Gebruiksaanwijzing /service van het product AR-6G van de fabrikant Alto-Shaam
Ga naar pagina of 34
printed i n u . s . a . Rotisserie Gas Models : AR-6G •InstallatIon •operatIon •MaIntenance W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 • 800.558.8744 USA / CANADA FAX: 262.
i Delivery .................................. 1 Unpacking ................................ 1 Safety Procedures and Precautions ............. 2 Installation Common Specifications ................... 3 Accessories ............................ 3 Dimension Drawings .
AR-6G Rotisserie Operation & Care Manual • 1 DELIVERY This Alto-Shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier.
AR-6G Rotisserie Operation & Care Manual • 2 CAUTION Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
AR-6G Rotisserie Operation & Care Manual • 3 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 3 COMMON SPECIFICATIONS ACCESSORIES AR-6G Overall height 78-1/8" 1983mm Overall wi.
AR-6G Rotisserie Operation & Care Manual • 4 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 4 TECHNICAL SPECIFICATIONS 78-7/8" (2003mm) 8-7/16" (213mm) 18-3/16" (46.
AR-6G Rotisserie Operation & Care Manual • 5 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 5 NOTE: Note dimensions required for doorways and aisles for access of the appliance and pallet to the installation site. Transport the appliance in an upright and level position only.
AR-6G Rotisserie Operation & Care Manual • 6 INSTALLATION ANSI/NSF4 AR-6G Rotisserie Operation & Care Manual • 6 SITE INSTALLATION VENTILATION REQUIREMENTS A ventilation hood is mandatory for the operation of the appliance.
AR-6G Rotisserie Operation & Care Manual • 7 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 7 POSITIONING REQUIREMENTS q In order to ensure proper ventilation, a minimum distance of at least 18" (457mm) must be kept from the side panels (left and right) of the appliance and any adjoining surfaces.
AR-6G Rotisserie Operation & Care Manual • 8 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 8 VENTILATION INSTRUCTIONS An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
AR-6G Rotisserie Operation & Care Manual • 9 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 9 ELECTRICAL An electrical wiring diagram is located under the access panel beneath the drip tray of the appliance.
AR-6G Rotisserie Operation & Care Manual • 10 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 10 AIR SUPPLY AIR SUPPLY Installation of this appliance must include a provision for an adequate flow of fresh air for gas combustion. This requirement must be observed by the installer as well as the operator.
AR-6G Rotisserie Operation & Care Manual • 11 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 11 GAS CONNECTIONS This gas appliance has been set to operate with either naturalgasorpropaneasindicatedontheidentication name plate.
AR-6G Rotisserie Operation & Care Manual • 12 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 12 GAS CONNECTIONS The installation of this appliance must be completed by aqualiedinstallerfamiliarwiththelocalcodesand regulations governing the installation of commercial gas appliances.
AR-6G Rotisserie Operation & Care Manual • 13 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 13 GAS CONNECTIONS Theminimumsizeofthegaspipingorexibleconnector is 3/4" (19mm). For long runs of gas piping, the pipe diameter must conform to the tables in the National Fuel Gas Code, ANSI/NFPA Z223.
AR-6G Rotisserie Operation & Care Manual • 14 INSTALLATION AR-6G Rotisserie Operation & Care Manual • 14 GAS EXHAUST The appliance is not to be directly connected to a chimney vent system nor directly connected to a horizontal exhaust system.
OPERATING INSTRUCTIONS AR-6G Rotisserie Operation & Care Manual • 15 AR-6G Rotisserie Operation & Care Manual • 15 BURNER LIGHTING INSTRUCTIONS Verify appliance connection to the correct gas source. Refer to the data plate located on the back of the unit.
OPERATING INSTRUCTIONS AR-6G Rotisserie Operation & Care Manual • 16 AR-6G Rotisserie Operation & Care Manual • 16 TO LIGHT THE BURNERS: 1. Select corresponding gas valve knob. Rotate the knob to the ignite position. (H=High) 2. If the burner fails to ignite after 5-seconds, turn valve to the OFF position.
OPERATING INSTRUCTIONS AR-6G Rotisserie Operation & Care Manual • 17 AR-6G Rotisserie Operation & Care Manual • 17 PLACEMENT & ADJUSTMENT OF SPITS To place the spit into the appliance insert the “T” shaped, SPIT DRIVE HUB b on to the SPIT DRIVE SHAFT a .
OPERATING INSTRUCTIONS AR-6G Rotisserie Operation & Care Manual • 18 AR-6G Rotisserie Operation & Care Manual • 18 43 " (1092mm) 37 " (940mm) 2-3 " (51mm - 76mm) 2-3 " (51mm - 76mm) SKEWER PREPARATION & LOADING The appliance is furnished with six, removable skewers, each with 37" (940mm) of usable length.
CARE AND CLEANING AR-6G Rotisserie Operation & Care Manual • 19 AR-6G Rotisserie Operation & Care Manual • 19 1. Turn the burners OFF, d isconnect unit from power source and allow the appliance to cool. 2. Using hand protection, remove all detachable items such as spits.
CARE AND CLEANING AR-6G Rotisserie Operation & Care Manual • 20 AR-6G Rotisserie Operation & Care Manual • 20 MAINTENANCE CHANGING OF LIGHT BULBS Prior to opening the various sections, disconnect the electrical supply and close the gas valve located on the rear of the appliance.
SERVICE AR-6G Rotisserie Operation & Care Manual • 21 AR-6G Rotisserie Operation & Care Manual • 21 TROUBLESHOOTING GUIDE DEFECT OBSERVED POSSIBLE CAUSE REMEDY ELECTRICAL Spits and lamps do not work No power supply to unit. Verify unit has power to it.
SERVICE AR-6G Rotisserie Operation & Care Manual • 22 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 22 FULL ASSEMBLY - FRONT VIEW 1 20 7 11 5 21 14 6 13 20 8 9 12 19 4 2 16 15 18 21 22 13 3 10 17 ITEM PART NO.
SERVICE AR-6G Rotisserie Operation & Care Manual • 23 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 23 FINAL FLOOR ASSEMBLY - F.
SERVICE AR-6G Rotisserie Operation & Care Manual • 24 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 24 FINAL FLOOR ASSEMBLY - FRONT & BACK VIEW ITEM PART NO. DESCRIPTION QTY ITEM PART NO.
SERVICE AR-6G Rotisserie Operation & Care Manual • 25 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 25 MOTOR MOUNT ASSEMBLY 5 1 4 8 9 6 3 9 7 10 7 2 .59 " (15 mm) ITEM PART NO.
SERVICE AR-6G Rotisserie Operation & Care Manual • 26 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 26 TOP ASSEMBLY 12 5 6 18 C 3 24 20 4 10 23 8 1 14 22 21 27 21 9 11 17 2 15 26 E 19 27 16 13 13 25 28 7 ITEM PART NO.
SERVICE AR-6G Rotisserie Operation & Care Manual • 27 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 27 7 8 1 3 10 6 2 4 9 5 DET.
SERVICE AR-6G Rotisserie Operation & Care Manual • 28 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 28 GAS PLUMBING ASSEMBLY ITEM PART NO.
SERVICE AR-6G Rotisserie Operation & Care Manual • 29 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 29 A Remove the four screws (SC-2352) holding the glass light cover (CL-26608) and gasket (GS-26609) i n place, taking care to not let the glass cover fall into the oven.
AR-6G Rotisserie Operation & Care Manual • 30.
SERVICE AR-6G Rotisserie Operation & Care Manual • 31 Part numbers and drawings are subject to change without notice. AR-6G Rotisserie Operation & Care Manual • 31 Usethislistasanalcheckofapplianceinstallationconformance.
TRANSPORTATION DAMAGE and CLAIMS All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee.
Een belangrijk punt na aankoop van elk apparaat Alto-Shaam AR-6G (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Alto-Shaam AR-6G heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Alto-Shaam AR-6G vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Alto-Shaam AR-6G leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Alto-Shaam AR-6G krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Alto-Shaam AR-6G bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Alto-Shaam AR-6G kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Alto-Shaam AR-6G . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.