Gebruiksaanwijzing /service van het product PCMA 15KE-410 van de fabrikant Amcor
Ga naar pagina of 15
PORT ABLE AIR CONDITIONER GB User manual PCMA 9KE-410 12KE-410 15KE-410.
2 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference.
3 • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer , its service agent or a qualified person in order to avoid a hazard.
4 Slide bar connector Active carbon filter T elescopic slide bar Exhaust hose W ater container Remote control with LCD PA R T S 9 5 7 6 8 3 1. Air outlet 2. Control panel 3. C arrying handle 4. Caster wheels 5. Upper air inlet 6. Exhaust air outlet 7.
5 CON TROL P ANEL GB F an ON/ UP Clock/ OFF Timer Mode Sensor DOWN Sleep remote control F an speed Clock/timer T emperature Cooling Sleep mode Timer settings DISPL A Y.
6 INS T ALL A TI ON WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another . In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles.
7 ON/OFF Press to switch the unit on, to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash.
8 Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00.
9 Air flow Direct the air flow by adjusting the grill on top of the air conditioner . Move the grill, by pushing or pulling, in the middle (see illustration). This will avoid uneven positioning of the grill. Adjusting the air flow is as also possible by moving the direction of the vertical louvres.
10 The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function.
11 This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air , which includes a. A screen filter , to remove dust particles. b. An active carbon filter , to remove odours. 2.
12 EMP T YING THE INTER NAL W A TER CONT AINE R Under high humidity conditions it may be necessary to empty the internal water container . When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically .
13 Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property . Problem Cause Solution The air conditioner does not function. No power supply . Connect to a functioning outlet and switch on.
14 Reminder: W aste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. TECHNI CA L DA T A Model PCMA 9KE-410 PCMA 12KE-410 PCMA 15KE-410 Cooling capacity measured conform EN 14511 BTU/h 7500 9900 11300 kW 2.
A M C P Hong Kong China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.
Een belangrijk punt na aankoop van elk apparaat Amcor PCMA 15KE-410 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Amcor PCMA 15KE-410 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Amcor PCMA 15KE-410 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Amcor PCMA 15KE-410 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Amcor PCMA 15KE-410 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Amcor PCMA 15KE-410 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Amcor PCMA 15KE-410 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Amcor PCMA 15KE-410 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.