EE.UU./Canadá – 230 V 50/60 Hz Número de Ensamblaje 7707010
78 to 101 103 to 126 128 to 151



The safety of you and others is very important to GBC. Important safety mes- sages and information are contained within this manual as well as on the machine itself. Please be certain to carefully read and understand all of these before operating the machine.
The safety alert symbol precedes each safety message in this Operating Instruction Manual. This symbol indicates a potential personal safety hazard that could hurt you or others, as well as cause product or property damage.
The following pictorial is found on the Quantum P70iX:




The following symbols appear on this product, and their meaning is as follows:
I Means the electrical power is “ON”.
O Means the electrical power is “OFF”.


(THE FOLLOWING NOTE APPLIES ONLY TO EUROPEAN UNITS)
The cordset consist of three parts; the attachment plug, cordage and appliance inlet. Each of these components must have European regulatory approvals for safety.
The following minimum electrical ratings for the specific cordset are published for safety purposes. DO NOT USE CORDSETS THAT DO NOT MEET THE FOLLOWING MINIMUM ELECTRICAL REQUIREMENTS.
PLUG: 3 amperes, 250 volts, 50/60 Hz, Class 1, 3 conductor, European safety approved.
CORDAGE: Type H05VV-F3G0.75, Harmonized ( < HAR> ). The “< >” sym- bols indicate cordage approved to appropriate European standard (NOTE: “HAR” may be substituted for approval mark of European safety agency, which approved the cordage. An example would be “ < VDE > “).
APPLIANCE CONNECTOR: 3 ampere, 250 volts, 50/60 Hz, European safety approved, Type IEC 320. The cordset shall not exceed 3 meters in length. A cordset with component electrical ratings greater than the minimum specified electrical ratings may be substituted.

(THE FOLLOWING NOTE APPLIES ONLY TO THE U.S. UNITS.)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Operator Manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
Cet appareil numerique dela classe A est conforme a la norme NMB-003 du Canada.
SERVICE AND EQUIPMENT MAINTENANCE AGREEMENT By purchasing the P70iX you have invested in a highly capable punching machine that will give you years of reliable service. To help protect this invest- ment be certain to take advantage of the GBC Equipment Maintenance Agreement (EMA). The EMA provides your P70iX with proper ongoing mainte- nance and care, helping to ensure the years of quality performance and long life built into the machine. Without an EMA, a charge for parts and labor would result from every normal maintenance or repair service call. An EMA for your P70iX eliminates this possibility by providing you with a low, fixed annual cost for protecting your valuable machine investment. For full details about purchasing an EMA, consult with your GBC Sales Representative or contact: General Binding Corporation 500 Bond Street Lincolnshire, IL 60069 Or Call: 1-800-790-7787 A GBC Authorized Technician must perform all service and maintenance unless it is operator maintenance in accordance with the P70iX Automatic Punch User Guide. Use of the P70iX Automatic Punch in any manner not in accordance with the GBC P70iX User Guide is not recommended and may void your warranty or maintenance contract Trained operators and regular operator maintenance of the P70iX A can opti- mize performance and minimize service calls.

The Quantum P70iX is designed to meet the unique requirements of the digital print marketplace. It is designed to support all commonly required punching pat- terns, including three-hole, comb, VeloBind, Twin-Loop wire, and Color Coil. Custom die patterns are also available. This new system is designed to deliver the quick changeover requirements of the short-run digital printer.
Virtually all set-ups are quickly and easily accomplished from the digital print display panel, overcoming a major time-consuming aspect of traditional produc- tion punches. Die changes can be accomplished in a short time without tools. The system is pre-programmed with all common paper sizes, and can store 20 custom jobs.
The P70iX is designed to handle a wide range of media. It can handle sheet sizes from 5 1/2” x 5 1/2” to 9” x 12”, including mixed paper-weights and cover stocks. Another key feature is the system’s ability to process intermixed index tabs without any special adjustments.
The P70iX incorporates GBC’s new “stack processing” technology, which is designed to reduce operator labor cost. This new architecture allows the system to process a 14” stack (3,500 sheets 20# bond) without operator attendance. The P70iX offers a maximum throughput speed of 60,000 sheets per hour.
The Quantum P70iX is GBC’s revolutionary new, near-line, high-speed Digital Production Punch. It sets up in minutes and keeps up, side-by-side, with banks of today’s fastest digital print engines.
These instructions have been prepared to acquaint you with the Quantum P70iX punch and it’s operation. Please read them carefully. Keep these operating instructions for future reference.
The Quantum P70iX punch must be installed by a qualified GBC Technician. Your Technician will ensure that the system is properly leveled and ready to run.

External factors can affect performance of your P70iX. These factors include customer requirements for hole quality, throughput materials (paper/transparen- cies/covers), toner coverage on the printed page, and environmental factors. Static in the paper can result in poor performance. If your P70iX runs a fresh ream of clean white paper but has trouble with your printed job, it may be due to static. The following tips might help you to correct this problem.
Suggestions for static: If you’re P70iX Automatic Punch is having trouble running certain jobs, it may be due to excessive static build-up in the paper. Here are some suggestions that may help to minimize the static effect.

To ensure your satisfaction, please take a moment to understand the following application limitations.

The Quantum P70iX is capable of handling and punching some types of clear cover stock materials. In fact, every Quantum P70iX is tested with clear covers before it leaves the factory. The following guidelines will help you to understand the capabilities of the Quantum P70iX system. In cases where your particular clear cover stock is not suitable to run through the Quantum P70iX, you may want to try separating the clear covers from the book contents and punching the clear covers using a GBC Magnapunch heavy duty table top punch.




The GBC Quantum P70iX Automatic Punch is capable of punching a variety of hole patterns commonly used in binding today, by simply changing the Die Set. Die sets can be changed in seconds without tools.
A significant feature of the Quantum P70iX is that it uses GBC Magnapunch Die Sets. If you include a Magnapunch in your paper punch work station, you will enjoy the flexability and versility of diesets that can be used in either punch platform. Some jobs or parts of jobs may be better suited for the table top paper punch. Please note: The PB Plastic Bind with multiple adjust depth of punch Magnapunch Die Set is not suitable for use in the automatic paper handling system utilized by the Quantum.
The Die Sets currently available are listed below. Your GBC Sales Representative can provide you with price and availability, or contact the GBC Call Center at 1-800-723- 4000. For more information, visit GBC’s website at www.gbcconnect.com
Each punching style listed below requires a separate die set for the Quantum P70iX.
Quantum P70iX Automatic Punch - Die Sets Product Code PB Plastic Bind – Deepest Fixed Back Gauge, .187” 7707230
PB Plastic Bind – Middle Fixed Back Gauge, .141” 7707220 PB Plastic Bind – Shallow Fixed Back Gauge, .094” 7707210
W3 Twin Loop Wire - 3:1 Round 7708350 W3 Twin Loop Wire - 3:1 Square 7708360 W2 Twin Loop Wire - 2:1 Rectangular 7708330
W2 Twin Loop Wire - 2:1 Round 7708320 C4 Color Coil – 4:1 Oval .2475 7707290 C4 Color Coil – 4:1 Round .2475 Pitch 7708300
C4 Color Coil - 4:1 Round .250 Pitch 7708310 Color Coil Heavy Duty C4 Oval Quantum Dieset 7707300
VB VeloBind 11 inch 7708340 Ring Binder 2-4 Standard 5/16” Diameter Hole (Europe) 7708390
Ring Binder 3-5-7 5/16” Diameter Hole (U.S.) 7708380
GBC offers a full suite of binding equipment and supplies to meet your binding needs. In addition Custom Die Sets are available for the Quantum P70iX. For additional information, consult with your GBC Sales Representative.

GBC Die Set Storage Cabinet #7703207 is an excellent way to store all of your interchangeable die sets for the Quantum P70iX (see figure 3). This special product securely holds three die sets, protecting them from dirt, dust, and acci- dental damage. Contact your sales representative for information on obtaining a Die Set Storage Cabinet.



The Home Screen is the starting point for operation of the Quantum P70iX. At this screen, you are able to see the job that the Quantum is ready to run. In the example above, the Quantum is setup to run the following job:
If these job settings are acceptable, you may start your job by simply:


MODE: allows you to select between Automatic or Manual. Automatic Mode means the Quantum will continue to run non-stop as long as you place paper on the Input Belts and remove the punched stack of paper from the Output Belts. The Manual Mode means the Quantum will stop before it takes the next paper stack in for processing. This mode is helpful if you want to start a new job that requires different settings such as a different Die Set, or a different paper size. PROOF: you can run a few lifts of your job and have the Quantum stop. This feature enables you to check the hole positioning and pattern to ensure the setup is the job you intended. UNLOAD: means that when pressed, the job currently inside of the Quantum will exit. This is helpful if you need to start a job over again for some reason. JOB MANAGER: will take you to the Job Manager screen where a different job can be selected or created. LANGUAGE: you may select between English, Spanish, French and German.



You have constant control of the Speed by controlling the LPM or Lifts Per Minute and the size of each Lift by adjusting the number of sheets per Lift.
Lifts Per Minute (LPM) is controlled by pressing the Left – Right arrow buttons above the numeric key pad. You will see the number change in the window. The example above reads “90 LPM”. The choices are 60, 75, 90 and 105 LPM.
Lift command (sheets punched per stroke).
The size of the lift is controlled by pressing the Up – Down arrows above the numeric key pad. The numbers roughly equal the number of sheets of 24 pound bond paper that would be picked at this setting. This feature does not actually count sheets however and you should not expect the lift to be exactly this quan- tity. The example shown is of a lift size of “7”


GO JOB 1 VIEW 13-24 EDITOR HOME 1 2 3
At the Job Manager Screen you are able to scroll between saved jobs (1 – 12) by simply pressing the right-left and/or the up/down buttons. In the example above, JOB 1 has been highlighted. To select this job and continue, simply press “GO JOB 1” button.
Other Job Manager Features:

EDITOR
USE ARROWS TO
CHANGE OTHER SIZES
ACCEPT
SETTING NO CHANGE
ESCAPE
GO BACK DATA OK STORE
SAVE
1 2 3 ESCAPE SAVE ACCEPT
To Edit an exiting job or create a new job, press the up – down arrows to select the desired setting. In the example above, the Punch Edge paper dimension has been selected and currently reads 11”.
Alternatively, the dimension can be entered directly using the numeric keypad. The machine will automatically toggle between inches and millimeters depend- ing on the size of the number entered.
The min-max range for the punch edge is 5.50” to 12.00” (139.7 mm to 304.8 mm). If at this time you entered 140 and 305, the system would automatically recognize the dimensions as 140 millimeters (mm).
Once the desired punch edge dimension appears on the display, press the “ACCEPT” button.

EDITOR
USE ARROWS TO
CHANGE OTHER SIZES
ACCEPT
SETTING NO CHANGE
ESCAPE
GO BACK DATA OK STORE
SAVE
1 2 3 ESCAPE SAVE ACCEPT
Once you have accepted the Punch Edge, the cursor will move to the Side Edge dimension.
In the example above, the Side Edge paper dimension has been selected and currently reads 8.5”.
The min-max range for the Side Edge sample shown above, is 5.50” to 9.00” (139.7 mm to 228.6 mm).
Once the desired Side Edge dimension appears on the display, press the “Accept” button.

EDITOR
USE ARROWS TO
CHANGE
GO TO NEXT
ACCEPT
SETTING NO CHANGE
ESCAPE
GO BACK DATA OK STORE
SAVE
1 2 3 ESCAPE SAVE ACCEPT
Once you have accepted the Side Edge, the cursor will move to the Punch Die type.
In the example above, the Punch Die type has been selected and currently reads PB .141. See Page 13, Diesets for the Die Sets available for the Quantum.
Once all three settings are correct, press the “SAVE” button to save the job and return to the Job Manager Screen.


Selection of a new Die Set will prompt the Die Set screen to come up. This screen will prompt you to remove the proper Punch Pin numbers for the paper size you are running. In the example shown, there are two possible pin configu- rations with this Die Set and Paper combination. The Die Set itself features a handy reference label to identify the Pin numbers. The Quantum will automati- cally center the Die Set to the paper size selected if you press buttons 2 or 4. By pressing buttons 1 or 2, the Quantum will perform all required adjustments (bind edge, side edge & center the die). You can manually fine-tune the hole centering by pressing the right-left arrows at this screen.


When the Quantum is running a job, the Graphics will provide you with informa- tion about the job that is running.
Other graphics would indicate:


If you need to stop the system immediately, press “STOP” and the Quantum P70iX will stop in mid-cycle.
To resume running your job, ensure all doors and lids are closed, then press “START”. In most cases, a normally interrupted job will clear itself and start up again . If not, you may need to clear paper from various points in the paper path.

The SLUG BIN for your Quantum P70iX is located behind the left hand access door near the bottom of the machine. The container will need to be periodically pulled out and emptied. This will avoid jamming and damage to the machine. The Quantum P70iX incorporates optical sensor technology to inform the opera- tor when the container needs to be emptied.
GBC recommends emptying the SLUG BIN whenever the EMPTY SLUG BIN appears. This indication will appear when the height of the slug pile reaches the Optical Sensor, it does not necessarly mean the container is full.
PUNCH PINS You may need to remove some of the Punch Pins for proper punching of some combinations of paper sizes and punching patterns.
SERVICE Should your Quantum P70iX require service contact your local authorized GBC service representative. There are NO user-serviceable parts inside the machine. To avoid potential per- sonal injury and/or property damage, DO NOT REMOVE THE MACHINE’S COVER.
No power, won’t punch Power cord not attached to back of machine or not properly plugged into the wall
Die Set is not fully inserted
Door or Lid is not closed
Punches too many holes Operator familiar with paper sizes referenced on the Xerox DocuTech as mm
Selectable pins have not been pulled
Go to “SETUP” and change the dimensions to “mm” from inches
When manually loading the first stack of paper onto the Feed Belts, the bottom sheets of paper catch
The surface of the belts are designed to grab the paper. You will find that it is not possible to set the paper stack on the belts and slide it into the align- ment corner. Instead, push the stack gently against the door first, then against the sheet metal right guide and then set the stack down onto the belt. Also loading a smaller stack first followed by a cou- ple of larger stacks is best
After heavy use, the machine begins to read jam, when there is no jam
A blast of air across the lens of each of the three optical sensors periodically will prevent paper dust build up from interfering with their performance.
TROUBLESHOOTING Quantum P70iX · Problem Probable Cause

Intermixed weights, flush-cut covers, and standard index tabs
(An authorized technician can separate the Quantum to fit through a
32” doorway.)
Receptacle Type 6-20R 20A, 250V
Approvals: CSA certified to CAN/CSA-C22.2 No. 60950-00, UL Std No. 60950-00, 3rd Ed.
TUV certified to EN 60950:2000
Noise Level: GBC recommends ear protection for operators of the Quantum P70iX.
Our sound test levels are as follows:
Worst Case Operation (speed 4, C4 Die Set, 20# bond, lift #9 – 12 sheets): Sound Pressure Level = LpA = 83.0 dbA Sound Pressure Impulse = LpAI = 85.2 dbA
Typical Use Operation (speed 2, PB Die Set, 20# bond, lift #9 – 12 sheets): Sound Pressure Level = LpA = 78.5 dbA Sound Pressure Impulse = LpAI = 83.5 dbA
(9.85”)
ISO 7779 Test method and microphone placement: 1.5M (59.1”) from Feeder, 1.5M (59.1”) high, 0.25M (9.85”) from vertical lead edge of Quantum at con- trol panel.
Dimensions in meters · 30° · Standing operator



Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.