P RODUCT S PECIFICA TIONS SS-PCB50 www .goodmanmfg.com 6/06 Supersedes 12/05 S ELF -C ONT AINED P ACKAGE A IR C ONDITIONER The PCB Commercial 50 Hz self-contained packaged air conditioner is designed for ground-level or rooftop application. PCB C OMMERCIAL S ERIES 50 Hz C OOLING C AP ACITY : 90,000 TO 180,000 BTU/ H 7½, 10, AND 15 T ON [26.
2 SS-PCB50 P RODUCT S PECIFICA TIONS S PECIFICA TIONS PCB090-5 PCB120-5 PCB180-5 T otal Cooling - BTU/h (kW) 88,400 (25.9) 118,600 (34.8) 172,000 (50.4) Sensible Cooling - BTU/h¹ (kW) 67,100 (19.7) 89,200 (26.1) 131,000 (38.4) EER² 8.9 9.7 8.5 Indoor Blower (Qty .
SS-PCB50 3 P RODUCT S PECIFICA TIONS UNIT SIZE A - HEIGHT B - SUPPL Y AIR C - RETURN AIR 090 36” (914 mm) 12½” (318 mm) 179/16” (446 mm) 120,180 52” (1321 mm) 20¼” (514 mm) 2513/16” (656 mm) D IMENSIONS All dimensions in inches and millimeters.
4 SS-PCB50 P RODUCT S PECIFICA TIONS E LECTRICAL C ONNECTIONS Main power entrance location (with electric heat installed) Control wiring entrance location Main power entrance location (without electric heat installed) Note: Single-point wiring is available at location #1 when heat kit is installed.
SS-PCB50 5 P RODUCT S PECIFICA TIONS CFM EXTERNAL ST A TIC PRESSURE (INCHES W .C.) SEE NOTE (3) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2600 669 0.44 816 0.59 916 0.75 1004 0.92 1084 1.09 1157 1.
6 SS-PCB50 P RODUCT S PECIFICA TIONS Motor Sheave - Adjustable Factory Setting F an Sheave - Fixed T wo T urns Opens Motor Sheave T urns Open 0 1 2 3 4 5 F an RPM 3.0 HP Motor 1242 1186 1129 1073 1016 960 Note: Allow ±5% variation in blower RPM due to pulley manufacturing tolerances.
SS-PCB50 7 P RODUCT S PECIFICA TIONS Motor Sheave - Adjustable Factory Setting F an Sheave - Fixed 2 T urns Opens Motor Sheave T urns Open 012345 F an RPM 5.0 HP Motor 1400 1446 1273 1209 1146 1082 Note: Allow ±5% variation in blower RPM due to pulley manufacturing tolerances.
8 SS-PCB50 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 75°F 85°F 95°F 105°F 115°F SCFM WB To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw 2550 72 111.
SS-PCB50 9 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 23.9°C 29.4°C 35.0°C 40.6°C 46.1°C L/S WB T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw T otal Cap. Sens Cap. Kw 2246 22.
10 SS-PCB50 P RODUCT S PECIFICA TIONS INDOOR AIR CONDENSER AIR TEMPERA TURE 75°F 85°F 95°F 105°F 115°F SCFM WB To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw To t a l Kbtuh Sens Kbtuh Kw 4760 72 219.
SS-PCB50 11 P RODUCT S PECIFICA TIONS F ACT OR Y S UPPLIED A CCESSORIES T HERMOST A T (CHT90-120) T wo-stage cool and two-stage heat thermostat with subbase, Manual changeover , Fan ON or AUT O. Note: A variety of thermostat con fi gurations can be used on this equipment based on the application needs.
12 SS-PCB50 P RODUCT S PECIFICA TIONS Q UALITY M AKES THE D IFFERENCE ! All of our systems are designed and manufactured with the same high-quality standards, regardless of size or ef fi ciency . W e have designed these units to signi fi cantly reduce the most frequent causes of product failure.
Een belangrijk punt na aankoop van elk apparaat Franklin Self-Contained Package Air Conditioner (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Franklin Self-Contained Package Air Conditioner heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Franklin Self-Contained Package Air Conditioner vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Franklin Self-Contained Package Air Conditioner leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Franklin Self-Contained Package Air Conditioner krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Franklin Self-Contained Package Air Conditioner bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Franklin Self-Contained Package Air Conditioner kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Franklin Self-Contained Package Air Conditioner . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.