I T E M N O . W E L L S M A N U FA C T U R I N G

WV-FG, WV-2HG, WV-2HSG VENTLESS GRIDDLE/FRYER/COOKTOPS

VENTLESS GRIDDLE/FRYER/COOKTOPS

The ventless hood gives you the flexibility to “set up shop” just about anywhere from malls, stadiums and high-rise buildings to basement kitchens and kiosks.

GE WV-2HSG — WV-FG, WV-2HG, WV-2HSG VENTLESS GRIDDLE/FRYER/COOKTOPS diagram (page 1)
Afb. 1
  • Griddle (All Models)
  • Griddle surface (17 1/4”W x 18 1/4”D) has enclosed tubular elements that provide even heat distribution.
  • Griddle is controlled by a positive-off thermostat adjustable from 100ºF to 400ºF.
  • Griddle features include a full-width front grease trough , an extra-large removable front grease drawer and a stainless steel splashguard.
  • Fryer (WV-FG, WV-FGRW)
  • Two half-size, rear hanging, interchangeable fry baskets are provided.
  • Efficient heating element is flat, heavy-duty stainless steel.
  • Fryer on/off switch is located in recessed front control panel.
  • The positive-off thermostat controls the element allowing for adjustable and more consistent temperatures.
  • The fryer has a manual reset safety thermostat that will shut off the heating element if an over-temperature condition is reached.
  • Model WV-FGRW includes a Wells RW-26 built-in standard double drawer warmer that replaces lower storage cabinet.
  • Ventless Hood (All Models)
  • Ventless Hood System exceeds EPA Standard 202 for the release of particulate matter.
  • Interlock System will not allow heating elements to be energized if any of the filters are not in place.
  • Airflow Sensing System continually monitors airflow through the filtration system, optimizing performance and grease removal.
  • Ansul ® R-102 Fire Suppression System is built into the ventless hood to provide ultimate protection.
  • Shatter-resistent interior light for improved visibility.
  • Cooktop (WV-2HG, WV-2HSG, WV-2HGRW, WV-2HSGRW)
  • Model WV-2HG has two solid cast iron 9" french plate elements that are independently regulated by an infinite control with a positive-off position.
  • Model WV-2HSG has two spiral 8" elements that are independently regulated by an infinite control with a positive-off position.
  • Models WV-2HGRW and WV-2HSGRW include a Wells RW-26 built-in standard double drawer warme r that replaces lower storage cabinet.

WELLS

Page 2 of the GE WV-2HSG user manual — WV-FG 208 10750 30 43 24 NEMA 15-60P
Pagina 2 · klik om te vergroten
Pagina 2

W E L L S M A N U FA C T U R I N G

GE WV-2HSG — D I M E N S I O N S : diagram (page 2)
Afb. 2

W V-F G G R I D D L E , F RYE R

D I M E N S I O N S :

MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NASIDE SEE REQUIRED SPACERSBOTTOM 6 (152)TOP 8 (203)
COOKING SURFACE ILLUSTRATION GRIDDLE: 17 1/4 X 18 1/ UST FRYER 30 3/8 48 11/16 (771) (1237) 35 3/8 REQUIRED 6" CLEARANCE (898) SPACERS & SIDE 17 3/8 SHIELDS (441) OPENING 21 36 ROL (533) (914) L 27 1/16 22 3/4 (687) (578) /8 10)CONT PANE17 3/8 (441) OPENING ROL L 27 1/ (68
GE WV-2HSG — D I M E N S I O N S : diagram (page 2)
Afb. 3

W V-F G E LECTR I CAL S P EC I F I C AT I O N S :

MODELS VOLTS WATTS AMPS PER LINE 3 PHASE POWER SUPPLY CORD L1 L2 L3

WV-FG 208 10750 30 43 24 NEMA 15-60P

WV-FG 240 11650 26 40 24 NEMA 15-60P

WV-FGRW* 208 11425 32 43 26 NEMA 15-60P

WV-FGRW* 240 12550 28 40 27 NEMA 15-60P

*RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.

  • 05/02
  • REV(-)
  • PART NO. 304421-1

(1076)

Page 3 of the GE WV-2HSG user manual — WV-2HSG 208 8900 21 35 24 NEMA 15-60P
Pagina 3 · klik om te vergroten
Pagina 3

W E L L S M A N U FA C T U R I N G

GE WV-2HSG — D I M E N S I O N S: INCH (MM) diagram (page 3)
Afb. 4

M O D E L W V-2 H S G G R I D D L E , 2 S P I R A L E L E M E N TS

D I M E N S I O N S: INCH (MM)

MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NASIDE SEE REQUIRED SPACERSBOTTOM 6 (152)TOP 8 (203)
8 INCH SPIRAL ELEMENTS GRIDDLE17 1/4 X 18 1/4

W V-2H SG E LE CTR I CAL S P E C I F I CATI O N S:

MODELS VOLTS WATTS AMPS PER LINE 3 PHASE POWER SUPPLY CORD L1 L2 L3

WV-2HSG 208 8900 21 35 24 NEMA 15-60P

WV-2HSG 240 11100 23 38 24 NEMA 15-60P

WV-2HSGRW* 208 9575 23 35 26 NEMA 15-60P

WV-2HSGRW* 240 12000 26 38 27 NEMA 15-60P

*RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.

  • 05/02
  • REV(-)
  • PART NO. 304421-3
Page 4 of the GE WV-2HSG user manual — WV-2HG 208 8000 16 32 23 NEMA 15-60P
Pagina 4 · klik om te vergroten
Pagina 4

W E L L S M A N U FA C T U R I N G

GE WV-2HSG — WV-2HG 208 8000 16 32 23 NEMA 15-60P diagram (page 4)
Afb. 5

M O D E L W V-2H G G R I D D LE, 2 CAST I RO N E LE M E NTS

D I M E N S I O N S :

MINIMUM CLEARANCE REQUIRED FROM UNIT TO THE NEAREST SURFACE BACK NA NASIDE SEE REQUIRED SPACERSBOTTOM 6 (152)TOP 8 (203)
COOKING SURFACE ILLUSTRATION GRIDDLE: 17 1/4 X 18 1/4 UST 9" DIA SOLID CAST IRON ELEMENTS 30 3/8 (771) 48 11/16 (1237) 35 3/8 REQUIRED 6" CLEARANCE (898) SPACERS & SIDE 17 3/8 SHIELDS (441) OPENING ONTROL 21 36 ANEL (533) (914) 27 1/16 22 3/4 (687) (578) 1/8 10)C P17 3/8 (441) OPENING ONTROL ANEL
GE WV-2HSG — D I M E N S I O N S : diagram (page 4)
Afb. 6

W V- 2 H G E L E CT R I C A L S P EC I F I C AT I O N S :

MODELS VOLTS WATTSAMPS PER LINE 3 PHASEPOWER SUPPLY CORD L1 L2 L3

WV-2HG 208 8000 16 32 23 NEMA 15-60P

WV-2HG 240 9900 18 35 24 NEMA 15-60P

WV-2HGRW* 208 8675 19 32 26 NEMA 15-60P

WV-2HGRW* 240 10800 21 35 27 NEMA 15-60P

*RW Models include optional RW-26 built-in standard double drawer warmers. NOTE: Specifications are subject to change without notice. SPECIAL ENVIRONMENTAL NOTICE: The hood system is designed to reduce odor emissions but will not eliminate odors. Air exchange at the installation site must comply with requirements of the local jurisdictional authority. To ensure dilution of odor build-up, minimum recommendation is 400 cubic feet of fresh air per minute both in and out of the area.

  • WELLS MANUFACTURING COMPANY 2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A. USA PHONE: (77 5) 689-5700
  • FAX: (775) 689-5972 FOR ORDERS ONLY: (888) 356-5362
  • FAX: (800) 356-5142 <a href="http://www.wells-mfg.com" rel="nofollow noopener" target="_blank">www.wells-mfg.com</a> © 2002 WELLS MANUFACTURING
  • PRINTED IN THE U.S.A. 05/02
  • REV(-)
  • PART NO. 304421-2

(1076)

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de GE WV-2HSG

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de GE WV-2HSG

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

GE WV-2HSG handleiding-pdf

4 pagina's·399 KB·Kookplaat·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…