KEEP THIS OPERA TION MANUAL FOR FUTURE REFERENCE OPERA TING MANU AL P/N9359944010 COOLING MODEL ROOM AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE COOLING MODEL Indoor Unit ABU 22 Outdoor Uni.
En-2 CONTENTS SAFETY PRECAUTIONS ....................................... 2 FEA TURES AND FUNCTIONS .............................. 3 NAME OF P AR TS ................................................... 4 PREP ARA TION ...................................
En-3 FEA TURES AND FUNCTIONS AUTOMA TIC OPERA TION ● COOLING MODEL Merely press the ST AR T/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
En-4 Instructions relating to heating(*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). NAME OF P AR TS Fig. 5 SLEEP TIMER SET TIME SET TEMP MASTER CONTROL FAN CONTROL START STOP .
En-5 Fig. 5 Remote Control Unit F SLEEP Button G MASTER CONTROL Button H SET TEMP ./SET TIME Buttons ( ) I Signal T ransmitter J TIMER Button K F AN CONTROL Button L ST ART/STOP Button M Battery compartment lid Inside of the battery compartment lid (Fig.
En-6 PREP ARA TION T urn on the Power T urn on the circuit breaker . Load Batteries (R03/LR03/AAA × 4) 1 Slide the battery compartment lid to open it. 2 Insert batteries. Be sure to align the battery polarities ( ) correctly . 3 Close the battery compartment lid.
En-7 Instructions relating to heating (*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). OPERA TION T o Select Mode Operation 1 Press the ST ART/STOP button. The indoor unit’ s OPERA TION indicator light (red) will be on. The air conditioner will start operating.
En-8 OPERA TION Setting temperature Thermostat control Dry Operation Cooling Operation Instructions relating to heating (*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). * During Heating mode: Set the thermostat to a temperature set- ting that is higher than the current room temperature.
En-9 TIMER OPERA TION Instructions relating to heating (*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). Before using the timer function, be sure that the remote control unit is set to the current time (See page 6).
En-10 TIMER OPERA TION About the PROGRAM timer ● The PROGRAM timer allows you to integrate OFF timer and ON timer operations in a single sequence. The se- quence can involve one transition from OFF timer to ON timer , or from ON timer to OFF timer , within a twenty- four hour period.
En-11 ADJUSTING THE DIRECTION OF AIR CIRCULA TION Instructions relating to heating (*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). V ertical (up-down) direction of airflow is adjusted by pressing the remote control unit’ s AIR FLOW DIRECTION VERTICAL SET button.
En-12 SWING OPERA TION Begin air conditioner operation before performing this procedure T o select V ertical airflow SWING Operation Press the AIR FLOW DIRECTION VER TICAL SWING button . The SWING indicator light (VER TICAL SWING) (orange) will turn on.
En-13 ENERGY SA VE OPERA TION Instructions relating to heating (*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). The air conditioner can be operated while keeping energy consumption costs down. How T o Use the ENERGY SA VE OPERA TION 1 Press the ST ART/STOP button (if the unit is already operating, proceed to step 2).
En-14 ● Before cleaning the air conditioner , be sure to tur n it off and tur n off the electrical breaker . ● Be sure the intake grille is installed securely . ● When removing and replacing the air filters, be sure not to touch the heat exchanger , as per- sonal injury may result.
En-15 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec- trical breaker , and consult authorized service personnel.
En-16 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEA T & COOL MODEL” (Reverse Cycle). Symptom Doesn’ t operate at all: Poor Cooling (or *Heating) performanc.
En-17 OPERA TING TIPS ● Should the power supply to the air conditioner be inter - rupted by a power failure, the air conditioner will restart automatically in the previously selected mode once the power is restored.
(800) 888-FGAI.
Een belangrijk punt na aankoop van elk apparaat Fujitsu ABU22 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Fujitsu ABU22 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Fujitsu ABU22 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Fujitsu ABU22 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Fujitsu ABU22 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Fujitsu ABU22 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Fujitsu ABU22 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Fujitsu ABU22 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.