Gebruiksaanwijzing /service van het product 6K32FR van de fabrikant GarrettCom
Ga naar pagina of 75
www Garre t t C om c om .. www Garre t t C om c om .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) i www Garre t t C om c om .. Magnum 6K32F, 6K32FR, 6K32FC & 6K32FRC Managed Switch Hardw are Installation and User Guide Part #: 84-00103Z (Rev.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) ii www Garre t t C om c om .. Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823Westinghouse Dr.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) iii www Garre t t C om c om .. TABLE OF CONTEN TS .......................................................................... Page 1.0 SPECIFICATIONS ...........................
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) iv www Garre t t C om c om .. 4.4 Flow-control, IEEE 802.3x standard .................................................. 46 5.0 6K32F SERIES MANAGED SWITCH PORT MODULES.........
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) www Garr et t C om c om .. The Magnum Line INDUSTRIAL NETWORKING PRODUCTS "DESIGNED AND M ANUFACTURED IN THE US A" OVERVIEW GarrettCom, Inc.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 1 www Garr e t t C om com .. 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Filtering / Forwarding Rate: Ethernet:14,880 pps Fast Ethernet: 148,800 pps Gigabit Ethernet: 1,488,000 pps Switching Processing Ty pe: Store and Forward with IEEE 802.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2 www Garr e t t C om com .. Maximum Standard Gigabit Eth ernet Segment Lengths: 1000BASE-T (CAT5E or higher is recommended) - 100 m 1000BASE-SX, full-duplex, multi-mode(62.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3 www Garr e t t C om com .. Fuse Required – 3 Amps 125VDC and 100VDC Input Voltage : 88 to 300VDC Fuse Required – 1 Amp Std.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 4 www Garr e t t C om com .. 1.2 Ordering Information Magnum Managed Switch MODEL DESCRIPTION Magnum 6K32F or 6K32FR (Reverse.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 5 www Garr e t t C om com .. 6KP8-MTRJ SFF Fiber module, w/eight 100M b mm FX MT-RJ connectors 6KP8-MLC SFF Fiber module, w/e.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 6 www Garr e t t C om com .. GBIC-TP GBIC transceiver module for use in GBPM-xOTX.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 7 www Garr e t t C om com .. 6K32F Series PoE Modules with 48VDC Pass-Through Configuration options: All module slots of 6K32.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 8 www Garr e t t C om com .. 6K32F Series PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Swit c hes having A.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 9 www Garr e t t C om com .. 2.0 Introduction 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2.2 Product Description – Magnum 6K32FC / FRC (Convection cooled - No-fans) Managed Switch All of the Magnum 6K32F Series of Ethernet Switches comply with IEC61850 and IEEE1613 Utility Automation and other industry standards.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 11 www Garr e t t C om com .. switching services for both “smooth” streami ng and “bursty” data traffic. For redundant LANs it offers S-ring, RS-Ring, Link-Loss-Learn, STP and RSTP.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) AC, and –48VDC power input options are de signed for Telco environments, while the 24VDC is designed for Industrial/Contro l Room applications. The 125 & 250VDC versions are for power s ub stations applications.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) designed to meet the future demand of Ethern et requirements with cost-effective s ecure solutions.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2.2.3a PoE(Power Inside), model PI 6KP8-45RJ (MDIX), 8-port 10/100Mb The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices, per the IEEE802.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) modules. Please check the orde ring information Sec.1.2 for all the various P6K PoE modules option. The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2.2.5 Four-Port 10 Mb mm Fiber ST Modules The 4port @10Mb ST fiber modules be have the same as the 8@100Mb ST fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present, ports 3, 4, 7, 8 are not present.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 18 www Garr e t t C om com .. The 1000Mb Gigabit fiber-port modul es on the Magnum 6K32F Series switches are normally set (factory default) to operate at AUTO mode for best fiber distance and performance.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 19 www Garr e t t C om com .. When the Magnum 6K32F Series Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets ou the devices sending packets to cause “flow c ontrol”.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 20 www Garr e t t C om com .. 2.3 Features and Benefits Managed switching for high performan ce Ethernet LANs Magnum 6K32.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 21 www Garr e t t C om com .. client for IP configuring, Radius X, TACACS+ etc. MDI-MDIX Auto-negotiating on RJ-45 ports for con venient cascading usin g straight RJ-45 cable.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The modularity of the 6K32F Series Managed Switch makes it an attractive choice for use in applications with LAN conn ections to an organization’s multiple site offices.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 23 www Garr e t t C om com .. managed to provide easy, detectable, unint errupted support through a viewable SNMP onitor. ure other security features to provide a ser e the bandwidth for high speed to upport the peak traffic and minimize congestion.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 6K32F Series in a Redundant application Example 4: In a “ (video+data)” application where a network being designed to cat.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K32F Series to meet the fastest growing applica tion of video monitoring or video surveillance demand of industry and provide an economical and effective solution to meet that expectation.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 26 www Garr e t t C om com .. 3.0 Installation Before installing the equipment, it is necessary to take the following precautions: 1.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 27 www Garr e t t C om com .. 3.2 Connecting Ethernet Media The Magnum 6K32F Series Switc hes are specifically designed to support all standard Ethernet media types within a single Switch unit.
Magn m 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) u 28 www Garr e t t C om com .. 4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 29 www Garr e t t C om com .. shielded, either unshielded or shielded cables and wiring may be used.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.2.6 Gigabit SFP (Small Form-factor Pluggable ) Optical Transceivers The small form-factor pluggable (SFP) is a co mpact optical transceiver used in optical communications for both telecommunication a nd data communications applications.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The various SFPs transceivers supported by GarrettCom 6KQs D slot are- Module Model# Gigabit Gb Modules, fixed ports--SFP (Small Form Factor) 6KP2-2GSFP 2 SFP 6KP2-1GSFP1CU 1SFP 31 www Garr e t t C om com .
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 32 www Garr e t t C om com .. and the “Cable Loss” for 9/125 (Single-mode) i s 0.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.3 Table-Top or Shelf Mounting The Magnum 6K32F Series Managed Switc hes can be easily mounted on a table-top or any suitable horizontal surface. They have four rubber feet to provide stability without scratching finished surfaces.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a package, along with the necessary screws for attaching the brackets to the sides of the Magnum Switch unit.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 35 www Garr e t t C om com .. The 32-port units will consume over 30 watts of power typically.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.5 6K32F Series Port Module (6KPM) Installation The Magnum 6K32F Series Switches are received from the factory with the customers required 6KPM modules installed. There may be situati ons where 6KPM cards need to be added or replaced.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Step 2. Remove Chassis Cover The Magnum 6K32F chassis are combined with top, bottom and module panel parts and assembled together with the help of 34 Philips-head screws. First Remove the side panel (2 screws located on the right side of chassis).
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Looking down into the Magnum 6K32F Series un it, notice that there are individual PM installation spaces and female latch (white) c onnectors provided on the far right side of the main board along with four stand-off’s for 6KPM card position.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Step 3. The figure here illustrates the basic lay out of an individual PM card. 6KPM card fits into the space provided on the main board over the grand-daughter Bd. a nd the ( as shown in below fig.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) NOTE: . When leaving 6KPM slots empty, always use a face plate (Magnum 6KM- BLNK) to cover the slot opening in the fr ont panel. This will ma intain proper cooling air flow, safety, and operation as requir ed by FCC, CE, and other regulations.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Step 2. Remove retaining screws placed on top for the 6KPM On the top of the daughter module there are seven retaining screws for each 6KPM card. These screws are used to secure a 6KPM card in pos ition (see Figure 3.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.6 Connecting the Console Terminal to Magnum 6K32F Series Management) ( Use a DB-9 “null modem” cable to connect the Magnum 6K32F Series Console Port (the RS-232 port on the 6K32F Switch) to the your PC, so that your PC becomes the 6K32F ’s Console Terminal.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 43 www Garr e t t C om com .. connect directly to the switch using a straight through cable. Note : For using Console port to configure the managed switch, a serial (Null-modem) female to female cable is required to communicate properly.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 44 www Garr e t t C om com .. 4.0 OPERATION This chapter describes the functions and operation of the Magnum 6K32F Series Switch. 4.1 Switching Functionality A Magnum 6K32F Series provides switche d connectivity at Ethernet wire- speed among all of its ports .
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 45 www Garr e t t C om com .. 4.2 Status LEDs For all Magnum 6K32F Series models : PWR: Power LED, ON when external power is applied to the unit. LK: Steady ON, Link status for 10 Mbps and 100Mbps operation.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) When Magnum 6K32F Series RJ-45 coppe r ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 47 www Garr e t t C om com .. blocking) on Full-Duplex ports, which provide s for a “PAUSE” packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) modular slot. Since the Magnum 6K32F Series Switches have dual-speed capability for copper ports, the 6 or 8-por t interfaces are designed to support all standard Ethernet media types at 10 or 100Mps speed.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) connector functions as a fiber optic tr ansceiver to support 10BASE-FX network segments.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb ST module a llows it to connect the 100Mb demand of the Switch devices.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 51 www Garr e t t C om com .. functions in one module of the 6K32F Se ries Switch supporting four Copper and two single-m s -mode and cable lengths can be as much as a The e 6KP6-RJMSC, the label Sgl.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) indicating proper connectivity with the re mote device when lit, and a FDX/HDX L indicating full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed for the co ED pper port, wh ich is 10Mbps when the LED is ON and 10 Mb when the LED is OFF.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) the same as the ST and SC-types. It has the same LEDs per port indicating port activity ACT), Link (LK), and FDX or HDX operation ( 5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factor The Magnum 6KP (Small Form Factor) MTRJ type ports.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off).
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connec tivity wi.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 56 www Garr e t t C om com .. informati the roperly to an 803.af compliant PD device on that port.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) traffic is not affected by PoE. LINK and ACTIVITY LEDS are combined hat is marked as LINK/ACT, as shown in the diagram PoE ED on the PoE modules into one LED . t L s Summary For P oE devices, each RJ-45 PoE port supports only 802.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 5.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor The Magnum 6KP8- 45SLC eight port Module is a combo module with copper and fiber (Small Form Factor) LC type fiber ports.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 5.2.12a GBPM-2OTX (Two Gigabit option) The Magnum 6K32-Series offered a wide selection of Gigabit speed with multiple choice of copper or Fiber or mix for the modular slot via GBPM-2OTX (2 x Giga module).
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports) as shown below in the above figure.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 61 www Garr e t t C om com .. 6.1 Befo re Ca lling for Assistance 1. If difficulty is encountered when insta lling or operating the unit, refer back to the Installation Section of the applicable chapter of this manual.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 62 www Garr e t t C om com .. 2. An accurate list of GarrettCom product model(s) involved, with serial number(s). Include the date(s) that you purchased the products from your supplier.
Magnum 6K32F/FR/FC/FRC Managed Switch In tallat s ion and User Guide (05/08) 63 www Garr e t t C om com .. 6.4 Shipping and Packaging Information Should you need to ship the unit b ack to GarrettCom, please follow these instructions: 1. Package the unit carefully.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) APPENDIX B : Internal DC Power Supply Options B1.0 SPECIFICATIONS FOR MAG NUM 6K32F SERIES SWITCHES, DC POWER Power Supply (I.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) B3.0 APPLICATIONS FOR DC POWERED SWITCHES Magnum 6K32F Series Fiber Switches ar e easily installed in a variety of applications where -48VDC, 24VDC and 125VDC power is used as the primary power source.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 66 www Garr e t t C om com .. Note: The GND should be hooked up first. The 6K32F unit has a floating ground, so the user may elect to Grou nd either + or - ter minal to suit the customer ’s use.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) APPENDIX C: Internal DC Dual-Source Power Option C1.0 SPECIFICATIONS - FOR MAG NUM 6K32F SERIES FIBER SWITCH Power Supply (In.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION The Dual-Source DC power option is designed using diodes inside of the chassis on each DC power input line.
Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 69 www Garr e t t C om com .. Note: The GND should be hooked up first. The 6K32F Series units have a floating ground, so th e user may elect to Ground eith er + or - terminal to suit th e customer’s use.
Een belangrijk punt na aankoop van elk apparaat GarrettCom 6K32FR (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GarrettCom 6K32FR heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GarrettCom 6K32FR vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GarrettCom 6K32FR leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GarrettCom 6K32FR krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GarrettCom 6K32FR bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GarrettCom 6K32FR kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GarrettCom 6K32FR . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.