C US ® RT6612018 Rev. 5 April 2010 GMH95 40" 95% Gas Furnace • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information.
PRODUCT IDENTIFICA TION 2 Minior Revision A 3 Description Air Flow Direction KBTUH AFUE Major Revision Maximum CFM @ 0.5" ESP 3 : 1200 4 : 1600 5 : 2000 Cabinet Width The model and manufacturing number are used for positive identification of component parts used in manufacturing.
PRODUCT IDENTIFICA TION 3 GMH950453BXA* GMH950703BXA* GMH950704CXA* GMH950904CXA* GMH950905DXA* GMH951155DXA* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chart for details. 4. Installer must supply the following gas line fittings, de- pending on which entrance is used: Left -- Two 90º Elbows, one close nipple, straight pipe.
5 COMPONENT IDENTIFICA TION Upflow/Horizontal 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Pressure Switch 4 Gas Manifold 5 Combustion Air Intake Connection / “Coupling” 6 Hot Surface Igniter 7 R.
COMPONENT IDENTIFICA TION 6 GMH95*****XA* Cabinet Size A B C D E 13-5/ 8 17-1/ 2 20-7/ 8 All d imensions ar e in inches. 24-1/ 2 12-1/ 8 16 19-3/ 8 12-1 5/16 15-1 5/16 20-7/16 GMH950453B XA* GMH950703.
7 PRODUCT DESIGN TRIP POIN T COIL COVER PRESSURE SWITCH COIL C OVER PRESSURE SWITCH PART # TRIP POI NT ID BLOWER PRESSURE SWITCH ID B LOWER PRESSURE SWITCH PART # TR IP POI NT COIL C OVER PRESSURE SWITCH TRIP POI NT ID BLOWER PRESSURE SWITCH HIGH ALTITUDE KIT GM H950453BXA* -1.
8 PRODUCT DESIGN P ar t N u mb er 10123514 o r 10123533 O pe n S e tt ing ( ° F ) 200 G M H 950453B XA * 1 G M H 950703B XA * 2 G M H 950704C XA * 2 G M H 950904C XA * 2 G M H 950905D XA * 2 G M H 95.
9 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GMH95 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device).
10 PRODUCT DESIGN Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return air filters at the side and/or bottom return.
FURNACE SPECIFICA TIONS 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level.
BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furn ace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium-speed heating.
BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 110 12 0 100 13 0 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU/H R x 1000 BTU OUTPUT vs T EMPERAT UR E RISE CHART T EM PER AT U R E R IS E 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU T = CFM x 1 .
14 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAB GMH95[0703,0904,1 155]*XAC HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICING OR INS T ALLIN G THIS UNIT .
15 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAC GMH95[0703,0904,1 155]*XAD R YL YELLO W OR O RA.
Een belangrijk punt na aankoop van elk apparaat Goodman Mfg GMH95 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Goodman Mfg GMH95 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Goodman Mfg GMH95 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Goodman Mfg GMH95 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Goodman Mfg GMH95 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Goodman Mfg GMH95 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Goodman Mfg GMH95 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Goodman Mfg GMH95 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.