Gebruiksaanwijzing /service van het product D2542 van de fabrikant Fujitsu
Ga naar pagina of 34
System Board D2542 for RX100 S5 Technica l Manual Edition November 2007.
Comments … Suggestions … Corrections … The User Documentation Depar tment would lik e to know y our opinion of this manual. Y our f eedback helps us optimize our documentation to suit y our individual needs. F eel free to se nd us your comments by e-mail to manuals@fujtsu-siemens.
D2542 (RX100 S5) T echnical Manual Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Import ant notes . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1 Notes on safety . . . . . . . . . . . . . . . . . . . . .
.
D2542 (RX100 S5) T echnical Manual 5 1 Intr oducti on This technical man ual describes the system board D2542, which is equipped with one Intel ® processor . Fur ther information about drivers is provided in the readme files on the hard disk, on the supplied “ServerStar t“ or “Update“ CDs.
.
D2542 (RX100 S5) T echnical Manual 7 2 Impor tant notes In this chapter you wi ll find essential info r mation regarding saf ety when working with y our ser ver . V CA UTION! With the system board installed you m ust open the system to access the system board.
8 T echnical Manual D2542 (RX100 S5) Notes on safety Important notes V ● Components can become v ery hot during operation. Ensure y ou do not touch components when making e xtensions to the system board. There is a danger of burns!. ● T ransmission l ines to peripheral devices m us t be adequately shielded.
D2542 (RX100 S5) T echnical Manual 9 Important notes Notes on safety Modules with electrostatic-sensitive compon ents Systems and components that might be damaged b y electrostatic discharge (ESD) are.
10 T echnical Man ual D2542 (RX100 S5) CE Certificate Important notes Notes about boards ● During installation/deinstallati on of the system board, observe the specific instructions described in the ser vice manual f or the ser v er.
D2542 (RX100 S5) T echnical Manual 11 Important notes Environmental Protection 2.3 En vir onmental Pr o tection En vironmentally friendly product design and development This product has been designed in accordance with standards f or ”environmen- tally friendly product design and de velopment“.
12 T echnical Man ual D2542 (RX100 S5) En vironmental Protection Important notes Returning, recycling and disposal F or details on retur ning and reuse of devices and consumables within Europe, refer .
D2542 (RX100 S5) T echnical Manual 13 3 Features 3.1 Overvie w There are two vers ions of the system board D2542 with the par t numbers S26361-D2542-A10 (SAS v ers ion) and S26361-D2542-B10 (SA T A v ersion). The two v ers ions diff er in the chipset and connectors assemblin g.
14 T echnical Man ual D2542 (RX100 S5) Overview Features External connectors – F ront side (front panel): 2x USB 2.0 port – Rear side (I/O shield): 2x USB 2.
D2542 (RX100 S5) T echnical Manual 15 Features Overview BIOS features – Phoenix system BIOS – P ower on self-test – CMOS setup parameter – Shadow RAM BIOS – Shadow video BIOS – IPMI V2.
16 T echnical Man ual D2542 (RX100 S5) Overview Features TPM ( Optio n) The system board is equipped with a TPM (T r usted Platform Module) b y the manuf acturer . This module enab les programs from third party manuf acturers to store k ey inf or mation (e.
D2542 (RX100 S5) T echnical Manual 17 Features Main memory 3.2 Main memory The four slots f or the main memor y are suitable f or unbuff ered DDR II 800 (PC2- 6400) SDRAM memory modules. The organization in tw o memor y banks, 1 and 2, permits rapid memory access with two-w ay interleaving.
18 T echnical Man ual D2542 (RX100 S5) PCI b us Features *) Already populated b y basic configuration. Install identical DIMMs in sock et 1A and 1B and identical DIMMs in soc ket 2A and 2B.
D2542 (RX100 S5) T echnical Manual 19 Features Screen resolution 3.4 Screen resolution Depending on the operating system used the s creen resolutions in the fol l owing table ref er to the screen controller on the system board.
20 T echnical Man ual D2542 (RX100 S5) T e mperature / system monitoring Features Se nsor m onitor ing A f ault in a temperature sensor is detected. Should this happen all f ans monitored by this sensor run at maximum speed, to achie ve the greatest possibl e protection of the hardware.
D2542 (RX100 S5) T echnical Manual 21 Features LEDs 3.6 LEDs Figure 4: LEDs LED s A, B, C , D , E and F are visible from outside on the rear of the server . LED A and LED B are diff erent functionalities of the same LED and are glo wing diffe- rently .
22 T echnical Man ual D2542 (RX100 S5) LEDs Features The LEDs hav e the fol lowing meaning: If the ser v er has been pow ered off (power-plugs m us t be disconnected) it is possibl e to indicate the f aulty component by pressing the indi cate CSS button.
D2542 (RX100 S5) T echnical Manual 23 Features Interfaces and conn ectors 3.7 Interfaces and connector s Figure 5: Schematic view of the system board D2542 1 = SA T A 2 connector (only f or SA T A ver.
24 T echnical Man ual D2542 (RX100 S5) Interfaces and connecto rs Features 3.7.1 External ports Figure 6: External por ts of the system board D2542 *) The Ser ver Management LAN is a direct communication interf ace between a remote system and the local iR MC.
D2542 (RX100 S5) T echnical Manual 25 Features Interfaces and conn ectors LAN connectors This system board is popula ted with two Dual Gigabit LAN controllers Broadcom 5715 and a service LAN controller . The G igabit LAN controller suppor ts the transf er rates of 10 Mbit/s, 100 Mbi t/s and 1 Gbit/s.
26 T echnical Man ual D2542 (RX100 S5) Settings with jumpers Features 3.8 Sett ings wi th ju mp ers The system board is supplied with al l jumpers set on the foll owing positi ons.
D2542 (RX100 S5) T echnical Manual 27 4 Replacing the lithium battery In order to sav e the system inf or mation permanently , a lithium batter y is installed to provide the CMOS -memor y with a current. When the charge is too low or the battery is empty , a c orresponding error message is provided.
.
D2542 (RX100 S5) T echnical Manual 29 Abbreviations The technical ter ms and ab bre viations giv en below represent only a selection o f the full list of common technica l terms and abbreviations . Not all technical terms and abbre viations listed here are valid f or the descr ibed system board.
30 T echnical Man ual D2542 (RX100 S5) Abkürzung en DDR Double Data Rate DIMM Dual In-line Memory Module DIP Dual In-line P ackage DMI Desktop Management Interf ace DMA Direct Memory Access DRAM Dyna.
D2542 (RX100 S5) T echnical Manual 31 Abkürzungen HPC Hot-plug Controller ICE In Circuit Emulation IDE Integrated (int elligent) Dr ive El ec tronics IME Integrated Mirror Enhanced IOOP Intelligent O.
32 T echnical Man ual D2542 (RX100 S5) Abkürzung en NVRAM Non V olatile RAM ODD Optica l Di sc Dr ive OEM Original Equipment Manuf ac turer OHCI Open Host Controller Interf ace OS Operating System PC.
D2542 (RX100 S5) T echnical Manual 33 Abkürzungen RAM Random Access Memory RSB Remote Service Board RST ReSeT RT C Real Time Clock SAS Serial Attached SCSI SA T A Serial A T A SCSI Small Computer Sy .
34 T echnical Man ual D2542 (RX100 S5) Abkürzung en TPM T rusted Platform Module UHCI Unified Host Controller Interf ac e USB Universa l Ser ia l Bu s VG A Video Graphics A dapter VRD V oltage Regula.
Een belangrijk punt na aankoop van elk apparaat Fujitsu D2542 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Fujitsu D2542 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Fujitsu D2542 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Fujitsu D2542 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Fujitsu D2542 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Fujitsu D2542 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Fujitsu D2542 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Fujitsu D2542 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.