Gebruiksaanwijzing /service van het product PVU-300 van de fabrikant Field Controls
Ga naar pagina of 16
2630 Airport Road · Kinston, NC 28504 Phone: 252-522-3031· Fax: 252-522 -0214 www.fieldcontrols.com POWER VENTER SYSTEM Mode l: PVU-300 Included is one ETL LISTED po wer venter to be used fo r side wall venting of a single 120/24 VAC controlled furnace, boiler, or water heater which burns natural or LP gas, or oil.
Page 2 UNIT SPECIFICATIONS (See Table 1 and Figure 1 ) Table 1 UNIT DIMENSIONS (INCHES) MODEL “H” “W” “D” I/O* PVU-300 7.5 11.5 7.0 4/4 * Inlet and outlet diameter. ELECTRICAL RATINGS MODEL VAC Hz RPM WATT AM P TP** PVU-300 115 60 3000 145 2.
Page 3 P ROCEDURE F OR C AL CULA TIN G T OTAL E QUIVALENT P IPE L ENGTH I N F EET 1. Calculate the total equivalent feet for each type of fitting used in the v enting system from the following chart. 2. Calculate the total amount of feet fo r the straight lengths of vent pipe.
Page 4 8. Air flow adjustment M U ST be made t o ensure applianc e efficiency. Thi s should be done at the appliance exhaust outlet with a velocity meter, draft gau ge or by the "match test procedure". The match test is in accordance with National Fuel Gas Code A.
Page 5 S IDE W ALL V ENT H OO D I NSTALLATION 1. Use the inside wall plate as a template to mark the hole location. Cut a hole 1 inch larger than the marked hole to facilitate easy insta llation (See Figure 4) 2. Center vent hood through the hole from outsid e.
Page 6 O PTIONAL G SK -3 E XHAUST G AS S PILLAGE D ETECTOR S WITCH I NSTALLATION NOTE: Installation of the GSK-3 secondary safety switch is reco mmended for LP and Natural gas fired appliances with a draft hood. This switch will detect exhaust gas spillage out of the draft hood due to a blocked vent system and/or inadequate draft during operation.
Page 7 GENERAL WIRING INSTRUCTIONS CAUTION: Disconn ect electrical power before wiring p owe r venter! Connect line voltage (110/120 VAC) through j unction box acce ss hole labeled "120 VAC Only". Connect l ow voltage control wiring through ju nction box access hole label ed "24 VAC Control Wiring Only".
Page 8 Diagram E – Wiring with a 30mV Water Heate r NOTE: A CK-20FV or CK-20FG control kit MUST be added to the sy stem to properl y control the venter with the operation of a 30mV water heater.
Page 9 AIR FLOW ADJUSTMENTS 1. To properly adjust the venter air fl ow, loosen the inlet ring screws and open the choke plate approximately 1/2 to 3/4 open. (S ee Figure 9) Start the heating appliance following the manufacturer specified proce dure, and set the thermostat to call for heat.
Page 10 SYSTEM CONTROL CHECK PROCEDURES 1. Adjust the thermostat to cal l for heat and observe th e power ventin g system for proper operation sequence. Repeat as necessary. a. Thermostat calls for heat. b. Venter relay is energized which starts venter motor.
Page 11 Diagram F – Multiple Wiring with 24 VAC Furnace and 30mV Water Hea t e r MULTIPLE VENTING SYSTEMS 1. To vent a 24 VAC controlled boiler or furna c e and a 30 millivolt residential water heater usi ng one PVU power venter refer to the following.
Page 12 Diagram G – Multiple Wiring with two 24 VAC Appliances 2. To vent two 24 VAC appliances using one PVU power venter refer to the following. a.
Page 13 Diagram H – Multiple Wiring with two 120 VAC Appliances 3. To vent two 120 VAC appliances using one PVU power venter refer to the following. c.
Page 14 PV SERIES POWER VENTER: VERTICAL VENTING OPTION Natural gas, lp gas or #2 fuel oil appliance rated at 75% or greater non-co nde nsing type of appliance.
Page 15 VENTING SYSTEM OPERATIONAL INFORMATIO N Date: Heating appliance BTU/Hr input Gas valve operation pressure Vent system draft above draft hood or below barometric draft control CO 2 measurement CO measurement Appliance outlet flue gas temperature INSTALLATION INFORMATION MODEL NO.
Page 16 P/N 46517200 Rev B 11/06.
Een belangrijk punt na aankoop van elk apparaat Field Controls PVU-300 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Field Controls PVU-300 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Field Controls PVU-300 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Field Controls PVU-300 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Field Controls PVU-300 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Field Controls PVU-300 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Field Controls PVU-300 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Field Controls PVU-300 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.