ISM 824 Integration Scaling Multiswitcher 68-1123-01 Rev . A 02 08.
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
ISM 824 Integration Scaling Multiswitcher ii.
Qu ic k St ar t — ISM 824 Integration Scaling Multiswitcher H /H V RGBHV Video RGsB or Component Video S-Video Composite Video RGBS Video V H/ HV V H/HV V H/HV V H/HV V R/R- Y G/ Y VI D B/ C B-Y R /.
AC T LIN K LAN Figure Q-5 — Initial startup sequence Fr ont Panel Operations Making input to output ties T o make input ties to untied outputs: 1 . Press the Esc button (clears any changes that may be pending). 2 . If not already lit, select the video button (lights green ), audio button (lights red ), or both.
Picture adjustments The ISM 824 has six buttons for picture adjustment modes (color/tint, brightness/ contrast, detail, position, size, and zoom). PICTURE ADJUSTMENTS POSITION DET AI L SIZE ZOOM BRIGHT / CONT COLOR/ TINT T o make pictur e adjustments do the following: 1 .
ISM 824 Menu System The ISM 824 has a six level menu system. Access to each level and sub level is made by using the menu control buttons. • Menu button — The Menu button enters and moves through the main menu system in the ISM. • Next button — The Next button steps through the submenus in the ISM menu system or exits the menu system.
TOC - i ISM 824 Integration Scaling Multiswitcher • T able of Contents T able of Contents Chapter On e • Introduction ...................................................................................................... 1-1 About this Manual ....
TOC - ii ISM 824 Integration Scaling Multiswitcher • T able of Contents T able of Contents, cont’d Front Panel Operation ............................................................................................................. 3-6 Making input to output ties .
TOC - iii ISM 824 Integration Scaling Multiswitcher • T able of Contents Advanced Config ........................................................................................................ 3-39 View Comm Settings menu .........................
TOC - iv ISM 824 Integration Scaling Multiswitcher • T able of Contents T able of Contents, cont’d Help .............................................................................................................................. 5-12 I/O Control page .
TOC - v ISM 824 Integration Scaling Multiswitcher • T able of Contents Chapter 6 • HTML Operation ..................................................................................................... 6-1 Downloading the Startup Page ..............
TOC - vi ISM 824 Integration Scaling Multiswitcher • T able of Contents T able of Contents, cont’d Help ............................................................................................................................... A-5 Quit ......
1 Chapter One Intr oduction About this Manual About the Integration Scaling Multiswitcher Definitions Features ISM 824 Integration Scaling Multiswitcher.
ISM 824 Integration Scaling Multiswitcher • Introduction 1-2 Intr oduction About this Manual This manual contains installation, configuration, and operating information for the Extron ISM 824 Integration Scaling Multiswitcher with optional output boar ds.
1-3 ISM 824 Integration Scaling Multiswitcher • Introduction The multiswitcher accepts up to eight video inputs of various resolutions on five female BNC connectors per input. Depending on the output card congurations, the multiswitcher scales, down-converts, or simply passes the video inputs to output RGB or YUV video.
Intr oduction, cont’d ISM 824 Integration Scaling Multiswitcher • Introduction 1-4 Balanced or unbalanced stereo or mono audio inputs ar e made on eight 5-pole captive screw connectors, number ed 1 through 8.
1-5 ISM 824 Integration Scaling Multiswitcher • Introduction Featur es Inputs — V ideo inputs — The ISM switches among eight congurable RGB, HDTV component video, component video, S-video, and composite video inputs.
Intr oduction, cont’d ISM 824 Integration Scaling Multiswitcher • Introduction 1-6 Audio gain/attenuation — Users can set the input level of audio gain or attenuation (-18 dB to +24 dB) via the RS-232/RS-422 or Ethernet link, or from the front panel.
1-7 ISM 824 Integration Scaling Multiswitcher • Introduction Video Scaler car d (ISM VS) Auto Image ™ — Only for scaled outputs The auto imaging feature automatically sizes and centers the selected input to fill the screen. Auto imaging can be selected for individual outputs as desired.
Intr oduction, cont’d ISM 824 Integration Scaling Multiswitcher • Introduction 1-8.
ISM 824 Integration Scaling Multiswitcher 2 Chapter T wo Installation U/L Safety Requirements Mounting the Switcher Rear Panel Features and Connection.
Installation, cont’d ISM 824 Integration Scaling Multiswitcher • Installation 2-2 Installation UL/Safety Requir ements The Underwriters Laboratories (UL) requir ements listed below pertain to the safe installation and operation of this Integration Scaling Multiswitcher .
2-3 ISM 824 Integration Scaling Multiswitcher • Installation Mounting the Switcher If the ISM 824 is to be rack mounted, it is important to mount it before cabling it. Four uninstalled rubber feet are included with the ISM 824. Install the feet only if the unit is to be mounted on a table top (see “T abletop placement” below).
Installation, cont’d ISM 824 Integration Scaling Multiswitcher • Installation 2-4 Rear Panel Featur es and Connection Figure 2-2 — ISM 824 r ear panel features Power and control connections a AC.
2-5 ISM 824 Integration Scaling Multiswitcher • Installation Cabling and RJ-45 connector wiring It is vital that the Ethernet cables used be the correct type of cable, and that they be properly terminated with the corr ect pinout.
Installation, cont’d ISM 824 Integration Scaling Multiswitcher • Installation 2-6 Input connections There ar e video and audio connectors for eight inputs. e V ideo input connectors — Connect computer or RGB video, component video, S-video, or composite video to any of the eight sets of 5 female BNC connectors.
2-7 ISM 824 Integration Scaling Multiswitcher • Installation Output connections The basic device has video and audio connectors for two pass-through outputs. W ith four optional cards installed, there ar e video and audio connectors for up to eight outputs.
Installation, cont’d ISM 824 Integration Scaling Multiswitcher • Installation 2-8 Optional output card connections Video output connections i Ther e are dif ferent output car d options available, for the four expansion slots at the rear of the ISM 824.
2-9 ISM 824 Integration Scaling Multiswitcher • Installation Installing the optional output cards If the optional cards ar e already installed in the ISM 824, connect suitable display devices and configure the input and outputs as applicable. See chapter 3, “Operation and Setup”, for front panel operation.
Installation, cont’d ISM 824 Integration Scaling Multiswitcher • Installation 2-10 N If the device does not recognize a newly installed card, power the unit down, remove the card and r e-install, closely following steps 4 through 7 above. If it continues to not recognize the card, contact Extr on HelpLine (see rear cover).
ISM 824 Integration Scaling Multiswitcher 3 Chapter Thr ee Operation and Setup Front Panel Features Powering Up Front Panel Operation ISM 824 Menu System Resetting the Unit with the Reset Button.
ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-2 Operation and Setup Operation and Setup Fr ont Panel Features All of the ISM 824’s controls and indicators ar e on the front panel (figure 3-1).
3-3 ISM 824 Integration Scaling Multiswitcher • Operation and Setup Control buttons c Control selection buttons — These four buttons give direct access to enter (save), pr esets, views, and esc (exit) controls.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-4 Picture adjustment contr ols e Picture adjustment control buttons — These six buttons give direct access to color/tint, brightness/contrast, detail, position, size, and zoom adjustment control.
3-5 ISM 824 Integration Scaling Multiswitcher • Operation and Setup 6 fe et 5 1 9 6 Slee ve (Gnd) Ring Tip 9-pin D Connection TRS Plug Pin 2 Computer's RX line Tip Pin 3 Computer's TX line Ring Pin 5 Computer's signal ground Slee ve Figure 3-2 — Fr ont 2.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-6 Fr ont Panel Operation T o enable any selected input signal to be viewed on a display device, the input must be tied to an output. Any input can be tied to any output.
3-7 ISM 824 Integration Scaling Multiswitcher • Operation and Setup The following example illustrates the principles of making new video/audio ties. An example of creating a set of video and audio ties In the following example, input 3 is tied to outputs 2, 6, and 7 as video and audio.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-8 Viewing ties T o view existing ties do the following; 1 . Press the V iew button (lights red ) . 2 . The input/output ties can be viewed on the LCD display .
3-9 ISM 824 Integration Scaling Multiswitcher • Operation and Setup Adding ties to existing ties An audio tie can be added to an existing video tie, likewise a video tie can be added to an existing audio tie. An example of adding an audio tie to an existing set of video ties In the following example audio is added to existing video ties.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-10 5 . Press and r elease outputs 3 and 4 buttons (figure 3-9). The output buttons flash red . 6 . Press and r elease the Enter button (gure 3-9). Input and output buttons extinguish.
3-11 ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3 . If lit, deselect (press) the Audio button (lit red ). This button extinguishes, leaving only video (lit green ) for this selection (see figure 3-12). 4 . Press and r elease the Input 3 button (see figure 3-13).
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-12 Replacing ties Existing output ties from any can input be r eplaced with another input, as long as that input is of a similar type (e.g., video for video and audio for audio).
3-13 ISM 824 Integration Scaling Multiswitcher • Operation and Setup N The output buttons and the Enter button flashes three times only and then extinguishes. The Enter button must be pressed befor e it becomes unlit. If it extinguishes before being pr essed, repeat steps 3 and 4.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-14 An example of creating a set of I/O gr oups In the following example one of the four sets of I/O groups ar e setup. In this example, input’s 3, 4, and 8, and outputs 2, 3, and 8, are to be assigned to I/O gr oup #2.
3-15 ISM 824 Integration Scaling Multiswitcher • Operation and Setup N If after 30 seconds, no buttons have been selected, the device times out and reverts to the default cycle. No inputs or outputs ar e added to any group 5 . Press Menu. This clears the I/O gr oup display and shows the first Menu.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-16 Unmuting an output T o unmute an output signal: 1 . Press the Esc button to clear all pending changes and r eset the LCD. 2 . Press and r elease the V iew button (lights red ).
3-17 ISM 824 Integration Scaling Multiswitcher • Operation and Setup 4 . Press the V ideo button to exit RGB delay mode. The V ideo button ceases ashing, and remains lit gr een, and the Audio button lights red. The V iew , Esc, and output buttons extinguish.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-18 Input audio level (gain) and output audio volume Viewing input audio level and output audio volume The audio level (gain) of each input can be viewed and adjusted through a range of -18 dB to +24 dB, in 1 dB steps.
3-19 ISM 824 Integration Scaling Multiswitcher • Operation and Setup N The input audio level readout on the LCD r emains unchanged. 5 . Press the audio button to exit the audio display and adjust mode. The audio button ceases flashing, and remains lit r ed.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-20 I/O presets Overview The ISM 824 has a total of sixteen I/O preset memory addr esses available.
3-21 ISM 824 Integration Scaling Multiswitcher • Operation and Setup Figure 3-28 — Steps 3 and 4 for saving a pr eset 4 . Press the Enter button. All lights extinguish and the preset (the current configuration) is saved. Recalling a preset T o r ecall a preset do the following: 1 .
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-22 ENTER 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 OUTPUTS INPUTS C O N T R O L PRESET ESC VIEW C O N T R O L PRESET ESC VIEW Step 3. Press and release the desired input or output button (preset) to recall.
3-23 ISM 824 Integration Scaling Multiswitcher • Operation and Setup Adjustment configuration values are shown on the fr ont panel LCD screen, or on the control device display if using RS-232 or Ethernet to make adjustments. N Invalid picture adjustments for any input/output combination shows N/A instead of the configuration values.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-24 Figure 3-34 — Steps 1 and 2 for adjusting brightness and contrast 3 . Using the left front panel encoder ( [ ), adjust the brightness (0 to 255, default is 128), and with the right ( { ) encoder , adjust the contrast (0 to 255, default is 128).
3-25 ISM 824 Integration Scaling Multiswitcher • Operation and Setup Adjusting the picture position T o adjust the pictur e position do the following: 1 . Press the Esc button to clear all pending changes and r eset the LCD. 2 . Press and r elease the Position adjustment button.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-26 Figure 3-37 — Steps 1 and 2 for adjusting pictur e size 3 .
3-27 ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3 . Use either of the front panel encoders ( [ or { ) to adjust the image zoom. The dimensions of the of the image adjust uniformly . N A setting increment makes the image lar ger , and a setting decrement shrinks the image.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-28 • Executive Mode 2 — I/O ties only . In this mode partial fr ont panel lockout is achieved, allowing ties to be changed, I/O presets r ecalled, button background illumination control, and audio gain/attenuation contr ol.
3-29 ISM 824 Integration Scaling Multiswitcher • Operation and Setup ISM 824 Menu System The ISM 824 has a six level menu system. Access to each level and sub-level is made by using the menu control buttons. • Menu button — The Menu button enters and moves through the main menu system in the ISM.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-30 Default Cy cl e Menu Menu Menu Ne xt Au to Imag e Inpu t Co nguration 30 sec . 30 sec . 30 sec . Rotate either encoder to scr oll through outputs #3 through #8, or press the desired button.
3-31 ISM 824 Integration Scaling Multiswitcher • Operation and Setup N When the sub level is entered, the last selected input lights steady gr een. All other input buttons flash green. 3 . Select the desired input by pr essing its button. That button lights green, and all other buttons flash green.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-32 Default Cycle Menu Menu Menu Menu Au to Imag e Output Ca rd Configuration Next Men u 30 sec.
3-33 ISM 824 Integration Scaling Multiswitcher • Operation and Setup Select Output submenu This submenu allows selection of any installed Universal Scaler outputs to be configured using further submenus. T o select an output to configure, do the following: 1 .
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-34 Output Cong submenu W ithin this submenu, the resolution, the refr esh rate, the output signal type, and the sync polarity can be selected and adjusted.
3-35 ISM 824 Integration Scaling Multiswitcher • Operation and Setup 5 . Press Next to r eturn to the upper level Output Config. menu. 6 . Press Menu to go to the next submenu (User Pr esets). User Presets submenu W ithin this submenu, up to 3 presets can be saved or erased.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-36 Advanced Cong submenu W ithin this submenu auto image can be turned on or off, test patterns can be selected. In addition, blue mode, auto memory , lm mode, and RGB passthrough can be all turned on or off separately .
3-37 ISM 824 Integration Scaling Multiswitcher • Operation and Setup Figure 3-48 — Output configuration menu for Video Scaler car d Default Cycle Menu Menu Menu Menu A u t o Image Output Card Configuration Ne xt Me nu 30 sec.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-38 Select Output submenu This menu allows selection of any congurable V ideo Scaler outputs installed to be configured using further submenus. T o select an output to configure, do the following: 1 .
3-39 ISM 824 Integration Scaling Multiswitcher • Operation and Setup 4 . Press Next to enter the next submenu, Sync Polarity . W ithin this submenu, the Sync Polarity can be set (H- V -, H+ V -, H+ V+, or H- V+). Rotate either front panel encoder to select the output signal type .
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-40 3 . Press Next to go to the T op and Bottom Blanking menu. W ithin this menu the top and bottom blanking area (0-255) shown on the display output can be adjusted.
3-41 ISM 824 Integration Scaling Multiswitcher • Operation and Setup View Comm Settings menu The fourth menu level, V iew Comm Settings is reached by pressing the Menu button four times from the default display cycle, or if at a dif ferent menu, by pressing the button r epeatedly times until this menu is shown on the LCD screen.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-42 Editing the communication settings To edit the communication settings, do the following: N The hardware addr ess (the MAC address) is hard coded and cannot be changed.
3-43 ISM 824 Integration Scaling Multiswitcher • Operation and Setup System Reset Menu This fifth menu level is reached by pr essing the Menu button five times from the default display cycle, or until the System Reset menu is shown in on the LCD screen.
Operation and Setup, cont’d ISM 824 Integration Scaling Multiswitcher • Operation and Setup 3-44 Resetting the Unit with the Reset Button There ar e four reset modes (number ed 1, 3, 4, and 5 for the sake of comparison with Extron IPL products) that you can access by pressing the Reset button on the rear panel.
4 Chapter Four SIS ™ Pr ogramming and Control RS-232/RS-422 Link Front Panel Configuration Port Ethernet Link Symbols Switcher-Initiated Messages Host-to-Switcher Instructions Switcher Error Respon.
ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-2 SIS ™ Pr ogramming and Contr ol RS-232/RS-422 Link The switcher ’s rear panel Remote 9-pin D female connector (.
4-3 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Ether net Link The rear panel Ethernet connector on the switcher (gur e 4-3) can be connected to an Ethernet LAN or W AN. This connection makes SIS contr ol of the switcher possible using a computer connected to the same LAN or W AN.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-4 ] = CR /L F ( c ar ri ag e r etu r n/ li ne fe ed) (h ex 0D 0 A) } = CR (n.
4-5 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Switcher -Initiated Messages When a local event such as power -up or a front panel operation occurs, the switcher responds by sending a message to the host. The switcher -initiated messages are listed below and on the following pages.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-6 X@ Vsz X! * X1& ] A front panel vertical size adjustment has occurred. X! is the input, X@ is the output, and X1& is the size variable.
4-7 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Host-to-Switcher Instructions The multiswitcher accepts SIS commands through its serial ports and/or its LAN port. SIS commands consist of one or more characters per command field.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-8 Command/Response T able for SIS Commands Command ASCII (T elnet) (host to .
4-9 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (hos.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-10 Command/response table for SIS commands (continued) Command ASCII (T elne.
4-11 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description View output mutes V iew output mutes Esc VM } W VM | X5! X5! X5! X5! .
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-12 Command/response table for SIS commands (continued) Command ASCII (T elne.
4-13 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description Query firmware version Q/q Q/q V er01*x.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-14 Command/response table for SIS commands (continued) Command ASCII (T elne.
4-15 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (ho.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-16 Command/response table for SIS commands (continued) Command ASCII (T elne.
4-17 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (ho.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-18 Command/response table for SIS commands (continued) Command ASCII (T elne.
4-19 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Additional description RGB delay time Set Delay 3* X@ * X3& # 3%2A X@ %2A X3& # X@ Dly X3&] Set RGB delay .
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-20 Command/response table for SIS commands (continued) Command ASCII (T elne.
4-21 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (ho.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-22 Command/response table for SIS commands (continued) Command ASCII (T elne.
4-23 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (ho.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-24 Command/Response T able for IP SIS Commands Symbol denitions X7) = Swi.
4-25 ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol Command ASCII (T elnet) (host to switcher) URL Encoded (Web) (host to switcher) Response (switcher to host) Addition.
SIS ™ Pr ogramming and Control, cont’d ISM 824 Integration Scaling Multiswitcher • SIS ™ Programming and Contr ol 4-26 Command/response table for SIS commands (continued) Command ASCII (T elne.
ISM 824 Integration Scaling Multiswitcher 5 Chapter Five ISM 824 Multiswitcher Softwar e ISM 824 Windows Control Program Button Label Generator.
ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-2 ISM 824 Multiswitcher Softwar e ISM 824 Windows Contr ol Program The W indows-based Extron ISM 824 Control Pr ogram, wh.
5-3 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 4 . Follow the on-screen instructions. By default, the W indows installation of the Matrix Switchers Control Pr ogram creates a C:Pr ogram FilesExtron ISM 824, and it places three icons into a gr oup folder named “Extron ElectronicsMatrix Switchers.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-4 Using the software The items found in the ISM 824 Control Pr ogram are also a.
5-5 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software N If you logged on using the user password, the Windows pr ogram connects you to the ISM 824 multiswitcher with only user capabilities. If a password was requir ed and not entered or if an incorr ect password was entered, the pr ogram prompts for the password.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-6 Control pr ogram menus and pages Extron ISM 824 Contr ol Program (gur e 5-5) emulates some of the front panel features of the ISM 824 multiswitcher .
5-7 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software • Data T racer — Selecting this opens a small window in which the transmit and receive (Tx/Rx) data between the contr ol software on the host PC and the ISM 824 can be viewed in ASCII format (see figure 5-8).
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-8 • Executive mode — The Executive mode locks out some or all of the front panel features, and has thr ee levels. Select the mode level applicable.
5-9 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 3. Click Take . The groups ar e now made (see figure 5-1 1). Figure 5-11 — ISM 824 I/O gr ouping completed N T o clear all groups click Clear All .
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-10 • Unit Settings — Click on this to open the settings window . This window has two tabs, IP and RS-232, each of which shows the setting for the host contr oller connection to the ISM 824 (see figure 5-13).
5-11 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software N All ties and user settings are lost when the ISM r estarts, and the unit reverts to factory defaults. • Updating Firmware — T o update the ISM 824 firmwar e using the configuration utility , do the following: 1 .
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-12 Figure 5-16 — Advisory window for RS-232/RS-422 connection uploads 5 . Upon completion, the Firmware Loader window indicates the ISM is restarting.
5-13 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software I/O control page Selecting the rst tab, opens the I/O Control page. Upon opening, this page shows the current configuration for input to output ties, video/audio tie modes (follow all or breakaway), and output mute status.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-14 Muting or unmuting output signals T o mute or unmute output video signals, audio signals, or both do the following: 1 .
5-15 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software N Clicking Cancel in the I/O Preset window (figur e 5-21, right image), at any time before completing Step 3 , closes that window and r everts back to the I/O Presets window (figur e 5-21, left image), without saving to any preset.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-16 Conguring the input video signal type T o configur e the input video type, do the following: 1 . Click on the drop down box of the input number to be configur ed (see Figure 5-24).
5-17 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software Setting the RBG delay T o set the RGB delay , do the following: 1 . Click in an output RGB Delay eld where delay (in 0.1 seconds intervals) is to be changed. Up and down scroll arr ows appear (see gure 5-26).
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-18 Adjusting the input gain and attenuation T o adjust the input gain and attenuation, do the following: 1 . Click the input which is to be adjusted.
5-19 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software Output Cards page Selecting the fourth tab opens the Output Cards page, which allows the user to individually congure up to four output car ds. Each installed congurable card has a radio button next to the name.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-20 Making input to output ties T o make input to output ties, do the following: 1 . Click the input drop down box and select the input to be tied to the curr ent card.
5-21 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 2 . Select a test pattern from the list by clicking on it. The test pattern becomes the current image. N If a 4:3/16:9 Film Aspect Ratio (1.33 through 2.35) is selected, it superimposes the sizing box over the current image.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-22 2 . Scroll to and click on the desir ed preset number . The pr eset field shows the number selected. 3 . Click Recall to recall the selected pr eset.
5-23 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software N Each input to any output card can have different pictur e adjustments settings. The image control default settings ar e 50% of the min/max (see figure 5-31). Some values may be auto detected (e.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-24 Selecting blue mode, 2:2 Pull down, Edge smoothing lter , Auto image,or E.
5-25 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software Recalling an input preset T o r ecall an input preset, do the following: 1 . Click the drop down arr ow in the presets field. A list of presets (1 thr ough 128) appears.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-26 Button Label Generator The Button Label Generator software cr eates labels that can be placed in the translucent covers of front panel buttons.
5-27 ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 3. W ithin this window , click on a desired button to edit. A red squar e appears over the button in which text (2 characters maximum on input and output buttons) can be typed.
ISM 824 Multiswitcher Softwar e, cont’d ISM 824 Integration Scaling Multiswitcher • ISM 824 Multiswitcher Software 5-28.
ISM 824 Integration Scaling Multiswitcher 6 Chapter 6 HTML Operation Downloading the Startup Page System Status Page Configuration Pages File Management Page Control Pages Special Characters.
ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-2 HTML Operation The multiswitcher can be controlled and operated thr ough its LAN port, connected via a LAN or W AN, using a web br owser such as Microsoft’s Internet Explor er or the Firefox br owser .
6-3 ISM 824 Integration Scaling Multiswitcher • HTML Operation • Is there a file in the switcher ’s memory that is named “index.html”? If so , the switcher downloads “index.
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-4 Conguration Pages Click on the Configuration tab, to download the ISM’s configuration pages. These pages gives access to the system settings, ISM settings, passwords, email settings, and to the Firmware Upgrade facility .
6-5 ISM 824 Integration Scaling Multiswitcher • HTML Operation DHCP radio buttons The DHCP On radio button dir ects the ISM to ignore any enter ed IP addr esses and to obtain its IP addr ess from a Dynamic Host Conguration Pr otocol (DHCP) server (if the network is DHCP capable).
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-6 System Settings page – Date/Time Settings elds The Date/T ime Settings fields (figure 6-4) provide a location for viewing and setting the time functions. The adjustable variables are month, day , year , hours, minutes, AM/PM, and (time) zone.
6-7 ISM 824 Integration Scaling Multiswitcher • HTML Operation Figure 6-5 — ISM Settings page Input conguration Each input eld has a drop down box associated with it.
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-8 Executive mode The Executive Mode section has three selectable levels; • Off – full front panel access and menus ar e available • V iew only – ties cannot be created or br oken and menus are not available.
6-9 ISM 824 Integration Scaling Multiswitcher • HTML Operation For the e-mail settings and for each row of the e-mail notification settings, click Edit to make the elds available for editing (see gure 6-7). The button changes to Save. After editing the settings associated with the Edit/Save button, click Save .
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-10 3 . Enter a user name and a password in the User Name and Passwor d elds. For the ISM to accept their e-mail messages, senders must enter the user name and password.
6-11 ISM 824 Integration Scaling Multiswitcher • HTML Operation 2 . Click the Firmware link (figure 6-9). Figure 6-9 — Location of firmwar e upgrade files on the Extron web site 3 . Select the ISM 824 firmwar e file to download and save it to the host PC.
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-12 File Management Page T o delete files such as logo bitmaps fr om the multiswitcher or to upload your own HTML les to the device, click the File Management tab.
6-13 ISM 824 Integration Scaling Multiswitcher • HTML Operation Contr ol Pages T o access the Contr ol pages, click the Control tab fr om any other page.
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-14 3 . Click Take to make the tie. The page refr eshes, the letter P disappears fr om the button and the ISM 824 is updated with the new tie. T o r emove ties, do the following: 1 .
6-15 ISM 824 Integration Scaling Multiswitcher • HTML Operation T o mute or unmute a signal, do the following: 1 . In the signal type field, click Video only , Audio only , or Video & Audio depending on the signal type to be muted 2 . Click Mute for the output to be muted.
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-16 I/O Presets page T o access the I/O Pr esets page, click on the I/O Presets link on the left side of any of the Control pages. The page opens showing the curr ent saved presets.
6-17 ISM 824 Integration Scaling Multiswitcher • HTML Operation 3 . Enter a suitable name (maximum 1 1 characters, including spaces) in the name field. 4 . Click Accept to name the preset. The page r efreshes and the selected button shows the entered name.
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-18 Also from this page adjustments to the following can be made; • picture controls (color , tint, contrast, b.
6-19 ISM 824 Integration Scaling Multiswitcher • HTML Operation Video Scaler — ISM VS The page for the V ideo Scaler is shown below: Figure 6-18 — Video Scaler output car d configuration screen On the top of this page, the input number that is currently tied to the car d’s output tie is shown (see figure 6-18).
HTML Operation, cont’d ISM 824 Integration Scaling Multiswitcher • HTML Operation 6-20 T o save and r ecall presets do the following: 1 . Select either the User presets or Input pr esets drop down arr ows as desired (see figure 6-18). N There ar e 3 user presets and 128 input pr esets.
ISM 824 Integration Scaling Multiswitcher A Appendix A Ether net Connection Ethernet Link Subnetting — A Primer.
Ether net Connection A-2 ISM 824 Integrated Scaling Multiswitcher • Reference Information Ether net Link The rear panel Ethernet connector on the ISM 824 can be connected to an Ethernet LAN or W AN. This connection makes SIS contr ol of the switcher possible using a computer connected to the same LAN.
A-3 ISM 824 Integrated Scaling Multiswitcher • Reference Information Ping the switcher as follows: 1 . On the W indows task bar , click Start > Run. 2 . At the Open prompt, type command. 3 . Click the OK button. 4 . At the DOS prompt, type ping {IP addr ess} and then press Enter .
Ether net Connection, cont’d A-4 ISM 824 Integrated Scaling Multiswitcher • Reference Information Figure A-3 — T elnet screen T elnet tips It is not the intention of this manual to detail all of the operations and functionality of T elnet; however , some basic level of understanding is necessary for operating the ISM 824 via T elnet.
A-5 ISM 824 Integrated Scaling Multiswitcher • Reference Information Local echo Once connected to the ISM 824, by default, T elnet does not display your keystr okes on the screen. SIS commands ar e typed in blindly and only the SIS responses ar e displayed on the screen.
Ether net Connection, cont’d A-6 ISM 824 Integrated Scaling Multiswitcher • Reference Information Subnetting — A Primer It is not the purpose of this manual to describe TCP/IP protocol in detail.
A-7 ISM 824 Integrated Scaling Multiswitcher • Reference Information Determining whether devices are on the same subnet T o determine the subnet, the local device’s IP address is compared to the r emote device’s IP addr ess (figure A-6).
Ether net Connection, cont’d A-8 ISM 824 Integrated Scaling Multiswitcher • Reference Information.
ISM 824 Integration Scaling Multiswitcher B Appendix B Refer ence Information Specifications Part Numbers and Accessories.
Refer ence Information, cont’d ISM 824 Integration Scaling Multiswitcher• Reference Information B-2 Refer ence Information Specications Video Routing ........................................... 8 x 2 matrix up to 8 x 8 matrix, depending on model and configuration Gain .
B-3 ISM 824 Integrated Scaling Multiswitcher • Reference Information Video output — ISM RGB universal scaler boar d (70-544-01) scaled outputs Number/signal type ..................... 1 scaled or pass-through RGBHV , RGBS, RGsB, HD digital component video (YUV) Connectors .
Refer ence Information, cont’d ISM 824 Integration Scaling Multiswitcher• Reference Information B-4 Sync — ISM VS Input type ...................................... Pass-through RGBHV , RGBS, RGsB Output type .................................... RGBHV , RGBS, RGsB Bi-level on Y , R-Y , B-Y channels (component video) Standards .
B-5 ISM 824 Integrated Scaling Multiswitcher • Reference Information Ethernet protocol ........................... ARP , ICMP (ping), TCP/IP , T elnet, HTTP Default settings .............................. Link speed and duplex level = autodetected IP addr ess = 192.
Refer ence Information, cont’d ISM 824 Integration Scaling Multiswitcher• Reference Information B-6 Part Numbers and Accessories ISM 824 part number Switcher model Part number ISM 824 60-787-01 In.
Extr on’ s W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of thr ee years from the date of pur chase.
Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517 Extron Electronics, Europe Beeldschermweg 6C 3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050 Extron Electronics, Japan Kyodo Building, 16 Ichibancho Chiyoda-ku, T okyo 102-0082 Japan +81.
Een belangrijk punt na aankoop van elk apparaat Extron electronic ISM 824 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Extron electronic ISM 824 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Extron electronic ISM 824 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Extron electronic ISM 824 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Extron electronic ISM 824 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Extron electronic ISM 824 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Extron electronic ISM 824 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Extron electronic ISM 824 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.