ATM ProBridge User Manual ii
Copyright Copyright © 2006, GE Security Inc. All rights reserved.
This document may not be copied or otherwise reproduced, in whole or in part, except as specifically permitted under US and international copyright law, without the prior written consent from GE.
Document number/ 0150-0315A (March 2006).
Disclaimer THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. GE ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS AND SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE LATEST DOCUMENTATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW.GESECURITY.COM
This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental.
GE and the GE monogram are registered trademarks of General Electric. PBe product and logo are trademarks of GE Security.
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
Intended use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation. For the latest product information, contact your local supplier or visit us online at www.gesecurity.com
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful inter- ference to radio communications.
You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
R Operation of this equipment in a residential area may cause inter- ference, in which case the user is required to take all measures that are necessary, at the user's expense, to correct the interference
Trademarks and patents · FCC compliance · Regulatory


ProBridge Ethernet User Manual iv

This is the GE ProBridge Ethernet User Manual for model PBe. This document includes detailed instructions explaining:
There is also information describing how to contact technical support if you have questions. To use this document effectively, you should meet the following minimum qualifications:
Read these instructions and all ancillary documentation entirely before installing or operating this product.

The following conventions are used in this document:
These terms may appear in this manual:

The PBe is a specific ProBridge unit for interfacing the DVR family of digital video multiplex/recorders to financial institution automated teller machines (ATMs). The PBe supports Ethernet network communications.
The PBe is compatible with all of the following DVR products:
The PBe components identified within this document provide means of capturing transaction data for use by the DVR family of digital video recording/transmission products. The PBe components translate the data into a usable format by the DVR and permits associating transaction data with specific cameras. GE assumes no responsibility for the amount and type of information available, the operation, non-operation, or erroneous operation of these third-party transaction products.

The PBe system consists of the ProBridge unit, this manual, an Ethernet cable, a PBe to DVR cable, a PBe to PC cable, and a power supply, as shown in Figure 1.
Figure 1. Product contents
4310-0034B PB3 to DVR cable

0150-0315 ProBridge Manual 4310-0061A PBe to PC cable
Inspect the package and contents for visible damage. If any components are damaged or missing, do not use the unit; contact the supplier immediately. If you need to return the unit, you must ship it in the original box.
You might also need the following:
PBe ProBridge · 4310-0040 Ethernet cable · Power Supply

Power. Ensure that the installation site’s AC power is stable
and within the rated voltage of the external power supply. If the site’s AC power is likely to have spikes or DIPs, use power line conditioning or an uninterruptible power supply.
Temperature. Observe the unit’s ambient temperature
specifications when choosing a location for the unit. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install this unit on top of other hot equipment.
Moisture. Do not expose the unit to rain or moisture.
Moisture can damage internal components. Do not install this unit near sources of water.
RS-232 limitations. Cable length between the POS device
and the PBe is limited to 50 ft. (15.24 m) Cable length between the PBe unit and the DVR is also limited to 50 ft. (15.24 m). If the supplied cables are replaced by custom made cables to address distances between components, ensure the cable is manufactured to ANSI standards for RS-232 communication.
The PBe is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.
Make sure installation is complete and all connections are made before applying power to the unit.


Before installation, please familiarize yourself with the PBe and its typical system layout.
Figure 2. PBe landmarks

Port 2/RS-232 Connects to the PC
Port 0/RS-485 Connects multiple PBes together
Power connection · Ethernet Port · Port 1/RS-232

The following figure shows a typical multiple ATM layout.
Figure 3. Multiple ATM system layout

4310-0034B RJ45 to RJ45 cable

The basic steps required to install the PBe are:
The following information is required for a successful PBe installation. This information is used to configure the PBe. You will need to contact the customer’s ATM network administrator for answers to these questions.

Table 1. Important switch assignments
SW1 1-4 Special functions
SW1 5-8 Camera assignment
SW3 1-8 Device type
Table 2. Default switch settings
1 Up 1 Up 1 Up 1 Up
2 Up 2 Up 2 Up 2 Up
3 Up 3 Up 3 Up 3 Up
4 Up 4 Up 4 Up 4 Up
5 Up 5 Up 5 Up 5 Up
6 Up 6 Up 6 Up 6 Up
7 Up 7 Up 7 Up 7 Down
8 Up 8 Up 8 Up 8 Up

setting switches 5-8 on SW1. See SW1 switches 5 to 8 on page 21.

After you install the PBe, you need to program the ProBridge for operation. This is accomplished by using HyperTerminal or manually setting the DIP switches.
You will need the following equipment to program the PBe using HyperTerminal:
To program the PBe with HyperTerminal, do the following:

Figure 4. Laptop connected to PBe

To program the PBe do the following:

Figure 5. HyperTerminal programming mode

Figure 6. Main menu


There are five menu selections on the Main Menu:
Selecting option #2 from the main menu launches the PBe Set-up menu.
Figure 7. The PBe Set-up menu

We recommend that you do not change the IP addresses from the defaults shown in Figure 7. The Ethernet Device option is the only option in this menu that you should change. To change the Ethernet device press 5 and then the enter key. The next device on

the list will be selected. The PBe supports the following Ethernet devices:
Selecting option #3 from the main menu launches the Terminal IP/Camera Set-up menu.
Figure 8. The terminal IP/camera set-up menu

Option #2 lets you associate cameras to terminals by the camera number and the terminals IP address. To associate a camera to a specific terminal do the following:

Figure 9. The camera/terminal IP table

Option #3 lets you enable/disable the Use IP for Camera command. When set to Enabled the PBe will search the incoming UDP and TCP packets for a match of IP addresses. Depending on the Device setting the PBe will parse the data received in that packet and send it to the associated camera number.
The fourth selection on the Main Menu is the Monitor Mode on/ off toggle. This selection will toggle between off and on when 4

ins entered followed by the enter key. Changing the selection to on allows the PBe to monitor the incoming Ethernet packets.
In some cases whenever SW3 is used to select the Ethernet Device, monitor mode will automatically be turned on.
This menu is used for troubleshooting only. Do not use unless requested by a qualified technician.
To exit HyperTerminal do the following:
The Ethernet Device and Camera Selection can also be selected manually by changing the DIP switch setting see DIP switch settings on page 20. Follow the steps below to change the DIP switches:


This chapter deals in detail with the DIP switch settings. The PBe must be re initialized before any changes to the switch settings will be recognized.
Switches 1 to 4 on SW1 are for turning monitor mode on or off.
Table 3. SW1 switches 1 to 4 - monitor mode
Function 1 2 3 4
Monitor OFF U
Monitor ON D U U U

Switches 5 to 8 on SW1 are for associating a specific camera on the DVR to the PBe.
Table 4. SW1 switches 5 to 8 - Camera number selection
Camera number 5 6 7 8
2 U U U D
3 U U D U
4 U U D D
5 U D U U
6 U D U D
7 U D D U
8 U D D D
9 D U U U
10 D U U D
11 D U D U
12 D U D D
13 D D U U
14 D D U D
15 D D D U
16 D D D D

The switch positions on SW3 are for selecting the Ethernet device type.
Table 5. SW3 switches 1 to 8 - Device type
Switch function 1 2 3 4 5 6 7 8
Ethernet Analyzer U
Generic U D
Native ATM U D U
Verifone POS U D D
These switches are reserved for technical support. Do not use.
Switches 7 and 8 on switch 4 control the communication protocol between the PBe at port 1 and the DVR or PC. Normally this is set at RS-232.
Table 6. SW4 switches 7 and 8 - communication protocol
Communication protocol 7 8
RS-485 U D

The PBe has a built-in webpage for simple configuration changes and remote upgrade. To access the webpage do the following:

Figure 10. The PBe home page

Click on any of the hyperlinked text to navigate to that feature’s page.

Use the table below to solve some of the most common problems
Table 7. Troubleshooting table
Problem Probable cause Solution
No red LEd Fuse is bad
No text on DVR text box
DVR baud rate incorrect
Change DVR baud rate to 57600
Cable not connected on PBe port #1
Not capturing data from switch
SPAN port not configured to echo data
Consult your IS group leader for this network

PBe
Operating temperature: 0 to 40º C.
Power consumption: 1.5 watts max.

Figure 11. 4310-0034B cable

Pin 1 · Pin 1

Figure 12. 4310-0061 cable


Figure 13. 4310-0040 PBe Ethernet


For assistance installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, you may contact technical support during normal business hours (Monday through Friday, excluding holidays, between 6 a.m. and 5 p.m. Pacific Time).
Table 8. Sales and support contact information
Phone Toll-free: 888.GESECURity (888.437.3287 in the US, including Alaska and Hawaii; Puerto Rico; Canada).
Outside the toll-free area: 503.885.5700.
E-mail info@gesecurity.com generaltech@ge.com
Fax 800.483.2495 541.752.9096 (24 hours/day)
Another great resource for assistance with your GE product is our online publication library, available to all of our customers. To access the library, go to our website at the following location:
In the Tools area at the top, click the Publication Library link. After you register and log on, you may search through our online library for the documentation you need.1
Sales Technical support
Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| No red LEd | Fuse is bad No Power | Replace fuse Check Power Supply | p.29 |
| No text on DVR text box | DVR baud rate incorrect Cable not connected on PBe port #1 | Change DVR baud rate to 57600 Check cable connections | p.29 |
| Not capturing data from switch | SPAN port not configured to echo data | Consult your IS group leader for this network | p.29 |