Ultra Quiet Series Electric Air Handler 11⁄2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz

The Fedders multi-position air handlers, when matched with our air conditioners or heat pumps, offer a complete line of quiet, efficient split systems for today’s heating and cooling equipment.

Easy To Install And Service

Breaker accessible from front of unit when heater applied

External Access to heater circuit breakers pull /disconnects

Dual rated 208/230 volt operation

Provisions for field installed electrical connections from either side of air handler cabinet

1 1 ⁄ 2 to 5 tons

External sweat refrigerant connections

Built in filter rack

TXV – factory installed standard, which precisely controls refrigerant distribution for improved comfort and cost savings

Pressure taps on suction and liquid line Corrosion resistant condensate drain pan. Primary and secondary drain

Standard Features Multiposition installation, upflow or horizontal left standard, horizontal right and downflow with minor modifications

Optional Features

3-speed, permanently-lubricated PSC direct drive blower motor is resilient mounted for ultra quiet, vibration-free operation and flexible installation

Field installed heater packages from 5 kW – 20 kW

Warranty

Foil faced insulation reduces noise and bacterial growth and features an easy to clean surface area

5-year limited parts warranty

All indoor coils have copper tubing and aluminum fins

Rated in Accordance with ARI Standard 210/240. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org

Time Delay relay comes standard and allows for retro-fit installations

3/4" primary and secondary drains on all models

Fedders AFPB36A1 — Time Delay relay comes standard and allows for retro-fit installations diagram (page 1)
Afb. 3 · Time Delay relay comes standard and allows for retro…
MODELTONSREFRIGERANTAIR FLOW RANGE (CFM)DIMENSIONS H x W x D (in)RECOMMENDED S FILTER SIZE OPER H x W x D (in) WEIG AFPB24A11.5 - 2R-22625 – 90043 3/8 x 18 x 2216 x 20 x 1 115 AFPB24B11.5 - 2R-22615 – 88043 3/8 x 18 x 2216 x 20 x 1 12 AFPB36A12.5 - 3R-22950 – 1,26043 3/8 x 18 x 2216 x 20 x 1 12 AFPC48A13.5 - 4R-221,190 – 1,59048 3/8 x 22 x 2620 x 25 x 1 161 AFPC48B14R-221,195 – 1,59048 3/8 x 22 x 2620 x 25 x 1 167 AFPC60A15R-221,340 – 1,89548 3/8 x 22 x 2620 x 25 x 1 167 AZFPC60B15R-410A1,340 – 1,89548 3/8 x 22 x 2620 x 25 x 1 167
Page 2 of the Fedders AFPB36A1 user manual — Clearance to Combustible Material
Pagina 2 · klik om te vergroten
Pagina 2
Fedders AFPB36A1 — Clearance to Combustible Material diagram (page 2)
Afb. 4 · Clearance to Combustible Material
PHYSICAL DATA MODEL NUMBERAFPB24A1AFPB24B1AFPB36A1AFPC48A1AFPC48B1AFPC60A1AZFPC60B1 ELECTRIC DATA (208/230 VOLT, SINGLE PHASE, 60 Hz) VOLTAGE208 / 230208 / 230208 / 230208 / 230208 / 230208 / 230208 / 230 MINIMUM CIRCUIT AMPACITY MCA (AMPS)15151515151515 MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP (AMPS)15151515151515 BLOWER FAN MOTOR TYPEPSC HP1/61/61/31/21/23/43/4 BLOWER DIMENSIONS9 x 79 x 79 x 109 x 89 x 810 x 910 x 9 COIL DATA TYPEA-COIL COIL FACE AREA (ft2)4445.85.85.85.8 O.D.3/8" ROWS / FPI2 - 143 - 143 - 143 - 124 - 123 - 124 - 12 REFRIGERANT LINE CONNECTION LIQUID LINE CONNECTION SIZE (IN. OD)3/83/83/83/83/83/83/8 SUCTION LINE CONNECTION SIZE (IN. OD)3/47/87/87/87/87/87/8 FILTER DATA RECOMMENDED FILTER SIZE (H X W X D) (in) (FILTER NOT SUPPLIED)16 x 20 x 116 x 20 x 116 x 20 x 120 x 25 x 120 x 25 x 120 x 25 x 120 x 25 x 1

Clearance to Combustible Material

Clearances from the air handler to the combustibles are zero inches from all sides, top, and bottom; one inch from discharge air plenum; and the duct within 36 inches of the plenum.

Fedders AFPB36A1 — Clearance to Combustible Material diagram (page 2)
Afb. 5 · Clearance to Combustible Material
Page 3 of the Fedders AFPB36A1 user manual — Clearance to Combustible Material
Pagina 3 · klik om te vergroten
Pagina 3
Fedders AFPB36A1 — Clearance to Combustible Material diagram (page 3)
Afb. 6 · Clearance to Combustible Material
AIRFLOW PERFORMANCE MODEL NUMBERBLOWER SPEEDMEASURED STATIC PRESSURE INLET TO OUTLET (INCHES WATER COLUMN) 0.200.300.400.500.60 HIGH925900850795690 AFPB24A1MEDIUM800760745670N/A LOW655625600N/AN/A AFPB24B1HIGH905880830780680 MEDIUM785735730655N/A LOW645615590N/AN/A AFPB36A1HIGH14401350126011801040 MEDIUM130012201050940860 LOW11601070950880780 AFPC48A1 AFPC48B1HIGH16801640159015201430 MEDIUM14401410138013401250 LOW12401220119011501100 AFPC60A1 AZFPC60B1HIGH22302105199018951725 MEDIUM19501930184017701590 LOW13601360135013401080
Fedders AFPB36A1 — Clearance to Combustible Material diagram (page 3)
Afb. 7 · Clearance to Combustible Material

Specifications applicable to upflow and horizontal applications. Air flow shown at the following conditions:

- No heat elements in Air Handler. Decrease CFM 2% for 5 kW, 7.5 kW or 10 kW heat kits. Decrease CFM 1% for 15 kW or 20 kW heat kits. - 60 Hertz – 230 volts. Decrease CFM 6% for 208 volt operations. - Dry coil airflow shown.

Fedders AFPB36A1 — Clearance to Combustible Material diagram (page 3)
Afb. 8 · Clearance to Combustible Material
Page 4 of the Fedders AFPB36A1 user manual — Accessories
Pagina 4 · klik om te vergroten
Pagina 4

Accessories

ELECTRIC HEATER KITS PART NUMBERDESCRIPTIONUSE WITH MODEL SIZE EEC05N15 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKERALL EEC05B15 KW, SINGLE PHASE, WITH CIRCUIT BREAKERALL EEC07N17.5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKERALL EEC07B17.5 KW, SINGLE PHASE, WITH CIRCUIT BREAKERALL EEC10N110 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKERALL EEC10B110 KW, SINGLE PHASE, WITH CIRCUIT BREAKERALL EEC15B115 KW, SINGLE PHASE, WITH CIRCUIT BREAKERAFPB36A1, AFPC48A1, AFPC48B1, AFPB60A1, AZFPB60B1 EEC20B120 KW, SINGLE PHASE, WITH CIRCUIT BREAKERAFPB36A1, AFPC48A1, AFPC48B1, AFPB60A1, AZFPB60B1
Fedders AFPB36A1 — Accessories diagram (page 4)
Afb. 9 · Accessories
ELECTRIC HEAT - ELECTRICAL DATA kW 240 VACPhaseNo. of Supply CircuitsMBTUH 208/240Heat Load AmpsSINGLE CIRCUIT SUPPLYDUAL CIRCUIT SUPPLY Min. Wire Œ AmpacityMax. Fuse  SizeWire Size ŽGround Size Min. Wire Ampacity ŒMax. Fuse Size Wire Size ŽGround Size Ž AWGMM2AWGMM2Ckt 1Ckt 2Ckt 1Ckt 2Ckt 1 AWG / MM2Ckt 2 AWG / MM2Ckt 1 AWG / MM2Ckt 2 AWG / MM2 011--5.015142.1142.1-------- 5*1114.8 / 17.120.93030105.3105.3-------- 7.5*1122.1 / 25.631.3435088.4105.3-------- 10*1129.5 / 34.141.75760613.3105.3-------- 15*11 or 244.3 / 51.262.58390421.288.4572660306 / 13.310 / 5.310 / 5.310 / 5.3 20*11 or 259.0 / 68.283.4109110233.6613.3575360606 / 13.310 / 13.310 / 5.310 / 5.3

and overcurrent protection size. Minimum wire ampacity values are used for sizing field power conductors. Refer to the National Electrical Code (latest version), Article 310, for sizing conductors. NOTE: when more than three current-carrying conductors are in the same conduit, the conductor's ampacity must be derated.  Maximum size fuse or HACR-type circuit breaker for field wiring protection. Ž Wire size based on 75°C copper wire with no more than three current-carrying conductors in the same conduit.

All wiring must conform to the National Electrical Code and all local codes.

Page 5 of the Fedders AFPB36A1 user manual — VOLTAGE
Pagina 5 · klik om te vergroten
Pagina 5

Product Specifications

Fedders AFPB36A1 — Product Specifications diagram (page 5)
Afb. 10 · Product Specifications

VOLTAGE

KNOCKOUTS

INLET DEPTH

LINE

G

CONNECTIONS

LOW VOLT

E

D

ACCESS COVER

TO TXV

INLET WIDTH

B

F

H

A

DIMENSIONS

Page 6 of the Fedders AFPB36A1 user manual — 410A Refrigerant
Pagina 6 · klik om te vergroten
Pagina 6
Fedders AFPB36A1 — R-22 Models diagram (page 6)
Afb. 11 · R-22 Models

R-22 Models

A F P B 24 A 1 * A

Product Type

A = Air Handler

Brand

Motor P = PSC

Electrical Designation 1 = 208 / 230 Volts, 1 Phase, 60 Hz 2 = 220 Volts, 1 Phase, 50 Hz 3 = 208 / 230 Volts, 3 Phase, 60 Hz 4 = 460 Volts, 3 Phase, 60 Hz 5 = 230 Volts, 3 Phase, 50 Hz 6 = 380 Volts, 3 Phase, 50 Hz

Chassis Size B = 43 3/8"H x 18"W x 22"D C = 48 3/8"H x 22"W x 26"D

Nominal BTUH 24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW) 36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW) 42 = 42,000 BTU/H (12.31 kW) 48 = 48,000 BTU/H (14.07 kW) 60 = 60,000 BTU/H (17.58 kW)

Design Series A = A Series

R-410A Models

A Z F P C 60 B 1 * A

Product Type

Electrical Designation 1 = 208 / 230 Volts, 1 Phase, 60 Hz 2 = 220 Volts, 1 Phase, 50 Hz 3 = 208 / 230 Volts, 3 Phase, 60 Hz 4 = 460 Volts, 3 Phase, 60 Hz 5 = 230 Volts, 3 Phase, 50 Hz 6 = 380 Volts, 3 Phase, 50 Hz

A = Air Handler

410A Refrigerant

Brand

Motor P = PSC

Design Series A = A Series

Nominal BTUH 24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW) 36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW) 42 = 42,000 BTU/H (12.31 kW) 48 = 48,000 BTU/H (14.07 kW) 60 = 60,000 BTU/H (17.58 kW)

Chassis Size B = 43 3/8"H x 18"W x 22"D C = 48 3/8"H x 22"W x 26"D

Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 USA (908) 604-8686 Form No. F-13AH

All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.

Fedders AFPB36A1 — 410A Refrigerant diagram (page 6)
Afb. 12 · 410A Refrigerant

FD-015-0407-k

Vraag stellen over de Fedders AFPB36A1

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Fedders AFPB36A1

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Fedders AFPB36A1 handleiding-pdf

6 pagina's·419 KB·Airconditioner·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…