Gebruiksaanwijzing /service van het product R-200A van de fabrikant Generac Power Systems
Ga naar pagina of 16
TECHNICAL MANU AL This manual should remain with the unit. R-200A Digital Contr oller A ne w standar d of reliability.
IM PORT ANT SAFETY INSTRUCTIONS R-panel T echnical Manual SA VE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted in potential hazard areas. Safety should be stressed to all operators and potential operators of this equipment.
T able of Contents R-panel T echnical Manual 1 Safety Rules ........................................ Inside Front Cover General Information ......................................................... 2 Introduction ......................................
I NTRODUCTION The R-200A Controller incorporates the generator control circuitry , the ignition coil driver circuitry and the interface circuitry to an external governor driver . The R-200A Controller can control a; 4- cylinder , 1.6L, 1800 rpm or 3600 rpm engine 4- cylinder , 2.
3 Jumper JMP1/S2: Selects the engine displacement. Set to position 1 and 2 for 1.6L. Set to position 2 and 3 for 2.4L. The jumper is not used on PCB's 0G1505A or 0G1505B. On later revisions, JMP1 is replaced by S2. S2 has no effect on 4.2L operation and is ignored when DIP Switch P osition 7 is ON .
4 General Information R-panel T echnical Manual Switch P osition Condition System Low Low Low High Over Over Manual A uto Off Ready Fuel Bat Oil T emp Speed Crank Generator Switch is OFF @ X OFF OFF O.
5 GEN ERA T OR OP ERA TION The R-200A controller monitors the front panel switch position and reads the DIP switch position set - tings when the control board is initially powered-up. In the OFF position the controller will only be incre - menting the exercise timer and monitoring the bat - tery voltage and low fuel pressure sensor .
6 General Information R-panel T echnical Manual A CTIVE AL ARM Low Oil Pressure, High Coolant T emp, Low Coolant Level, Overspeed, Overcrank, Engine Speed Signal Loss and a Dead Battery indication will all be latched shutdowns.
7 D ANGER With the switch set to AUTO, the engine can crank and start suddenly without warning. Such automatic start up normally occurs when utility source voltage dr ops below a pre-set level.
8 R PM SIGNAL F AI L U R E (F LASHI NG R ED O VERSP EED IN DICA T OR) If the R-200A controller does not receive a signal from the engine flywheel sensor , the R-200A control- ler cannot maintain the generator output frequency or monitor for an overspeed condition.
9 Be very careful when connecting high-voltage wires labeled N1 and N2 and low-voltage wir es labeled 23 and 194 in both the generator wiring panel and the transfer switch wiring panel. The control boar d will be damaged if these wires are not connected correctly .
10 Route the 2-wire start control wires through suit - able, approved conduit which is separate from the AC power leads. Connection of wire 178 to wire 183 by relay contact closure action (volt free switch con- tacts) in the transfer switch must result in generator engine cranking and startup (see Figure 5).
11 R-200A J1 C ON NECT OR (23 PI N, GRA Y=1 800 R PM, WH ITE=3 600 R P M) Pin # 1 Governor 12V Supply 2 Reserved (Do not connect any wires to this pin.
12 D ANGER Storage batteries give off explosive hydr ogen gas. This gas can form an explosive mixture around the battery for several hours after charg- ing. The slightest spark can ignite the gas and cause an explosion. Such an explosion can shat- ter the battery and cause blindness or other injury .
13 Notes R-panel T echnical Manual.
Part No. 0G1341 GENERAC ® POWER SY STEMS, INC. P .O. BOX 8 W AUKESHA, WI 53187 Revision E (06/19/07) Printed in U.S.A..
Een belangrijk punt na aankoop van elk apparaat Generac Power Systems R-200A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Generac Power Systems R-200A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Generac Power Systems R-200A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Generac Power Systems R-200A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Generac Power Systems R-200A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Generac Power Systems R-200A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Generac Power Systems R-200A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Generac Power Systems R-200A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.