MODELS S2000 AND S2020 FOR GAS OR OIL FORCED AIR FURNACES, HEA T PUMPS AND ELECTRIC FURNACES has been designed to be simple to Install, Operate and Maintain. Read this manual before you install the Humidifier . Parts included in the Steam Humidifier package ar e: 1.
SIMPLIFIED INST ALLA TION INSTRUCTIONS DET AILED INST ALLA TION INSTRUCTIONS 1. Insulate the water reservoir . See figure 3. 2. Select the mounting location on the duct and tape on the mounting template. 3. Drill the (8) 1/8" mountings holes. 4. Cut out the humidifier opening in the duct.
6. W A TER SUPPL Y - Required Criteria 9. WIRING THE STEAM HUMIDIFIER 7. M O U N T I N G T H E S T E A M H U M I D I F I E R 8. STEAM OPERA TION - Required Criteria A. W A TER SUPPL Y USING THE SADDLE V AL VE FURNISHED WITH UNIT . Important! See page 14.
Typi ca l Furnace S2000 & S2020 Humidifier Low V oltage T erminal Block G1 R G2 H H Heat only Thermostat W R G W R Heat Only System and Steam Humidifier with standard dry contact Humidistat Dry Contact Humidistat A A FIG. 6 Factory Jumper will stay in place unless a field installed Air Proving Device is used.
8 . 0 0 ” 6 . 00 ” 7.50” 8 . 2 5 ” 1 0 . 5 0 ” 1 1 . 6 0 ” the room needed to install the unit in a certain location. The data can also be used to determine the minimum duct size the Steam Humidifier can be inserted into. The Steam Humidifier should not obstruct more than 25% of the cross sectional area of the selected duct.
F o r R e p l a c e m e n t P a r t s C a l l ( 8 0 0 ) 4 4 6 - 3 1 1 0 0 9 0 2 1 A 0 1 1 8 U . S . P A T E N T N U M B E R 5 7 5 8 0 1 8 s e r i a l n u m b e r E w c 3 8 5 H i g h w a y 3 3 , E n g l i s h t o w n , N J 0 7 7 2 6 C O N T R O L S , I N C .
It is recommended that humidistat settings of 30-45% not be exceeded. If condensation is noticed on windows during very cold outside temperatures, the humidistat setting should be lowered.
INITIAL ST AR T -UP * SEQUENCE OF OPERA TION * SER VICE “LED” INDICA TORS 1 1. ST AR T -UP & OPERA TING SEQUENCE Once the Steam Humidifier has been installed and the w a t e r, d r a i n , h u m i d i s t a t a n d b l o w e r i n t e r l o c k connections completed, the humidifier may be started.
14. SERVICE INDICA T ORS Seven LED lamps provided on the front panel indicate the functional status of the humidifier as shown in Figure 7 below . 9 A. L. M. N. O. B. C. D. E. F . G. H. I. J. K. Unplug the power cord from the 120 volt source for S2000 (240 volt for S2020) and allow the water to cool for at least 30 minutes prior to removal.
10 A. G. B. C. D. E. F . The green "Power" light does not blink off and on. 1. The S2000 is not connected to an active 120 V AC 15 Amp power source. (S2020, 240 V AC, 10 AMP). 2. Call the T echnical Support Hotline. The "HEA TER" LED does not illuminate.
SERVICE AND REPLACEMENT P ARTS 11 ITEM 1 120 VOL T HEA TER A SSEMBL Y 240 VOL T HEA TER A SSEMBL Y 24 VOL T SOLENOID V AL VE A SSEMBL Y W A TER LEVEL PROBE A SSEMBL Y THERMISTOR PROBE A SSEMBL Y CIRCU.
Figure 18 12 DRAIN COCK V AL VE "T" ADAPTER, 1/4" NPT OVERFLOW TUBE, .50 ID x 6" LG. BARBED TEE, 1/4-18 NPT TO ½ " JUMPER WIRE, 20GA. X 1.50" LONG MOLEX PLUG BLACK WIRES 18GA. X 18" LONG SOLENOID V AL VE, 24/60 V AC 2 63 0 A irp o rt Ro a d K in s t on , N C 28 5 04 P H : 2 52 .
Smart Digital Humidistat Installation and Owner's Manual The 072000 is a digital humidifier control that can automatically adjust the indoor humidity set point as the outside air t em p e r a tu r e c h an g e s . T h is i n t e ll i g e n t control will maintain accurate humidity levels and a more comfortable indoor environment.
Z100 A SSEMBL Y INST ALL A TION INSTRUCTIONS & OWNER'S MANUAL Z100 REPL ACEMENT INSTRUCTIONS ELECTRONIC STEAM POWER HUMIDIFIERS MODEL # S2000 AND S2020 APPLICA TION NOTE AN 131 C o p yr igh t © 2 0 1 1 Fi e ld Co n trols A l l Ri g h t s Rese rved .
APPLICA TION NOTE P ART # 2009 AN 151 SC100 - P AR T # 2009 DECORA TIVE COVER S2000/S2020 STEAM HUMIDIFIER SC100 Installation Instructions P/ N 09 0 3 76 A0 15 1 R EV.
16 Model Number:____________________Serial Number:____________________Date Code:_____________________ Date Purchased:_________________________________________________________________________________ D.
Een belangrijk punt na aankoop van elk apparaat Field Controls S2000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Field Controls S2000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Field Controls S2000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Field Controls S2000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Field Controls S2000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Field Controls S2000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Field Controls S2000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Field Controls S2000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.