OWNER'S OPERA TING MANUAL Rackmount SG Series UPS Plus ® Uninterruptible Power Supply Models: SG1KRM-1TU, SG1KRM-2TU SG2KRM-1TU, SG2KRM-2TU SG3KRM-1TU, SG3KRM-2TU Det ailed SG Series product specifications are available in PDF format at www .falconup s.
SG UPS Features. ...... 1 SG Series Online UPS Block Diagram. .... 1 Import ant Safety Instructions (READ FIRST) .... 2 Chapter 1. SG Series UPS Overview ..... 3 T rue Regenerative Online Design .... 3 Input Power Factor Correction .... 3 Microprocessor Control .
SG SERIES UPS FEA TURES SG SERIES ON-LINE UPS SYSTEM BLOCK DIAGRAM T rue Double Conversion On-Line Design Input Power Factor Correction Wide Input V oltage W indow Pure Sinewave Output Precision Outpu.
IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains import ant instructions which must be followed during the installation, operation and maintenance of this UPS and its batteries. Please read all instructions before operating this equipment and save this manual for future reference.
CHAPTER CHAPTER 1 1 SG Series UPS - Overview T rue Regenerative On-Line Design As new and innovative technologies have become the backbone of today's businesses, maximum system availability is critical and downtime is more expensive than ever .
CHAPTER CHAPTER 2 2 SG RACKMOUNT INST ALLA TION INSTRUCTIONS 1. V erify the following is included in the UPS shipping carton: * UPS * Software Diskette(s) & Manual *Power Cord * Owners Manual * UP.
c. Install a suit able shelf capable of supporting the weight of the UPS and batteries into the equipment rack. Install the shelf so the UPS and battery bank (if required) will sit directly on the surface of the shelf.
5. For all 1kV A & (-2) 2-3kV A models, connect the power cord to the UPS inlet located on the UPS rear panel. On (-1) 2 & 3Kva models the line cord is permanently attached to the UPS. 6. Connect the power cord(s) for the equipment to be protected to the UPS output receptacles.
7 8. If unattended computer shutdown and monitoring are desired, connect the green UPS/Computer cable to the DB-9 connector located on the UPS rear panel. Then install the shut down and monitoring software provided with the UPS. For your reference, UNIX shutdown and monitoring sof tware is available from Falcon Electric at an additional cost.
8 OPTIONAL SLIDE MOUNTING KIT (SGRMKIT) An slide mounting kit option is available from Falcon Electric. The p art number for the kit is SGRMKIT and may be inst alled on any rackmount UPS and battery bank referenced in this manual.
BA TTERY OPTION MOD EL SG1KRM -1T SG B R2S7 -1K U SGBR2S7 -1K U SGB R2S 7 -1K U SG B R2S7 -1K U BA TTERIES 7AH x 3 7AH x 6 (7 A H x 6 ) x 2 (7 A H x 6 ) x 3 (7 A H x 6 ) x 4 BA TTERIES IN UP S Batteri es & UPS in same ca se 7AH x 3 7AH x 3 7AH x 3 7AH x 3 # OF BA TTERY CA SE S UPS 1 2 3 4 RUN TIME @ 100W 54 Min.
10 CHAPTER CHAPTER 3 3 OPERA TION 1 2 3 4 5 6 7 8 9 10 11 UPS FRONT P ANEL INDICA T OR AND FUNCTION KEYS 1. LOAD LEVEL INDICA T OR LEDS *The first or bottom LED is lit when the output load is greater than 25% of the rated output of the UPS. *The second LED is lit when the output load is greater than 50% of the rated output of the UPS.
5. BYP ASS INDICA T OR LED When this LED is lit the UPS bypass is active. Should the Alarm LED be lit at the same time, the UPS detected an internal failure and the UPS must be serviced. 6. INVERTER INDICA T OR LED When this LED is lit, the UPS inverter is operating and powering the connected load.
AUDIBLE ALARMS Audible alarm signals are divided into two different levels of alarm st atus. Category one alarms represent normal or correctable operational alarms. Category two alarms are sounded in the event of abnormal operation. 1. Category one alarms : a.
13 CHAPTER CHAPTER 4 4 FRONT & REAR P ANEL DET AILS SG1KRM-1TU T ypical Rear Panel Overview SG1KRM-2TU T ypical Rear Panel Overview Power Cord Inlet (120V ac only) Input Fuse (15A) Cooling Fan Out.
SG2KRM-1TU & SG3KRM-1TU T ypical Rear Panel Overview 14 SG2KRM-2TU & SG3KRM-2TU T ypical Rear Panel Overview Output Circuit Breaker (lower 2 receptacles) Cooling Fan RS-232 Port Output Recepta.
CHAPTER CHAPTER 5 5 COMMUNICA TIONS INTERF ACES RS-232 INTERF ACE 15 P in # Function explan ation I/O 9 RS 232 Rx INP UT 6 RS 232 Tx OUT PUT 7 Gr ound Location: The RS-232 interface is standard on all SG series UPS models. The port is located on the UPS rear panel, via a DB-9 female connector .
16 DR Y CONT ACT & OPTO COUPLER INTERF ACE BOARD OPTIONS JP1 JP2 JP3 J1 J2 J3 DB- 9 T ypical Falcon Dry Contact Relay Board PIN DESCRIP TION 1 Low Battery ( When UPS reaches low battery, c ontact acti vates) (J1, 1-2 short = N.O) (J1, 2-3 short = N.
17 PIN ASSIGNMENT FOR THE F ALCON UA88373 OPTO-COUPLER OPTION BOARD (no-byp ass signal) PIN DESCRI PTIO N 1 Not Used 2 Uti lity Los s ( N.O.) ( C l os es upon uti li t y loss) 3 Utili t y Loss ( N.C. ) ( Opens upon util it y loss) 4 Comm on for pins 2, 3 & 5 5 Lo w Batte ry (N .
CHAPTER CHAPTER 6 6 Maintenance & T echnical Support 1. Care & Maintenance Falcon ® SG Series UPSs are designed to be maintenance-free. They can be cleaned with a damp cloth or non-abrasive cleanser , providing the UPS is turned off and the input plug is disconnected from the utility source.
The following precautions should be observed by a qualified technician when working with batteries. 1. Remove watches, rings, or other metal object s. 2. Use tools with insulated handles. 3. Wear rubber gloves and boot s. 4. Do not lay tools or metal p arts on top of batteries.
6. T echnical Support Y our F ALCON ® Electric SG Series UPS is backed by one of the finest customer service teams assembled. Write, call, fax or email should you require technical assistance or service. Falcon Electric Inc. 5106 Azusa Canyon Road Irwindale, CA.
21 GENERAL PROVISIONS F ALCON® ELECTRIC INC., hereby warrants product shipped under this agreement to be free from defective workmanship for a period of two years following date of shipment. This Limited New Product W arranty Agreement only applies to covered repairs to the product occurring within the United S tates and Canada.
SG Series TM UPS PLUS ® 1kVA to 3kVA 22 Model Nu mber SG1KR M -1TU SG1KR M -2TU SG2KR M -1TU SG2KR M -2TU SG3KR M -1TU SG3KR M -2TU Nominal VA 1000 2000 3000 Electric al I nput Nominal AC Voltage 120V 230V 120V 230V 120V 230V AC Voltage Range 87- 140V 170 -275V 87- 140 V 170 -275V 87-140V 170 -275V Current - Am ps 6.
Een belangrijk punt na aankoop van elk apparaat Falcon SG2KRM-2TU (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Falcon SG2KRM-2TU heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Falcon SG2KRM-2TU vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Falcon SG2KRM-2TU leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Falcon SG2KRM-2TU krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Falcon SG2KRM-2TU bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Falcon SG2KRM-2TU kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Falcon SG2KRM-2TU . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.