Gebruiksaanwijzing /service van het product 005220-0 van de fabrikant Generac Power Systems
Ga naar pagina of 60
ST ANDBY GENERA T OR O WNER'S MANU AL This manual should remain with the unit. A ne w standar d of reliability Serial Number QT 3.0L 30kW Model: 005220-0 — CAUTION — ONL Y QU ALIFIED ELECTRICIANS OR CONTRA CT ORS SHOULD A TTEMPT INST ALLA TION! Cover025 Re v .
Standby Generator Sets T able of Contents SECTION P AGE SAFETY RULES ................................................ 1-1 INTRODUCTION ..................................................... 1-3 Read this Manual Thoroughly ..............................
Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reli- ably only if it is properly installed, operated and maintained.
• Before performing any maintenance on the gen- erator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step.
1-3 I NTRODUCTION Thank you for purchasing this model of the standby generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written.
I DENTI F ICA TION R EC ORD D A T A LA BE L Every generator set has a DA T A LABEL that contains important information pertinent to the generator . The data label, which can be found attached to the g.
E QUIPM ENT DE SCRI PTION This equipment is a revolving field, alternating cur - rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units.
ENGI N E P RO TE CTIVE DEVICE S The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm.
F U E L SYST E M FUE L RE QUIRE MEN T S The standby generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing .
SP ECIF ICA TIONS GEN ERA T OR T ype ............................................................................. Synchronous Rotor Insulation ............................................................ Class F or H Stator Insulation ...............
COLD WEA THER KIT F or cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: • Battery W armer • 4” Junction Box with hardware • 6 qt. pack 5W -30 synthetic oil (engine) R EC ON F IGU R I NG TH E F U EL SY STEM NOTE: All models are configured for natural gas or LP vapor from the factory .
GEN ER A T OR A C LEAD C ONN ECTIONS See “V oltage Codes”. This generator may be rated at any one of three voltages, either single -phase or three -phase. The electrical wires in the unit ’s AC con- nection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application.
I NST ALL A TION Refer to the separate “Installation Guide QT Product Line” supplied with the unit. P R EP ARA TION B EFOR E S T ART -U P The instructions in this section assume that the standby generator has been properly installed, ser - viced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor .
S T ART -U P CH ECKLIS T Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 120V AC supply to the battery charger is switched OFF . P REP AR A TION FOR S T ART -UP • Ensure that the 120V AC circuit breaker to the bat - tery charger is open.
GEN ER A T OR C ONTROL AND OP ER A TION Refer to the appropriate control panel operator’s manual for this unit. OP ER A TI NG U N IT WITH MAN U AL TR ANSF ER SWIT CH If the generator was installed in conjunction with a transfer switch capable of manual operation only , the following procedure applies.
MAI NTENANCE P ER FOR M ED B Y AUTHOR IZED SERVICE F A CILITI ES Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 15A fuse has been removed from the con- trol box. • The 120V AC supply to the battery charger is switched OFF .
ENGI NE COOL ANT Check coolant level in coolant recovery bottle. See the “Specifications” section. • Add recommended coolant mixture as necessary . • Periodically remove radiator pressure cap to make sure the coolant recovery system is functioning properly .
7. Start engine and check for oil leaks. Figure 10.2 - Oil Filter Oil Filter CHANGI NG THE ENGI N E AI R CLEAN ER T o replace the engine air cleaner , (part number 0A4637), remove the air cleaner cover and replace the air filter making sure it is positioned properly before reattaching the cover .
BA TTER Y MAI NTENANCE The battery should be inspected per the “Service Schedule” section. The following procedure should be followed for inspection: 1. Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary .
SERVICE S CH EDU LE 30 KW - 1 5 0 KW ST ANDBY GAS ENGIN E DR IVEN GEN ER A T OR SET S The following is a recommended maintenance schedule for standby gas engine driven generator sets from 30kW to 150 kW in size. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
TROU B LESHOO TING GU I DE P ROB LEM CAUSE C OR R ECTION Engine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse . 2. Loose or corroded or defectiv e 2. Tighten, clean or replace batter y cables. batter y cables as necessary . 3. Defectiv e star ter contactor .
Standby Generator Sets Notes.
.
1 0F3137 1 PAN CB CONN BOX 2 0F3188 1 STAND RH CONTR OL 3 0F3189 1 STAND LH CONTRO L 4 0 23484N 1 B U SHING SNAP SB-2.5 -31 5 *** 0F6366B 1 / 2 XFMR DU AL 120 V/16 V (FO R 12 0/ 240V & 277/ 480V U.
.
1 0 F3438 1 RTR 390 30AD1 C PL 0F344 0 1 RTR 39 0 40AD2 C PL HI-EF 0F61 88 1 AS S Y RTR 39 0 30 KD 1 CP L 0F61 90 1 AS S Y RTR 39 0 40 KD 2 CP L 2 0F3439 1 STR 390 30 AD 1 CP L 0F34 41 1 S TR 39 0 40 .
.
COMPONENTS INCLUDED IN 01827E 1 0F1823A 1 ENCL HSB CO NT ROL PANE L 2 0F3078 1 COVER CO NTRO L PANEL 3 0F2606 1 HINGE CONT INUOUS H-PAN EL 4 036261 6 RI VET POP .125 X . 275 SS 5 043 181 4 SCREW PHM M3-0.5 X 10MM 6 052777 7 WASHE R FL AT M 3 7 0F4245E 1 AS SY PCB CPL CT RL R 1800 RPM 8 0 F1262 4 HOLDER FUSE W ICKMANN 178.
.
1 0F3270A 1 MTG BASE 3.0L 30K W C2 2 0528 60 4 NUT FL ANGE D HEX M 12- 1.7 5 3 0522 51 4 DAMPE NE R VI BRAT ION 40 BLUE 4 052 257 4 SPAC ER .49 X .62 X 1.87 PWDR/ZNC 5 0522 52 4 DAMPE NE R VI BRAT ION 6 0522 59 4 WASHE R F LAT M 12 7 0528 91 4 SCRE W HH C M 12-1.
.
1 0F3408 1 TRAY BA TTER Y 2 0F 3 4 11 1 STRAP BA TTE RY RETAI NMENT 3 058208 RE F BAT T 12VD C 24 F 62 5 4 036833 1 SCRE W HH C 3/ 8-1 6 X 1 G8 5 022237 1 WASHE R LO CK 3/8 6 022131 1 WASHE R F LAT 3/8- M10 Z IN C 7 050331A 1 BATT POST COVER RED + 8 0 50331 1 BATT POST COVER BLK - 9 038805 H 1 CAB LE BA TT BL K #1 X 2 3.
.
1 0E5 19 3 1 P LATE AIR CLE ANE R AD AP T ER 2 0E0519A 1 AD APTER CAR BU RETOR W/PV C CONN 3 0221 27 1 NUT HEX 1/4- 20 STE EL 4 0629 74 1 STU D TH 1/4- 20 X 4- 1/2 G 2 ZN C 5 0526 19 4 SCREW HH C M 5-0.
.
1 0F6842 1 E NGINE 3 .0L FORD (FD) ( MAKE) CPL 2 02 2131 14 WASHER FL AT 3/8- M10 ZIN C (1800 RPM O NLY) 022131 * 9 WASH ER FLAT 3/8-M10 ZINC (3 60 0 R PM ONLY) 3 0E8 96 3 1 PULLE Y CR AN KS H AFT 3.0L F O R D (180 0 RPM ON LY ) 0E6309 1 P ULLE Y CR AN KSH AFT 3.
.
1 0F3203A 1 WELDMEN T RAD SUPPO RT 3.0L C 2 2 0356 8 5 6 CLAM P HOS E #2 8 1. 32- 2. 25 3 0F2608A 1 RADIAT OR 598 X 568 X 49,CP L LH 4 0F67 61 1 HOSE UP PE R RAD CPL C2 3.0L 5 0F32 28 1 HOS E LOW E R RA D CPL C2 3.0L 6 0F51 43 1 S PA CER FAN 3. 0L C2 7 0F02 30 A 1 FAN COOL I NG 16" DI A 8 BLA DE 8 0457 64 1 SCRE W HH TT M4- 0.
.
.
.
1 0 26915 2 NI PPLE C LOSE 3 /4 X 1.375 2 075580 1 FLANGE FUEL INLET 3 0F6390 1 REGULATOR ASSEMBLY D UAL FUEL 4 03925 3 2 S CREW HHC M 8-1. 25 X 20 G8.8 5 02214 5 2 W ASHE R FL AT 5/ 16-M 8 ZIN C 6 0 22129 4 WASH ER LOCK M8 -5 /1 6 7 045771 2 NUT HEX M 8-1.
.
1 0F0738 1 MUFFLER 7" X 9"-(2) 2" IN/2. 5" OUT 2 0F28 08B 1 P IPE EXHAUS T MUFFLE R 4 0F2830 1 MUFFLER BRACKE T STIFFENE R 5 0F2962 1 MUFFLER STR AP 6 0 807 62 1 BOLT U 3/ 8-1 6 X 2. 62 7 0E0170 B 1 EXHAUST BLANK ET 80 0MM (C2) 8 0 E0170 1 EXHAUST BLANKET 75 0 MM (C2) 9 0F4343 1 EXHAU ST PIPE 3.
.
1 0F58 53 (XX ) 1 REA R WRA P C2 2 0C24 5 4 68 S CRE W THF M6- 1 X 16 N WA Z/JS 3 0F58 49 ( XX) 2 DO OR C2 4 087 233 2 RIVET POP .187 5 X .4 50 SS 5 0E 325 7 4 SCREW TH- FR M M6 W/ CAP S HKP RF W 6 0 .
.
.
.
.
.
.
.
.
.
.
Standby Generator Sets W arranty Printed in U.S.A. GENERA C PO WER SYSTEMS ST ANDARD LIMITED W ARRANTY FOR HOME ST ANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELO W For a period of two (2) y ears from the date of sale, or start-up by A uthorized/Cer tified Generac P ow er Systems Dealer , or branch thereof , Generac P ow er Systems, Inc.
Een belangrijk punt na aankoop van elk apparaat Generac Power Systems 005220-0 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Generac Power Systems 005220-0 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Generac Power Systems 005220-0 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Generac Power Systems 005220-0 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Generac Power Systems 005220-0 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Generac Power Systems 005220-0 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Generac Power Systems 005220-0 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Generac Power Systems 005220-0 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.