L1 (N) and L2 (L) (single phase input) or L1, L2, and L3 (three phase input).
Sales • Service • Recycling 1-888-563-6300 9 9. DEC200 ST ANDARD CHARGER OPERATION CHARGE CONDITION DISPLAY DEFAULT FUNCTION BUTTON DISPLAY SELECTI ON LED CHARGING A A, Ph Y TERMINATION rEdy G TER.
Sales • Service • Recycling 1-888-563-6300 10 10. CHARGER FUNCTI ONAL DESCRIPTION 10.1. LED Descriptions LED Description Yellow Flashing High Rate Current Yellow Solid 80% Charged Green Solid Charge Complete Red Fault – See page 15 for codes 10.
Sales • Service • Recycling 1-888-563-6300 11 10.6 EQUALIZE PUSHBUTTON Equalize charge can be enabled/disabled, when the FUNCTION button is depressed > 5 second at anytime whilst a battery is connected. Only one equalize charge per recharge cycle is permitted.
Sales • Service • Recycling 1-888-563-6300 12 11 MAINTENANCE The charger requires minimum maintenanc e. ENSURE THE CHASSIS IS SECURELY GROUNDED per the local/federal Electrical Code. Do not allow excessive dust to accumulate on the components inside.
Sales • Service • Recycling 1-888-563-6300 13 APPENDIX A – FAULT CODES CODE STATUS DESCRIPTION F01 N Over discharged battery (<1.90vpc after 30 seco nds of charge) F02 N Deep discharged battery (<1.90vpc a fter 30 second s of charge > 1 .
Sales • Service • Recycling 1-888-563-6300 14 APPENDIX B – DEC200 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE EXPLANATI ON / ACTION No Display No AC Power Check Input Power. Check Brea ke r. Mains fuse on Control Board F01 Deeply Discharged Battery Battery Voltage less than 1.
APPENDIX C –TECHNICAL DATA *DC FUSE MUST B E A FAST ACTI NG FUSE CAPABL E OF PROTECTIN G SEMICONDUCTO RS. Sales • Service • Recycling 1-888-563-6300 15 Amp-Hour Rating AC AMPS ( RMS) @ AC VOLTS @ 2.
APPENDIX D bl '0' CON1 FS1 1 2 3 4 bl gy bl br PCB1 br bk rd bl wh wh '0' wh '1' bl '1' wh '2' bl '2' Shunt bl gy + _ bl FS2 16 wh '2&a.
APPENDIX D OR bl gy bl br PCB1 bk rd bl wh wh wh Shunt bl gy + _ bl FS2 wh rd wh bl rd rd bk Component No: CLT6005 DRAWING TIT LE: GNB [UL] Single phase wiring diagram Fuse / Breakers CON 5 1 2 3 4 5 .
APPENDIX E – DIMENSIONS CABINET DIM. A DIM. B DIM. C DIM. D DIM. E Size M4 19.69” 26.65” 16.93” 17.54” 12.99” Size M5 23.62” 26.65” 20.
SALES – SERVICE - RECYCLING 1-888-563-6300 TOLL FREE GNB Industrial Power A division of Exide Technol ogies U.S.A. Tel: 877.462.4636 GNB Industrial Power A division of Exide Technol ogies Canada Tel: 800.
Een belangrijk punt na aankoop van elk apparaat Exide DEC200 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Exide DEC200 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Exide DEC200 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Exide DEC200 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Exide DEC200 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Exide DEC200 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Exide DEC200 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Exide DEC200 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.