BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 1 BTR HA NDBOOK TABLE OF CONTENTS PAGE PAG E Troubleshooting (continued) I.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 2 Qualifications: Installation or service of this water heater requires ability equivalent to that of a licensed tr adesman in the field invol ved.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 3 INSTALLATION This portion of the handbook will review some often overlooked installation considerations, taki ng note of necessary install ation requir ements for the BTR 120 through 500 model heater s.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 4 EXTERIOR CLEARANCE This illustrates t he exterior roo f clearance s for BTR units with na tural draft ve nting.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 5 AIR FOR COMBUSTION 10 CUBIC FEET OF AIR PER 1, 000 BTU Stoichiometr ic or theoretical complete com bustion requir es 10 cubic feet of air per 1000 BTUH input of the gas input.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 6 MAKE-UP AIR DIRECT COMMUNICATION A fresh supply of make-up air for com bustion can be suppli ed to the heater through make-up air ducts which directly com municate wi th the out of doors.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 7 MAKE-UP AIR VERTICAL DUCTS Often it is mor e practical to install ver tical make-up air ducts to the out doors.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 8 MAKE-UP AIR HORIZONTAL DUCTS When the heater is installed in an inter ior room with no roof access for vertical ducts, horizontal m ake-up air ducts should be installed.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 9 INSUFFICI ENT MAKE-UP AIR BACKDRAFT Insufficient make-up air is a major cause of c ombustion probl ems.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 10 CONTAMINATED AIR Along with adequate m ake-up air , the quality of the air is important. Contaminants i n combustion air can lead to pr emature heater fai lure.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 11 GAS PRESSURE REQUIREMENTS Natural Gas Propane Gas Maximum Suppl y Pressure 13.8" w.c. 13.8" w.c. Minimum Supply Pressure 4.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 12 BTR GAS VALVE The gas valves used on all BTR water heaters ar e 24 volt AC combi nation step opening gas val ves. They incorpor ate the pilot val ve, main val ve, and gas pressure regul ators into one body.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 13 VENTING Atmospheric Multi ple Heaters All BTR water heater s are classified by ANSI as category I ( non-condensing, negative pressure venting) appliances.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 14 DRAFT INDUCER Draft inducer s can be used wit h BTR water heater s to mechanical ly aid a l azy chimney in vertical vent applications.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 15 POWER VENT KITS FOR SIDEWALL VENTING Water Heater Models Part Number BTR-120-200 193933-0 BTR-250-500 193933-1 BTR water heater s can be used with power vent kits for sidewal l venting.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 16 BTR SEQUENCE OF OPERATION 1. Thermostat calls for heat 2. Flue dam p er o p ens 3. Intermittent I g nition Control 5. Main gas valve opens 7.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 17 BTR ELECTRICAL SEQUENCE 100 – 109 Series.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 18 BTR ELECTRICAL SEQUENCE OF OPERATI ON Mo t o r Ope n s Da m pe r Po w e.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 19 TROUBLESHOOTING BTR WATER HEATERS To troubleshoot a BTR water heater ch.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 20 STEP 2 HIGH LIMI T, LEFT TERMINAL TEST STEP 2. HIGH LIMIT, LEFT TERMINAL TEST. Test for 24 VAC between the left high limi t terminal and ground.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 21 STEP 3 TEST HIGH LIMI T RIGHT TERMINAL STEP 3. TO TEST HIGH LIMIT RIGHT TERMINAL . Ensure that the jumper wire between the high lim it and thermostat is connected, and the dam per motor pow er line i s connected.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 22 STEP 4 INSPECT THE DAMPER STEP 4. INSPECT THE DAMPER. Lower the thermo stat setting so the unit will not b e calling for heat, then inspect the damper.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 23 STEP 6 PC BOARD MOTOR TEST STEP 6. PC BOARD/MOTOR TEST. Check for 24 VAC between the tw o motor lead terminal s of the PC board.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 24 STEP 7 THERMOSTAT TEST STEP 7. THERMOSTAT TEST. Set the thermostat to call for heat. Using your multim eter, test for 24 VAC between right term inal and ground.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 25 GO TO PAGE 27 FO R DAMPER TESTS O F EFFIKAL EQUI PPED (SERIES 110, 111 AND RET ROFIT ) MODEL S STEP 8 DAMPER INPUT TEST STEP 8.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 26 STEP 10 TEST DAMPER OUTPUT STEP 10. TEST DAMPER OUTPUT. On a call for heat, the damper relays recei ves power through the y ellow w ire and power to the motor is interrupted.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 27 Damper 1 23 4 Bl ack Red Ye llo w Wh i te Or ange Br own Yello w Black Male P lug From Heater 2 1 3 4 Female Plug EFFIKAL DAMPER BTR Series 110 and 111 began using the motor open; motor close, Effikal D amper.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 28 HARNESS CHART Heater Harness Function Damper Harness Black 24V Hot 1-Br.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 29 NORMAL OPERATION (conti nued) Condition: • Thermostat closed, damper in process of opening STEP B TEST FOR 24VAC BETWEEN BLACK AND ORANGE IF THEN 24VAC is pr esent Continue to Step C.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 30 TROUBLESHOOTING THE EFFIKAL STYLE DAMPER Condition: Thermostat closed, .
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 31 TROUBLESHOOTING THE EFFIKAL STYLE DAMPER (continued) Condition: Thermos.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 32 STEP 11 WIRE HARNESS TEST STEP 11. WIRE HARNESS TEST. Test for 24 VAC between terminal 24V on the IID module, and 24V (GN D).
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 33 STEP 12 IID MODU LE TEST STEP 12. IID MODULE TEST ( Power to the Pilot Valve). Using a multimeter, test for 24 VAC between terminal PV and 24V (GND) on the IID during the 90 second trial for ignition.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 34 STEP 13 PILOT SPARK TEST STEP 13. PILOT SPARK TEST. Visually check for spark at the pilot assembly. Note: The pilot burner mounts on the left side of the main burner .
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 35 STEP 14A PILOT VALVE - OHM TEST BTR 120 – 400 GA S VALVE STEP 14A. PILOT VALVE - OHM TEST. If pilot assembly is sparking but no pi lot flame is establis hed, disconnect the pilot valve solenoid leads.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 36 STEP 14B PILOT VALVE TEST – BTR 500 ONLY STEP 14B. PILOT VALVE TEST – BTR 500 ONLY. Testing the two co ils of the Honeywell VR 8404P 5004 gas valve used on the model BTR 500 only.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 37 STEP 15 MAIN BURNER TEST Note: BTR seri es 108 and 109 implemented a new mai n burner stamping process – burners appear the same as illustrated.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 38 STEP 16 FLAME RECTIFICATI ON STEP 16. FLAME RECTIFICATION Note: Flame rectific ation means that an alternating cur rent (AC) signal is changed to a direc t current ( DC) signal.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 39 STEP 17 IID MODU LE TEST Pilot is lit - Sparking has stopped. STEP 17. IID MODULE TEST (Power to th e Main Valve). Using a multimeter, test for 24 VAC between term inal MV on the IID and 24V (GND ).
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 40 STEP 18A MAIN GAS VALVE CHECK BTR 120 – 400 GA S VALVE STEP 18A. MAIN GAS VALVE CHECK. Disconnect wires fr om gas valve TH and TR terminals.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 41 STEP 18B MAIN GAS VALVE COIL CHECK STEP 18B.
BTR TANK TYPE HEATERS SERVICE HANDBOOK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 42 BTR WIRING DI AGRAM - NATURAL AND PROPANE GAS Honeywell Ignition Syst em (110 – 109 Series) IF ANY OF THE ORI GINAL WIRE AS S UPPLI ED MUST BE REPLACE D, USE ONLY TYPE 105° C THERM OPLASTI C OR EQUIVALEN T.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 43 GENERAL SERVICE CHART CONDITION CAUSE SOLUTION DAMPER OPENS NO POWER TO IID MODULE . DAMPER NOT FULLY OPEN . DEFECTIVE PROTECTOR SWITCH .
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 44 GENERAL QUESTIONS AND ANSWERS Q. What chan ges caused series 106/107 and 108/109 t o be implement ed? A. The 106 and 107 series units changed from the momentary push button to a slide switch.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 45 BTR MODELS 197 AND 198 Series 100-101.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 46 BTR MODELS 197 AND 198 (continued) Series 100-101.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 47 PARTS LIST for BTR Models 197 and 198 Series 100 & 101 Item Parts Description BTR 197 BTR 198 1 Bracket For Main Burner Orifice.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 48 BTR MODELS 120 through 500 Series 104-105.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 49 BTR MODELS 120 through 500 (continued) Series 104-111.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 50 PARTS LIST FOR BTR Models 120 Thr ough 500(A) Series 104 Through 109 Ser ies (Series 106/107 have a service sw itch on Circuit Board 6522; Series 108/109 have new main burner production method.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas ©2000 Training Depart ment 51 COMPONENT PART INFORMATIO N NA ME SPECIFICA TIONS A OS PART.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas © 1999 Training Depart ment 52 BTR SERVICE CHECKLIS T (This service checklist may be photo copied to assist with BTR service call.) This checklist is intended to aid the Servi ce Agent in determ ining that the A.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas © 1999 Training Depart ment 53 Is the system properly si zed? yes no Is the system proper.
B T RT A N KT Y P EH E A T E R S SERVICE WORKBO OK A.O. Smith Water Pr oducts Servic e Handbook Irving, Texas © 1999 Training Depart ment 54 COMMENTS Author: Terr y Mulder.
Een belangrijk punt na aankoop van elk apparaat A.O. Smith 120 trough 500 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen A.O. Smith 120 trough 500 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens A.O. Smith 120 trough 500 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding A.O. Smith 120 trough 500 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over A.O. Smith 120 trough 500 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van A.O. Smith 120 trough 500 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de A.O. Smith 120 trough 500 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met A.O. Smith 120 trough 500 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.