C opyright ©2009-2010 Goodman Manufacturin g Company, L.P. RT6621020 Rev. 1 April 2010 GME8 33-3/8" 80% Gas Furnace Up flow/Horizont al • Refer to current Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual.
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GME80703BXC* GME80905CXC* GME81155CXC* All models are low NOx models.
4 PRODUCT DESIGN NOTE: Gas furnaces with induced draft blowers draw products of combustion through a heat exchanger allowing, in some instances, common venting with natural draft appliances (i.e. water heaters). All installations must be vented in accordance with National Fuel Gas Code NFPA 54/ANSI Z223.
5 PRODUCT DESIGN Accessibility Clearances (Minimum) Unobstructed front clearanace of 24" for servicing is rec- ommended. Top clearance for horizontal confirguration - 1" MINI M UM CL EARAN CE T O C O MBUST IBLE MATE RIA LS - INCH E S SW B 10 3 C 6 1 1 ** Si ngle Wal l V en t (S W) t o b e us ed o nl y as a c onn ec t or.
PRODUCT DIMENSIONS 6 GME8*****XA UN I T S A B C D G ME 80 7 03 B X C * 1 7 . 5 16 33 -3/ 8 28 G ME 80 905 CXC* G ME 81 155 CXC* 21 19 .5 3 3- 3 / 8 2 8 A l l dim e n s ion s a re in i nch e s .
7 PRODUCT DESIGN * All installas above 7,000 ft. require a pressure switch change. For installations in Canada, the GME8 furnace is certified only to 4,500 ft.
8 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the new GME8 furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device).
9 PRODUCT DESIGN Thermost at s: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards.
10 PRODUCT DESIGN Dual$aver Configuration & Operation Dual$aver This furnace is capable of the following heating modes: Single Stage (Factory Setting) Modifi ed T wo-Stage Fixed 5-Min Low Stage A.
FURNACE SPECIFICA TIONS 11 Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation.
BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. 2. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed.
BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 11 0 120 100 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 OUTP UT BTU/ HR x 1 000 BTU OUTPUT vs T EMPERATURE RI SE CHA RT TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT = CFM x 1.
14 WIRING DIAGRAMS HI GH V OL T AGE! DISC ONNECT ALL POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . MUL TIPL E POW ER SOURCES MA Y BE P RESENT . F AI LURE TO DO SO MA Y CAUSE PROP ERTY DAMAG E, PERSONAL I NJURY OR DEA TH. Wiring is subject to change.
15 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MUL TIPL E POW ER SOUR CES MA Y BE PRESENT .
16 SCHEMA TICS HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MUL TIPL E POW ER SOUR CES MA Y BE PRESENT . F A ILURE T O DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL INJURY OR DEA TH .
Een belangrijk punt na aankoop van elk apparaat Goodman UPFLOW/HORIZONTAL GME8 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Goodman UPFLOW/HORIZONTAL GME8 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Goodman UPFLOW/HORIZONTAL GME8 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Goodman UPFLOW/HORIZONTAL GME8 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Goodman UPFLOW/HORIZONTAL GME8 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Goodman UPFLOW/HORIZONTAL GME8 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Goodman UPFLOW/HORIZONTAL GME8 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Goodman UPFLOW/HORIZONTAL GME8 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.