Gebruiksaanwijzing /service van het product 20i-T B van de fabrikant Fagor America
Ga naar pagina of 32
Fagor Automation S. Co op. 20i-T / 30i-T 20i-T B / 30i-T B Installation/Operation Manual Manual code: 14460054 Manual version: 0612 Software v ersion: 4.
(2/32) - Installation/Oper ation - 20i-T / 30i-T - V0612 INDEX 1 DRO description ........................... ................. .................. ............... ............. 3 1.1 Front panel ................................... .....................
V0612 - 20i-T / 30i-T - Installation/Operation - DRO description - (3/32) 1 DRO description 1.1 Front p anel Each axis display has eight 1 4.1mm high LEDs and another one for the minus sign (-). Description of LED's and keys: ABS It stays on when operating in absolute mode and off when in incremental mode.
(4/32) - DRO description - Installation/Operation - 20i-T / 30 i-T - V0612 1.2 T urning the unit on and off It turns on automatically when applying voltage or after pressing the on/off key. It shows Fagor dro or the corresponding error code. See the error table and PAR11 for more options.
V0612 - 20i-T / 30i-T - Installation/Operation - DRO oper ation - (5/32) 2 DRO operation 2.1 Display modes MM / INCH conversion To display the position of the axes eit her in millimeters or inches by pressing this key depending on whether the INCH led is off or on respectively.
(6/32) - DRO opera tion - Installation/Operation - 20i-T / 30i-T - V0612 2.2 Incremental, absolute and with respect to Machine Reference Zero This DRO shows the current position of two or three axes (20i-T / 3 0i-T). Coordina te means the dis tance from one point or po sition with resp ect with another chosen as refer ence.
V0612 - 20i-T / 30i-T - Installation/Operation - DRO oper ation - (7/32) 2.2.1 Example Using the lower figure, let us imagine we wish to make a part in which three holes have to be drilled with the coordinates sta ted.
(8/32) - DRO opera tion - Installation/Operation - 20i-T / 30i-T - V0612 - Once this turning ope ration has concluded, one can go to the next position, after having preset th e next coordinate (25.00 0), by moving the axis until the display reads 0.000.
V0612 - 20i-T / 30i-T - Installation/Operation - DRO oper ation - (9/32) 2.3 Machine Reference selection and search Although it is not absolutely necessary, it is recommend ed to use the reference marks (Io) of the feedback system in order to set a machine zero point.
(10/32) - DRO operation - Installation/Operation - 20i-T / 30i-T - V06 12 2.4 Operation with tools 2.4.1 T ool Preset Up to 20 tools may be preset on this DRO model (from "tool 0" to "tool 19 "). The unit stores in its internal memo ry the relative offsets of all the tools with respect to that of "T0".
V0612 - 20i-T / 30i-T - Installation /Operation - DRO operation - (11 /32) 2.5 S pecial operations 2.5.1 Scaling fact or It is possible to apply a scaling factor within ±9.999 for mold making applications: The DRO will then show the axis positi on resulting from multiplying its real position by the 'value' of the scaling factor.
(12/32) - DRO operation - Installation/Operation - 20i-T / 30i-T - V06 12 T ool change at any known point of the part: - Touch the part with the tool. - Go into HOLD mode. The reading for t hat axis freezes with the current value. - Remove the tool to b e replaced and insert the new one.
V0612 - 20i-T / 30i-T - Installation /Operation - DRO operation - (13 /32) 2.5.5 Calculat or This feature may be used to carry out mat hematical and trigonomet ric operations as well as prese t the desired axis with the result of the calculation or use the coordinates o f the axes to carry out math o perations.
(14/32) - DRO operation - Installation/Operation - 20i-T / 30i-T - V06 12 2.5.5.2 Recall and Reset modes Toggles between the recall a nd Preset modes. RECALL mode The recall mode lets en ter the current axis position into the calculator . Enters the current positio n of the selected axis into t he calculator.
V0612-20i-T / 30i-T - Installation/Operation - DRO insta llation - (15/32) 3 DRO installation 3.1 Inst allation of the built-in model Dimensions of the enclosure hole for inserting the DRO Built-in DR.
(16/32) - DRO installation - In stallation/Operation - 20i-T / 30i- T - V0612 3.2 Rear panel On the back of the unit the following items may be found: 1. Three-prong power connector for AC and ground connection. 2. M6 mm terminal for ge neral machine ground connectio n.
V0612-20i-T / 30i-T - Installation/Operation - DRO insta llation - (17/32) WARNING Do not handle the connecto rs while the unit is under power. Before handling the conn ectors (mains, feedback, etc.) m ake sure that the unit is not under power. It is NOT enough to turn th e display off by using the [on/off] key at the keyboard 3.
(18/32) - DRO installation - In stallation/Operation - 20i-T / 30i- T - V0612 3.5 Easy setup The "Easy Setup" may be used to set up the feedback of the DRO and to verify that the installation is correct and no feedback pulses a re missed.
V0612-20i-T / 30i-T - Installation/Operation - DRO insta llation - (19/32) The axis status w ill then switch to o ne of the following: Ready Correct feedback setup Repeat Wrong feedback setup, the process should be repeated. Error Error in the feedback system .
(20/32) - DRO installation - In stallation/Operation - 20i-T / 30i- T - V0612 T o get into parameter editing The dro displays must be on, re ading mode and press the following keys: The X axis display shows the wor d " COdE ". 060496 The displa ys of the DRO sh ow PAR00 .
V0612-20i-T / 30i-T - Installation/Operation - DRO insta llation - (21/32) 3.7 Parameters to configure axis position reading and display . The digits of digital parameters refer to the digits on the a.
(22/32) - DRO installation - In stallation/Operation - 20i-T / 30i- T - V0612 P AR02 TTL multi plying factor (subd ivision). Independent for ea ch axis. Options: x4, x2, x1 and x0.5. The factory setting is x4 and it is the one used for FAGOR linear encoders.
V0612-20i-T / 30i-T - Installation/Operation - DRO insta llation - (23/32) PA R 0 4 Axis display. Indepe ndent for each axis. Digit 8, 7, 6, 5, 4 Not being used at th is time (they must be set to "0 "), 3 Turn the axis d isplay off . 0 = No, 1 = Yes.
(24/32) - DRO installation - In stallation/Operation - 20i-T / 30i- T - V0612 Therefore, when usin g standard Io's, this pa rameter must be assigned the value of the distance from the m achine zero point to the feed back reference point. Numeric value in resolution units for each axis.
V0612-20i-T / 30i-T - Installation/Operation - DRO insta llation - (25/32) PA R 1 5 Multi-point l eadscrew error comp ensation. Import ant: Before capturing data for an acc uracy graph, the axis ( axes) must be homed (referen ced) because the compensation will not be applied until they are homed.
(26/32) - DRO installation - In stallation/Operation - 20i-T / 30i- T - V0612 Select the desired axis and enter the number of points to be used fo r the axis, up to 40. Zero means t hat there is no compensat ion table for the axis. Where “ POS 1 ” is the point number to enter and “ ERROR 1 ” the amount of error to be compensate d.
V0612 - 20i-T / 30i-T - Installation /Operation - Appendix - (27/32) 4 Appendix 4.1 UL seal See "UL seal" page 16. 4.2 CE seal Warning Before starting up the DRO, carefully read the instructions of Chapter 2 in the Installation Manual.
(28/32) - Appendix - Installation/Operation - 20i-T / 30i-T - V06 12 32 4.2.2 Safety conditions Read the following safety m easures in order to pr event damage to personnel, to this product and to those products connected to it.
V0612 - 20i-T / 30i-T - Installation /Operation - Appendix - (29/32) It is recommended to mount the DRO vertically , so its power switch of the back panel is at a distance between 0.7 m (27.5 inches) and 1.7 m (5.6 ft) off the floor and away fr om coolants, chemical products, blows e tc that could damage it.
(30/32) - Appendix - Installation/Operation - 20i-T / 30i-T - V06 12 32 4.2.3 W arranty t erms W ARRANTY All products manufactu red or marketed b y Fagor Automation has a warranty period of 12 months from the day they are shipped out of our warehouses.
V0612 - 20i-T / 30i-T - Installation /Operation - Appendix - (31/32) 4.3 Error codes If any message other than the first two from the table were to come up, the equipment should be switched off and on a gain until one of the first two are seen. After pressing this key to access t he counting mode, check the par ameters.
(32/32) - Appendix - Installation/Operation - 20i-T / 30i-T - V06 12 32 4.4 Maintenance Cleaning: An accumulation of dirt in the equipment can act as a scr een preventing proper dissipation of the heat gener ated by the internal e lectronic circuits with the consequent danger of overheating and DRO fault.
Een belangrijk punt na aankoop van elk apparaat Fagor America 20i-T B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Fagor America 20i-T B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Fagor America 20i-T B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Fagor America 20i-T B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Fagor America 20i-T B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Fagor America 20i-T B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Fagor America 20i-T B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Fagor America 20i-T B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.