1 INST ALLA TION AND OWNER’S MANUAL As of date of ma nufactur e, meets all ANSI/UL 3 25 Safety Requir ement s for Vehicular gate operators HDSWG 1000 Heavy Duty Commercial V ehicular Swing Gate Oper.
2 Pre-In sta llat ion No tes ............................................................................ 3 Sect ion A : In s talla tion N otes ................................................................ 4 Sect ion B : P rep arin g t he Site ....
3 W A RNING HIGH VOL T A GE ONLY A QUALIFIED TECHNICIAN SHOULD SERVICE THIS G A TE OPERATOR PERIODICA LLY TEST SENSITIVITY OF OVERLOA D *** READ MANUA L *** DA TES OPERATOR DA TE TE ST ED DA TE TE ST .
4 T O REDUCE THE RISK OF SEVERE INJUR Y OR DE A TH: RE AD A N D FOL LOW A LL INST A LL A T ION INST RUCTION S A ND GA TE SYSTEM DESIGN P A R AMETERS! WARNING! GAT E SYST EM D ESIG N AN D INSTA LLA T ION SAFETY CHECK LIST: • DO NOT locate an y device (ke y switch, s witch, ke y pad, card reader, etc.
5 • Check the operator m anufacturer’s specif ication to ens ure that the ope rator is proper for the cy cles pe r ho ur, s ize a nd ty pe of gate. • USE EXTREME CAUTION WHEN WORKING NEAR THE BELTS AND PULLEYS when th e operator cover is removed.
6 The s tandard H DSWG 1000 is desig ned to oper ate a single leaf gate . The cont rol box an d mechanic al unit s are separate devi ces. It is necessa ry to find a suitable loca tion to moun t the contr o l box, i.e ., post or wall. Se parate low voltag e and high v oltage c onduits w ill be run between th e contro l box and mech anical un it.
7 For saw -cut installations , obse rve the me thods rec omm ended in Figure 7, above. T he saw-cut m ust be to a depth of 1.5", c lean a nd with no sharp c orners. A fter placing the w ires, it is essential that the wires be h eld tigh tly in place b y a foa m backing p rior to pouring t he sealant.
8 electrical servi ce depen ds on the dist ance of the operato r from the breaker pan el. Refer to Table 1 to d etermine the correct wire size. The NOMINAL col umn is the ideal distance fro m the breaker p anel to the op erator for a given wir e size and voltage.
9 Mechanical Unit Electrical Unit Wood Pallet with 4 lag bolts Instruc tion Ki t Instr uction Manual War ni n g si gns Swing A rm Kit Swing Arm Crank Arm Crank Arm Extension Swi ng Gate Fitti n gs Swi.
10 PLACING THE HDSWG 1000 MECHA NIC A L UNIT Remove the rain seal from the shaft of the HDSWG 10 00. SAV E IT! The rain seal w ill be used la ter. Next, re move the cove r from the HDSWG 1000 MECHAN ICAL UNI T by remov ing the 1/4 inch diameter bol ts on each side of the Uni t and set it aside.
11 INSTALLING THE HDSWG 1000 CONTROL BOX The H DSWG 1000 CONT ROL BOX may be mounte d rem otely from the MECHA NICAL UNIT. Four m ounting holes are provided a t the ba ck of the CONTROL BOX. T hese should be used to m ount the CONTROL BOX to a solid, f lat surfa ce.
12 CONNECTING THE AC WIRING 115 VOLT INSTA LLATION S: Starti ng at the HDSW G 1000 4 x 4 h andy box p roceed as fol lows: 1. The BLA CK wire attaches to the 115 V AC HOT wire, normally black. 2. The W HITE w ire attaches t o the 115 VAC NEUTRAL wire, norma lly w hite.
13 Figure 12: Left/Right Hand Installati on Limit & Motor Wiring Diagram C: INST A LLING THE OPER A TOR.
14 Figure 13: Bi-Parting Install ation Limit & Motor Wiring Diagram C: INST A LLING THE OPER A TOR.
15 The L imit Sw itch contac ts of th e tw o Bi-Parting u nits nee d to be wired in se ries. Both lim it switch conta cts m ust be closed be fore a connectio n is m ade to the limit sw itch input at the Control B ox to stop the mot ors at the Open or Closed posit ion.
16 THREE TERMINAL RECEIVERS If a three terminal receiver is to be used, the #1 terminal of the receiver is normally COMMON to both the auxiliary transformer (powe r input) and the ra dio re la y. Most ra dio manuf act urers labe l this termina l as 24 VAC.
17 WIRING A KEYPAD, CA RD READER OR TELEPHONE ENTRY SYSTEM Thes e dev ices a ctiva te the H DSWG 1000 by a relay c ontact closur e within t he device. Typical ly, two wires or terminals are pro vided by the devi ce to operate the gat e. Follow th e manufacturers inst ructions on locat ing these conn ection s.
18 # NAME DESCRIPTION 1 LOCK SOLENO ID 2 LOCK SOLENO ID 3 COMMON One of (2) boar d commons provided on t he terminal strip 4 CLOSE LIMIT SWITCH Used to co nfigure r ight hand/l eft hand oper ation — See P. 1 3 , Fig 11, Limit S witch W ires. NOTE: En sure that wire to terminal 4 is same col or as wire to ter minal 14.
19 SET TIN G TH E LI MI T SW I TCHES RIGHT -HAN DED OP ERAT ION With the cover re mov ed from the HDSWG 1000 MECHANICA L UNIT, and th e arm conn ected to the gate as well as to the HDSWG 1000 Opera tor, posit ion the ga te at its fully closed positio n.
20 TIMER TO CLOSE SETTING The T imer to Close is co ntrolled by the switch in position #3. If Sw itch #3 is set OFF, the Tim e r to Close functio n w ill operate a fter the ga te has opene d. If Switch #3 is set ON, the Time r to Close func tion w ill be disable d.
21 Triac Lig ht stays ON. Lock light is ON. 6. Term inal #6, Stop,: Both Ope n and C lose T riac lights ar e momentaril y ON, then bo th Open and Clo se Triac lights go OUT. The Loc k ligh t go es OU T. Th e st op ligh t i s ON as long as the wire is he ld on the te rmina l and the st op light goe s OUT when the wire is re moved.
22 MAXIMUM RUN TIMER The H DSWG 1000 is equi pped with a Ma xim um Run T imer that is Factory set to turn the HD SWG 1000 OFF if a Limit Sw itch command is not received within 45 S econds after a Comman d to Open or Close is g iven.
23 You are now r eady to install and conne ct the anc illary equipme nt. INSTALLATION STEPS DETAILED IN SECTIONS A, B, C AND D MUST BE COM PLETE BEFORE PROCEEDING. 1. Vehicle Det ectors: If a Vehicl e Detect or (Rev ersing L oop) is to be a part of this installation, start with this first.
24 To the Owner/End User of A llstar’s HDSWG 1000: Thank you f or choosi ng an Allsta r produc t. W e ar e conf ident you wil l have many years of use and satis faction w ith your ga te opera tor.
25 AVOI D E NT RAPM EN T: St ay away f rom the path of the g at e and all moving part s (gate arms, etc.) at all tim es. Keep clear of the pinch points ide ntif ied be low.. Install g uards or othe r s afe ty fe atures to prevent access to pinch point areas.
26 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 106359 Figure 24: HDSWG 1000 Mechanical Unit Exploded View MECHANIC A L UNIT EXPLODED VIEW.
27 ITEM # PART # DESCRIPTION 1 10291 RAIN SEAL RUBBER RING 2 104442 RAINSEAL PLATE 3 10279 OPERATOR COVER 4 10221 ROLLER CHAIN 5 104452 OUTPUT SHAFT 6 10216 SPROCKET , 1-1/4 SHAFT 7 104479 ARM ST OP P.
28 c.p. A l lstar Corporation Downingtown, P A 19335 This Gate Oper ator is built in the USA and complies with a ll requireme nts of Underwriters' Laboratories Standard UL-325.
Een belangrijk punt na aankoop van elk apparaat Allstar Products Group HDSWG 1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Allstar Products Group HDSWG 1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Allstar Products Group HDSWG 1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Allstar Products Group HDSWG 1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Allstar Products Group HDSWG 1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Allstar Products Group HDSWG 1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Allstar Products Group HDSWG 1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Allstar Products Group HDSWG 1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.