ProDispense™
Used to meter and dispense paints, coatings, solvents, water, and lubrication fluids. For Professional Use Only.
Not for use in explosive atmospheres.

Conforms to ANSI/UL standard 3121-1 CAN/CSA C22.2 No 1010-1-92



Follow the instructions in this manual (309301) and refer to the component manuals for addi- tional warning, operation, service, and parts information. See the table below for:
ProDispense Controller Part No. 244561 Parts List Page No. 62
Remote Operator Station Part No. 116669
ProDispense System Components

The following conventions are used in this manual to help guide you through the information.
Symbols, such as fire, explosion, or electric shock hazard (shown at left), alert you to the spe- cific hazard. Read the main Warnings on pages 6-7 for detailed information about the hazard indicated.
1 ID# 1. Enter the ID number.
Conventions · Amount 20 qts · Recipe#

WARNING
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in fire, explosion or electric shock.
TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

WARNING
HIGH PRESSURE FLUID HAZARD/SKIN INJECTION HAZARD
Fluid Panels 244599 and 244601 can be operated at very high fluid pressure (see page 4). High pres- sure spray from dispense valves, hoses, or ruptured components can inject fluid into your body and cause an extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury.
The following precautions should be taken for high pressure fluid dispensing:
LOW PRESSURE FLUID HAZARD Fluid Panel 244600 is for low pressure use only (see page 4). Fluid coming from the dispense valves, leaks or ruptured components can splash in the eyes or on the skin and cause serious injury.
The following precautions should be taken for either high or low pressure fluid dispensing:

How the ProDispense System Works
The ProDispense system enables you to accurately dispense preset amounts of up to three different fluids or to manually dispense fluid as desired. The fluid meters provide accurate fluid flow readings to the controller. Controller totalizers use the meter flow readings to calculate fluid volume and usage and display the information on the screen. The controller can store the parameters for up to 250 recipe dispenses.
The ProDispense system can dispense fluids supplied from pressure tanks or feed pumps. Each fluid is supplied separately to the ProDispense fluid panels.
You can choose Fluid Dispense mode to individually enter a fluid preset volume and dispense the fluid. Or you can choose Recipe Dispense mode to dispense a preset recipe. A recipe allows you to select or set up to three preset fluid volumes simultaneously.
Regardless of which dispense mode you choose, a dispense tolerance must be entered for each fluid. The controller monitors the Target and Actual dispense values and reports an error if the tolerance is not maintained.
Overview


ProDispense Controller with display and EasyKey™ pad
10’ (3.05 m) station cable standard*
50’ (15.24 m) meter & solenoid cables
*20’ (6.1 m) station cable extension 198456 is available.
The controller is used to setup the ProDispense system, fluids, and recipes, calibrate the meters, and select a recipe or preset a dispense. The controller totalizers enable you to view fluid dispense information and print the following reports:
The EasyKey™ pad is the operator interface for the ProDispense system. The keypad con- sists of number keys, enter key, scrolling (arrow) keys, and operation (start, stop, clear, and print) keys.
The graphic LCD screen displays system status, setup information, and operation options that can be selected using the keypad.


Start Stop Clear Print
Number Keys — type in setup or operation data.
Enter Key — press to accept and enter data.
If you press a scrolling key without pressing Enter, the cursor will move to the next field and the information you typed will reset back to the previous data.
Scrolling Keys — press the up or down arrows to move between fields on the screen. Use the left or right arrows to move between screens.
Operation Keys — use to operate the ProDispense system functions.
Start — press to start the current recipe dispense.
Stop — press to stop the current process.
Clear — press to clear an entry in an input field.
Print — press to print a report.

On = Off = .
(On side of controller)
The position of the switch (B) determines which mode of operation you are in: Dispense Mode or Setup Mode . A key (C) supplied with the ProDispense system is inserted into the switch and turned to change operation modes. The key cannot be removed while the system is in Setup Mode.
Dispense Mode is used to dispense a recipe, fluid, check fluid totals, and to view the alarms log.
Setup Mode is used to configure the system, fluid, and recipe parameters, and to cali- brate the meters.
DISPENSE AUTO ON
A cable connects the operator station to the fluid panel junction box. A separate operator sta- tion is needed for each fluid panel installed on the system. The dispense switch can be set to dispense automatically (AUTO) or manually (ON).
If set to AUTO, the fluid panel will dispense when a recipe or fluid dispense is selected with the controller and the start button is pressed either on the controller or the operator station. The dispense will stop when the preset amount is reached or when the stop button is pressed on either the controller or the operator station.
If set to ON, the fluid panel will begin dispensing immediately or when the dispense valve is triggered. The dispense is stopped by releasing the trigger or turning the dispense switch to AUTO or pressing the STOP button on the operator station.

There are six types of fluid panels available:
Signals from the controller and operator station communicate to the fluid panel(s) when to start and stop dispensing. Signals from the fluid panel’s fluid meter communicate to the con- troller how much fluid has been dispensed.



D
D
E
E
E
F
H
H
H
Key A Controller Solenoid Connection B Controller Meter Connection C Operator Station Connection D Junction Box E Fluid Inlet F Meter G Solenoid H Fluid Outlet I Air Inlet J Fluid Valve
Overview




D
D
E
E
F
F
Key A Controller Solenoid Connection B Controller Meter Connection C Operator Station Connection D Junction Box E Fluid Inlet F Meter G Solenoid H Fluid Outlet I Air Inlet J Fluid Valve
Overview · 246838 246837 246839

Do not install or service this equipment unless you are trained and qualified.
Do not install the ProDispense controller, fluid panels, or remote operator station in a hazardous location.
Key for FIG. 5 1 ProDispense Controller with EasyKey™ Pad 2 Remote Operator Station 3 Oil/Lubricant Fluid Panel (244599) 4 Water/Antifreeze Fluid Panel (244600) 5 Grease/Paint Fluid Panel (244601) 6 Fluid Supply Pump 7 Fluid Supply 8 Air Supply Line 9 Dispense Valve 10 Ground Wire to true earth ground 11 Fluid Supply Line 12 Fluid Dispense Line 13 Fluid Shutoff Valve 14 Bleed-type Air Shutoff Valve 15 Optional Printer
Installation


The ProDispense fluid panels can be supplied by pressure tanks, pail or drum pumps, or cen- tral recirculating lines.
The fluid supply must be free of pressure spikes, commonly caused by a pump stroke changeover. If necessary, install pressure regulators or a surge tank on the fluid supply out- lets. Note that this will also reduce the fluid supply pressure.
Installation

Mount the fluid panel(s) on a flat, sturdy surface. Install 1/4” or M6 fasteners in the four 0.28” mounting holes (C1) and secure the fluid panel (C) to the mounting surface. Connect a ground wire (G) as instructed on page 20.
13.4” (315 mm)
12.4” (340 mm)
Connect the fluid supply line (11) to the 1/2” npt(f) meter inlet. See FIG. 5. Connect a fluid dis- pense line (12) to the 1/2” npt(f) solenoid outlet. Connect the other end to the dispense valve (9).
Connect an air supply line (8) to the 1/4” npt(f) solenoid valve port. The air supply must be fil- tered to 10 micron to lengthen solenoid valve life.
Connect the fluid supply line (11) to the 1/4” npt(f) meter inlet. Connect a fluid dispense line (12) to the 3/8” npt(m) outlet of the dispense valve on the fluid panel. Connect the other end to the dispense valve (9).
Installation · 8” (203 mm) · 9” (229 mm)

Connect an air supply line (8) to the 1/4” npt(f) solenoid valve port. The air supply must be fil- tered to 10 micron to lengthen solenoid valve life.
Connect the fluid supply line (11) to the meter inlet. Connect a fluid dispense line (12) to the 3/8” npt(m) outlet of the dispense valve on the fluid panel. Connect the other end to the dis- pense valve (9).
Connect an air supply line (8) to the 1/4” npt(f) solenoid valve port. The air supply must be fil- tered to 10 micron to lengthen solenoid valve life.
Connect the fluid supply line (11) to the 3/4” npt(f) meter inlet. Connect a fluid dispense line (12) to the 3/8” npt(m) outlet of the dispense valve on the fluid panel. Connect the other end to the dispense valve (9).
Mount the operator station (D) in a convenient location for the operator. Secure it with No. 10 or M5 fasteners through the four 0.22” mounting holes (D1). Connect the cable (D2) to the fluid panel junction box connector marked C.
20 ft. (6.1 m) station cable extension 198456 is available.
D
Installation

Mount the controller on a flat, sturdy surface as instructed below.
A3 B
A1
B1
17.38” (441 mm)
14.5” (368 mm)
8.5” (216 mm)
11.3” (287 mm)
Installation · TI1436a A2

On the bottom of the controller, there are meter and solenoid cable connectors for three Fluid panels. The row of connectors marked 1A, 2A, and 3A are for solenoid cable connections. The row of connectors marked 1B, 2B, and 3B are for meter cable connections. Connect the cables as instructed below.
A knockout, marked , is provided for a customer supplied power input (P) cable with strain relief or for wire conduit.
P
Installation · TI1438a E

The system must be properly grounded. Follow the instructions here and on page 6.
ProDispense Controller: Connect a ground wire (G1) to the grounding lug (H1) on the bottom of the controller. Connect the other end of the ground wire to a true earth ground.
Fluid Panels: Connect a ground wire (G) to the grounding lug (H) on the junction box bracket. Connect the other end of the ground wire to a true earth ground.

Feed Pumps or Pressure Pots: See your separate pump or pressure pot manual.
Air and Fluid Hoses: Use only grounded hose.
Fluid Supply Container: Ground the container according to your local code.
Solvent Pails Used when Purging: Ground pails according to your local code. Use conductive, metal pails, placed on a grounded surface. Do not place pails on nonconductive surfaces, such as paper or cardboard.
To reduce the risk of fire, explosion, or electric shock, the resistance between the ProBatch components and true earth ground must be less than 1 ohm.
Have a qualified electrician check the resistance between each ProDispense component and true earth ground. If the resistance is 1 ohm or greater, a different ground site may be required. Do not operate the system until the problem has been corrected.
Installation

Connect the 5 ft. (1.52 m) printer cable (provided with printer kit 239873) between the printer and controller printer connector marked . See FIG. 5, page 15.
Accessory Printer Cable 198669, 50 ft. (15.24 m) long, is available. Do not use longer cables.
The ProDispense system can be connected to a PC via Modbus RTU network protocol (6) and/or audible alarms (7) as shown in FIG. 12. Refer to field wiring chart, page 60. Follow instructions on page 26 to setup modbus station number and recipe selection. Contact your Graco distributor for Modbus address mapping list.
Installation

Installation

Follow this procedure to start the ProDispense system for the first time (initial startup) or after the system has been shut down.
Startup · FloSync · Startup screen

Follow this procedure to relieve pressure in the fluid panel and dispense line before cleaning, checking, or servicing the equipment or installing or cleaning a dispense valve nozzle.
Follow the additional instructions in brackets if a dispense valve is installed on the dispense line.
DISPENSE AUTO ON
DISPENSE AUTO ON
Shutdown
Follow this procedure before servicing the equipment and to avoid having fluid dry in the equipment and fluid lines when the equipment is not being operated.
Pressure Relief Procedure · Dispense Switch ON · Dispense Switch AUTO

Screen Navigation
You must have the key supplied with the system. Insert the key into the switch and turn it to Setup Mode . The System Setup screen appears.
Do not turn the key to Setup Mode while the ProDispense is dispensing or the system will abort the dispense.
Language:
System Fluids Recipes Meters
The name of the screen that is currently displayed is highlighted.
Press the left or right arrow keys on the keypad to move through the screens.
Press the up or down arrow keys to move through data fields on the screen.
Turn the key to Dispense Mode. The Run screen appears. Refer to page 30.

Use system setup to enter the date, time, language to display, dispense mode, means of rec- ipe selection and station number.

The ProDispense clock is a 24 hour clock. The date and time are used for date/time stamps on alarms and reports.
Power must be cycled before the language change will take affect.
Fluid Station: use this mode to select individual fluid stations when dispensing.
Recipe: use this mode to select a recipe when dis- pensing. Dispensing by recipe will signal all fluid sta- tions included in the recipe to dispense simultaneously.
User Interface: use to select recipes from the EasyKey pad.
Network: use to select recipes from a networked source.
This number is used for network communications to identify the station. Each station must have a unique number.
Setup Mode · System

Use fluid setup to designate the parameters for each fluid you will dispense.
Fluid parameters must be set before the fluid can be used in a recipe.

Fluid 1 Fluid 2 Fluid 3 Units of Measure
You can have 1-3 fluid panels connected to the ProDis- pense controller. Setup the fluids for each of your fluid panels as follows:
1=cc 2=oz 3=Qt 4=Ltr 5=Gal Tolerance % Timeout Value (min) K-factor (cc/pulse)
If a dispense does not complete by the end of the entered value, a Dispense Timeout alarm occurs. See page 33.

244599 oil/lubricant 4.73 244600 water/antifreeze 25 244601 grease/coating 0.119 246837 grease/coating .061 246838 grease/coating n/a 246839 grease/coating 0.286
The K-factors in the table are a starting point. You can calibrate the meter as instructed on page 28.
Setup Mode · Fluids

Use recipe setup to configure your recipes by assigning a recipe number and designating Tar- get Amounts for each fluid in the recipe.

Type in 0 if a fluid is not used in the recipe. The units of measure are set in Fluid Setup (page 27).
Use this screen to calibrate your fluid panel meters. All values are in cubic centimeters (cc).
Follow the additional instructions in brackets if a dispense valve is installed on the dispense line.

(cc) Fluid 1 04.730 0 Fluid 2 00.119 0 Fluid 3 25.000 0 1) Manually dispense fluid into a calibrated container (minimum of 300 cc). 2) Type in Actual Value and Press ENTER.
If nothing is entered in the Actual column, the K-fac- tor remains unchanged.
Setup Mode · Recipes · Meters

Screen Navigation
Dispense Mode is used to dispense a fluid or recipe, check fluid dispense totals, and view the alarms log.

Fluid 1 Fluid 2 Fluid 3 Idle Idle Idle Target 005.00 ltr 050.00 ltr 010.10 ltr Actual 5.00 ltr 51.00 ltr 10.00 ltr
Tolerance % 5 5 5 Difference % 0 +2 -1
The name of the screen that is currently displayed is highlighted.
The Operator Station dispense switch must be set to AUTO to dispense using the controller.
Press the left or right arrow keys on the keypad to move through the screens.
Press the up or down arrow keys to move through data fields on the Run screen.

Use the Run screen to dispense a recipe or individual fluids. The Run screen displays either Recipe Dispense or Fluid Dispense, depending on which Dispense Mode was selected in System setup.
In each of the fluid columns, under the Fluid panel number, is a status line, which shows the status of the associated fluid panel. The three possible statuses are:
Idle — fluid panel is idle (not dispensing).
Dispense — fluid panel is dispensing.
Alarm — controller has detected the fluid panel has an alarm condition. To view alarm information, press the right arrow key twice to move to Alarm screen. Refer to page 33.

Recipe Dispense displays in the Run screen if “Recipe” is selected as the Dispense Mode. Recipe Dispense is used to dispense a set amount of fluid, typically from more than one fluid panel simultaneously.
Fluid 1 Fluid 2 Fluid 3 Idle Idle Idle Target 005.00 ltr 050.00 ltr 010.10 ltr Actual 5.00 ltr 51.00 ltr 10.00 ltr
Tolerance % 5 5 5 Difference % 0 +2 -1
The Target value is set in Recipe Setup. You cannot change it in the Run screen.
DISPENSE START
START

Fluid Dispense displays in the Run screen if “Fluid Sta- tion” is selected as the Dispense Mode. Fluid Dispense allows you to select a fluid panel and the amount to dis- pense on an individual basis.
Fluid 1 Fluid 2 Fluid 3 Idle Idle Idle Target 005.00 ltr 050.00 ltr 010.10 ltr Actual 5.00 ltr 51.00 ltr 10.00 ltr
Tolerance % 5 5 5 Difference % 0 +2 -1
DISPENSE AUTO ON
START

Press the left or right arrow key to select Totals. The Fluid Totals screen shows how much of each of the fluids has been dispensed overall. Two totals are shown. Grand totals are tracked from the time the system is first started up and they are not resettable. Resettable totals show the total amount of each fluid dispensed since the last reset.
Press Print key to print Fluid Totals Report.
Fluid# Resettable Grand 1 00005.1 ltr 00312.1 ltr 2 00005.2 ltr 00582.8 ltr 3 00004.8 ltr 00468.2 ltr Last Reset Date:23/04/01 Time: 07:35 Press ENTER and CLEAR to reset totals
Press Clear and Enter keys simultaneously to reset all resettable totals.
All resettable totals are reset when Clear and Enter are pressed. Fluid totals cannot be reset individually.

Press the left or right arrow key to select Alarms. This screen summarizes the last five alarms that have occurred.
Press Print key to print an Alarms Report. ALARMS
Date Time Description Recipe Fluid 03/09 9:39 Invalid K-factor 10 1 03/08 14:32 Out of Tolerance 0 1 03/05 15:01 Timeout 6 2 03/05 8:12 Out of Tolerance 6 2 03/02 10:59 Invalid K-factor 0 3
This alarm occurs when the current actual dispense is either less than target – tolerance or greater than target + tolerance.
The controller stops an active dispense and initiates this alarm when the current dispense is not finished by the end of the Timeout. Timeout is a value entered during Fluid Setup (page 27).
This alarm occurs if the meter K-factor is set to zero (00.000).
This alarm occurs when the memory has been replaced but not programmed or when the memory has become corrupt.
See page 36 for alarm troubleshooting information.

Wear eye protection whenever you are dispensing fluid.
Follow the additional instructions in brackets if a dispense valve is installed on the dispense line.
Follow this procedure to load the fluid lines and purge out any air:
STOP Dispense Switch ON
DISPENSE START
START
Refer to page 30 for instructions on dispensing a recipe or page 31 to dispense individual fluids.
Operation Procedures

Follow this procedure to purge the fluid lines:
To stop fluid flow at all the fluid panels connected to the controller, press the Stop button on the controller.
Fluid 1 Fluid 2 Fluid 3 Idle Idle Idle Target 005.00 ltr 050.00 ltr 010.10 ltr Actual 000.00 ltr 000.00 ltr 000.00 ltr
Tolerance % 5 5 5 Difference % -98 -99 -97
To stop fluid flow at an individual fluid panel, press the STOP button on the Operator Station connected to the fluid panel.
STOP
DISPENSE AUTO ON
DISPENSE START
Operation Procedures · Run Totals Alarms · Stop

Out of Tolerance Alarm Dispense is under or over tolerance limit set for the fluid.
Run screen shows tolerance difference for last dispense. Use the value to determine whether you should:
Dispense Timeout Alarm The dispense did not complete within set Dispense Timeout value.
Check the following:
Service equipment as needed.
Invalid K-factor Alarm Meter K-factor is set to zero (00.000). Set valid meter K-factor (page 27).
Memory Failure Alarm The system is not configured. Enter setup values (page 25).
The memory is corrupt. Replace flash EPROM.
No display No power Turn on or reconnect power.
Faulty cable(s) Replace cable(s).
Blown fuse(s) Replace fuse(s).
Troubleshooting

Wear a grounding strap when replacing any of the controller boards to avoid shorting them out.
Check with your Graco distributor periodically to see if circuit board or software updates are available.
To remove controller:
F
B
P
P
TI1438a E

To install controller:
A
A1
A2
B1


D

Spacers (G) must be used in correct positions to protect the display and board.

If replacing software chip, use a chip puller to remove it.



N
K
M
M

M
J





a. Disconnect fluid line from the meter. Loosen two nuts (A) holding the meter and remove meter. See FIG. 22.
b. Secure new meter (4) with the nuts (A). Continue with step 6.
a. Disconnect fluid lines from meter and solenoid.
b. Remove two bolts (6) and washers (7) from the solenoid (3), and remove solenoid and meter assembly. See FIG. 22.
c. Place flats of the solenoid (3) in a vice and unscrew the meter (4).
d. Secure new solenoid (3) to the meter with the nut (A).
e. Secure meter and solenoid assembly to the fluid panel with solenoid washers (7) and bolts (6).

A

Remove fittings from old components and reinstall in new components as needed.
a. Place flats of the solenoid (3) in a vice and unscrew the meter (4).
b. Screw new meter into connector (A).
a. Place flats of the solenoid (3) in a vice and unscrew the meter (4).
b. Unscrew dispense valve (19) from the solenoid (3).
c. Screw new dispense valve into connector (C).
d. Screw the meter into the connector (A).
a. Place flats of the solenoid (3) in a vice and unscrew dispense valve and meter assembly.
b. Screw new solenoid (3) into connector (B).

B
Show meter removal

Remove fittings from old components and reinstall in new components as needed.
a. Place flats of the solenoid (3) in a vice.
b. Unscrew dispense valve (19) from the solenoid (3).
c. Screw new dispense valve into connector (C).
a. Place flats of the solenoid (3) in a vice and unscrew dispense valve.
b. Screw new solenoid (3) into connector (B).

B

Remove fittings from old components and reinstall in new components as needed.
a. Place flats of the solenoid (3) in a vice and unscrew the meter (4).
b. Screw new meter into connector (A).
a. Place flats of the solenoid (3) in a vice and unscrew the meter (4).
b. Unscrew dispense valve (19) from the solenoid (3).
c. Screw new dispense valve into connector (C).
d. Screw the meter into the connector (A).
a. Place flats of the solenoid (3) in a vice and unscrew dispense valve and meter assembly.
b. Screw new solenoid (3) into connector (B).

B
Show meter removal

Wire / Harness Connection (Connector-Pin) Color Function
Fuse 1 PWR SW 1A black
Fuse 2 PWR SW 2A black
PWR SW 1 P Supply L black
PWR SW 2 P Supply N black
GND TB P Supply G green/yellow
P Supply G P Supply - green/yellow
P Supply - J7-3 blue ground
P Supply + Fuse 3 blue
Fuse 3 J7-4 blue
J7-4 J7-1 blue jumper
J7-1 terminal block red 24 VDC power
J9-9 J9-10 blue jumper
J10-1 J10-2 blue jumper
J10-2 J10-3 blue jumper
J10-3 J10-4 blue jumper
terminal block P-1 red 24 VDC power
J9-5 P-2 red stop PB
198556 Main PCB to 7 pin
J9-6 P-4 black start PB
J6-2 P-5 red solenoid
J6-1 P-6 black ground
ring terminal P-7 green ground
terminal block P-1 red 24 VDC power
J9-3 P-2 red stop PB
198556 Main PCB to 7 pin
J9-4 P-4 black start PB
J6-4 P-5 red solenoid
J6-3 P-6 black ground
ring terminal P-7 green ground

Wire / Harness Connection (Connector-Pin) Color Function
terminal block P-1 red 24 VDC power
J9-1 P-2 red stop PB
198556 Main PCB to 7 pin
J9-2 P-4 black start PB
J6-6 P-5 red solenoid
J6-5 P-6 black ground
ring terminal P-7 green ground
J11-7 P-1 red 24 VDC power
198557 Main PCB to 4 pin
J11-8 P-2 black ground
J11-9 P-3 clear meter signal
ring terminal P-4 drain ground
J11-4 P-1 red 24 VDC power
198557 Main PCB to 4 pin
J11-5 P-2 black ground
J11-6 P-3 clear meter signal
ring terminal P-4 drain ground
J11-1 P-1 red 24 VDC power
198557 Main PCB to 4 pin
J11-2 P-2 black ground
J11-3 P-3 clear meter signal
ring terminal P-4 drain ground
J2-6 P-1 black ground
116726 Main PCB to 3 pin
J2-7 P-2 clear printer
J3-1 J4-1 brown RS485_B
197827 Main board to
J3-2 J4-2 white RS485_A
J3-3 J4-5 black ground
J3-5 J4-3 green DSRI
J3-10 J4-4 red VCC
197835 Front panel to
J1-1 SW1 black key switch
J1-2 SW2 red key switch

Harness Connection (Connector-Pin) Color Function
198426 Control box to fluid
panel (1A, 2A, 3A)
198427 Control box to fluid
panel (1B, 2B, 3B)
F1 2POS SW NC 2 orange
F2 2POS SW NO 3 orange
F3 Start PB X1 orange
F4 Start PB NO 4 brown
F5 2POS SW NO 4 brown
F6 Stop PB NC 1 brown/green
F7 Start PB NO 3 white
F8 Start PB X2 black/green
F9 Ground Lug green
F10 Stop PB NC 2 red
F11 Stop PB NC 1 blue
F12 Ground Lug shield
stop PB NC 2 2POS SW NC 1 blue jumper

Harness Connection (Connector-Pin) Color Function
T Block 1 Pin-1 orange
T Block 2 Pin-2 white
197573 6 pin bulkhead operator station
T Block 3 Pin-5 black
T Block 4 Pin-4 blue
244660 Fluid panel junction box
T Block 7 Pin-6 red
T Block 1 Pin-1 orange
Terminal block 5 & 6
T Block 2 Pin-2 white
197574 7 pin bulkhead (A) cable connection
T Block 3 Pin-6 red
Terminal block 7 & 8
T Block 4 Pin-4 blue
T Block 5 Pin-5 black
244600, 244601 fluid panels
ring terminal Pin-7 green/yellow
T Block 9 Pin-1 red
T Block 10 Jumper
197575 4 pin bulkhead (B) cable connection
T Block 11 Pin-2 black
T Block 12 Pin-3 white
T Block 13 Pin-4 G/Y & shield
meter wires TB 11 black
244599 Fluid panel (oil)
solenoid wires TB 8 black
meter wires TB 11 white
244600 Fluid panel (water)
solenoid wires TB 8 black
meter wires TB 11 black
246837 246839 244601 Fluid panel (grease)
solenoid wires TB 8 black

Harness Connection (Connector-Pin) Color Function
Harness Connection (Connector-Pin) Color Function
197458 (5 ft., 1.52 m)
198669 (50 ft. 15.24 m)
Harness Connection (Connector-Pin) Color Function
J5-2 General Alarm (24 VDC)
J5-4 Fluid 1 Alarm (24 VDC)
J5-6 Fluid 2 Alarm (24 VDC)
J5-8 Fluid 3 Alarm (24 VDC)


Part No. 244561, Controller

Parts

Ref. # Part # Description Qty.

9, 10, 11, 12, 20
Ref. # Part # Description Qty. 1 116421 PANEL, fluid dispense 1 2 197576 BLOCK, solenoid mount 1 3 110025 VALVE, solenoid 1 4 238618 METER, electronic pulse, see Manual 308245 for parts 1 5 158491 FITTING, nipple, 1/2-14 npt 1 6 102313 SCREW, cap, 1/4-20 UNC-2A x 1.75” 2 7 110755 WASHER, plain, 0.281” ID 6 8 102040 NUT, lock, hex, 1/4-20 UNC-3B 2 9 104029 CLAMP, ground 1 10 104582 WASHER, tab, 5.3 mm ID 1 11 100718 WASHER, lock, #10 1 12 105332 NUT, lock, hex, M5 x 0.8 1 13 244660 JUNCTION BOX, electrical 1 14 101577 SCREW, cap, hex hd., 10-24 UNC-2A x 0.375” 2 15 C38163 WASHER, lock, star, #10 2 16 100021 SCREW, cap, hex hd., 1/4-20 UNC-2A x 1” 2 17 112514 FERRULE, wire, AWG 18 (not shown) 2 18 112512 FERRULE, wire, AWG 26-22 (not shown) 3 20 237569 WIRE ASSY., 25 ft. (7.6 m) 1 21 116669 OPERATOR STATION, remote 1 22 198426 HARNESS, wire 1 23 198427 HARNESS, wire 1

9, 10, 11, 12, 20
Ref. # Part # Description Qty. 1 116421 PANEL, fluid dispense 1 2 197576 BLOCK, solenoid mount 1 3 110025 VALVE, solenoid 1 4 513891 METER, pulse, water 1 6 102313 SCREW, cap, 1/4-20 UNC-2A x 1.75” 2 7 110755 WASHER, plain, 0.281” ID 6 8 102040 NUT, lock, hex, 1/4-20 UNC-3B 2 9 104029 CLAMP, ground 1 10 104582 WASHER, tab, 5.3 mm ID 1 11 100718 WASHER, lock, #10 1 12 105332 NUT, lock, hex, M5 x 0.8 1 13 244660 JUNCTION BOX, electrical 1 14 101577 SCREW, cap, hex hd., 10-24 UNC-2A x 0.375” 2 15 C38163 WASHER, lock, star, #10 2 16 100021 SCREW, cap, hex hd., 1/4-20 UNC-2A x 1” 2 17 112514 FERRULE, wire, AWG 18 (not shown) 2 18 112512 FERRULE, wire, AWG 26-22 (not shown) 3 20 237569 WIRE ASSY., 25 ft. (7.6 m) 1 21 116669 OPERATOR STATION, remote 1 22 198426 HARNESS, wire 1 23 198427 HARNESS, wire 1


7, 19, 23, 24
Ref. # Part # Description Qty. 1 116421 PANEL, fluid dispense 1 2 156971 NIPPLE, short, 1/4-18 npt 1 3 116463 VALVE, solenoid 1 4 239716 METER, gear, G3000, see Manual 308778 for parts 1 6 112173 MUFFLER, 1/4-18 npt 1 7 181256 NEEDLE, fluid 1 8 110249 ADAPTER, male, 90° elbow, 1/4-18 npt 1 9 104029 CLAMP, ground 1 10 104582 WASHER, tab, 5.3 mm ID 1 11 100718 WASHER, lock, #10 1 12 105332 NUT, lock, hex, M5 x 0.8 1 13 244660 JUNCTION BOX, electrical 1 14 101577 SCREW, cap, hex hd., 10-24 UNC-2A x 0.375” 2 15 C38163 WASHER, lock, star, #10 2 16 156823 UNION, swivel, 1/4-18 npt 2 17 112514 FERRULE, wire, AWG 18 (not shown) 2 18 112512 FERRULE, wire, AWG 26-22 (not shown) 3 19 205612 VALVE, dispense, automatic, see Manual 306715 for parts 1 20 105468 SCREW, cap, hex hd., M6 x 12 2 21 110755 WASHER, 0.281” ID 2 22 244661 CABLE, G3000 meter (not shown) 1 23 164749 TIP, valve 1 24 164111 WASHER, 0.465” ID 1 25 237569 WIRE ASSY., 25 ft. (7.6 m) 1 26 116669 OPERATOR STATION, remote 1 27 198426 HARNESS, wire 1 28 198427 HARNESS, wire 1
Parts


7, 19, 23, 24
Ref. # Part # Description Qty. 1 116421 PANEL, fluid dispense 1 2 156971 NIPPLE, short, 1/4-18 npt 1 3 116463 VALVE, solenoid 1 4 244292 METER, gear, G3000 HR, see Manual 308778 for parts 1 6 112173 MUFFLER, 1/4-18 npt 1 7 181256 NEEDLE, fluid 1 8 110249 ADAPTER, male, 90° elbow, 1/4-18 npt 1 9 104029 CLAMP, ground 1 10 104582 WASHER, tab, 5.3 mm ID 1 11 100718 WASHER, lock, #10 1 12 105332 NUT, lock, hex, M5 x 0.8 1 13 244660 JUNCTION BOX, electrical 1 14 101577 SCREW, cap, hex hd., 10-24 UNC-2A x 0.375” 2 15 C38163 WASHER, lock, star, #10 2 16 156823 UNION, swivel, 1/4-18 npt 2 17 112514 FERRULE, wire, AWG 18 (not shown) 2 18 112512 FERRULE, wire, AWG 26-22 (not shown) 3 19 205612 VALVE, dispense, automatic, see Manual 306715 for parts 1 20 105468 SCREW, cap, hex hd., M6 x 12 2 21 110755 WASHER, 0.281” ID 2 22 244661 CABLE, G3000 meter (not shown) 1 23 164749 TIP, valve 1 24 164111 WASHER, 0.465” ID 1 25 237569 WIRE ASSY., 25 ft. (7.6 m) 1 26 116669 OPERATOR STATION, remote 1 27 198426 HARNESS, wire 1 28 198427 HARNESS, wire 1
Parts


7, 19, 23, 24
Ref. # Part # Description Qty. 1 116421 PANEL, fluid dispense 1 3 116463 VALVE, solenoid 1 6 112173 MUFFLER, 1/4-18 npt 1 7 181256 NEEDLE, fluid 1 8 110249 ADAPTER, male, 90° elbow, 1/4-18 npt 1 9 104029 CLAMP, ground 1 10 104582 WASHER, tab, 5.3 mm ID 1 11 100718 WASHER, lock, #10 1 12 105332 NUT, lock, hex, M5 x 0.8 1 13 244660 JUNCTION BOX, electrical 1 14 101577 SCREW, cap, hex hd., 10-24 UNC-2A x 0.375” 2 15 C38163 WASHER, lock, star, #10 2 16 156823 UNION, swivel, 1/4-18 npt 2 17 112514 FERRULE, wire, AWG 18 (not shown) 2 18 112512 FERRULE, wire, AWG 26-22 (not shown) 3 19 205612 VALVE, dispense, automatic, see Manual 306715 for parts 1 22 244661 CABLE, G3000 meter (not shown) 1 23 164749 TIP, valve 1 24 164111 WASHER, 0.465” ID 1 25 237569 WIRE ASSY., 25 ft. (7.6 m) 1 26 116669 OPERATOR STATION, remote 1 27 198426 HARNESS, wire 1 28 198427 HARNESS, wire 1
Parts


7, 19, 23, 24
Ref. # Part # Description Qty. 1 116421 PANEL, fluid dispense 1 2 15B556 NIPPLE, short, 1/4-18 npt 1 3 116463 VALVE, solenoid 1 4 246190 METER, heli gear, amb with sensor (see manual 309834 for parts) 1 6 112173 MUFFLER, 1/4-18 npt 1 7 181256 NEEDLE, fluid 1 8 110249 ADAPTER, male, 90° elbow, 1/4-18 npt 1 9 104029 CLAMP, ground 1 10 104582 WASHER, tab, 5.3 mm ID 1 11 100718 WASHER, lock, #10 1 12 105332 NUT, lock, hex, M5 x 0.8 1 13 244660 JUNCTION BOX, electrical 1 14 101577 SCREW, cap, hex hd., 10-24 UNC-2A x 0.375” 2 15 C38163 WASHER, lock, star, #10 2 16 156823 UNION, swivel, 1/4-18 npt 2 17 112514 FERRULE, wire, AWG 18 (not shown) 2 18 112512 FERRULE, wire, AWG 26-22 (not shown) 3 19 205612 VALVE, dispense, automatic, see Manual 306715 for parts 1 20 117028 SCREW, cap, hex hd., M6 x 16 2 21 115226 WASHER, M6 2 22 198578 CABLE, G3000 meter (not shown) 1 23 164749 TIP, valve 1 24 164111 WASHER, 0.465” ID 1 25 237569 WIRE ASSY., 25 ft. (7.6 m) 1 26 116669 OPERATOR STATION, remote 1 27 198426 HARNESS, wire 1 28 198427 HARNESS, wire 1 29 193715 FITTING, union, swivel 1
Parts


Electrical 115/230 VAC, 1.6 amp maximum, 50 or 60 Hz Pneumatic (Model 244601 only)
85-120 psi (0.59-0.9 MPa, 5.9-9 bar) at 1/4 cfm maximum (filtered to 10 micron) Number of fluids 1-3 valves Totalizers Last dispense Resettable Grand No. of Recipes 250 maximum Cable Lengths
Meter Signal 50 ft. (15.24 m) Solenoid signal 50 ft. (15.24 m) Operator Station 10 ft. (3.05 m) 20 ft. (6.10 m) available Fluid Panels
244599 Oil /Lubricant Flow rate 0.25-4 gpm (0.95-15 lpm) Viscosity range 10 wt. oil - #2 grease Accuracy + 1/2% on dispenses over one gallon Resolution 4.73 cc/pulse Maximum Working Pressure 1500 psi (10 MPa, 103 bar) Fluid inlet 1/2 npt(f) Fluid outlet 1/2 npt(f) 244600 Water/Antifreeze Flow rate 0.25-4 gpm (0.95-15 lpm) Viscosity range 1-20 cps Accuracy + 3% on dispenses over one gallon Resolution 25 cc/pulse Maximum Working Pressure 250 psi (1.7 MPa, 17 bar) Fluid inlet 1/2 npt(m) Fluid outlet 1/2 npt(f) 244601 Grease/Paint Flow rate 0.2-1 gpm (0.76-3.8 lpm) Viscosity range 20-5000 cps Accuracy + 3% on dispenses over 12 cc Resolution 0.119 cc/pulse Maximum Working Pressure 3000 psi (21 MPa, 207 bar) Maximum Air Pressure 120 psi (0.8 MPa, 8 bar) Fluid inlet 1/4 npt(f) Fluid outlet 3/8 npt(m) Air inlet 1/4 npt(f)
Technical Data

246837 Grease/Paint Flow rate 01-.5 gpm (.038-1.9 lpm) Viscosity range 20-3000 cps Accuracy + 1.5% on dispenses over 12 cc Resolution 061 cc/pulse Maximum Working Pressure 3000 psi ( 21 MPa, 207 bar) Maximum Air Pressure 120 psi (0.8 MPa, 8 bar) Fluid inlet 1/4 npt(f) Fluid outlet 3/8 npt(f) Air inlet 1/4 npt(f) 246838 Meter-less (flow meter supplied by user)
Flow rate (TBD) User supplied Viscosity range (TBD) User supplied Accuracy (TBD) User supplied Resolution (TBD) User supplied Maximum Working Pressure 3000 psi (21 MPa, 207bar) Maximum Air Pressure 120 psi (0.8 MPa, 8 bar) Fluid inlet (TBD) User supplied Fluid outlet 1/4 npt(f) Air inlet 1/4 npt(f) 246839 Grease/Paint/Sealants Flow rate 013-6 gpm (.05-22 lpm) Viscosity range 30-1,000,000 cps Accuracy + 5% on dispenses over 12 cc Resolution 0.286 cc/pulse Maximum Working Pressure 3000 psi (21 MPa, 207 bar) Maximum Air Pressure 120 psi (0.8 MPa, 8 bar) Fluid inlet 3/4 npt(f) Fluid outlet 3/8 npt(m) Air inlet 1/4 npt(f)
Technical Data

244599 aluminum, carbon steel, bronze, buna-N, stainless steel 244600 brass, stainless steel, polyimide, polypropylene, EPDM o-ring, aluminum, buna-N, carbon steel 244601 303, 400 series, and 416 stainless steel, Tungsten carbide, PTFE, carbon steel, chrome, nylon, UHMWPE, leather ProDispense™ and EasyKey™ are trademarks of Graco Inc.
514037 Printer paper roll
198669 Printer cable 50 ft. (15.24 m)
197902 Paint Shield For display screen, package of 10
198456 Remote Station Extension Cable 20 ft. (6.1 m)
245248 Software Upgrade Kit for Main PCB Includes main PCB chip with software upgrade, chip extractor, and grounding strap.
244840 Software Upgrade Kit for Display PCB Includes display PCB chip, chip extractor, and grounding strap.
Accessories and Kits · 239873 Printer kit

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor, or call to identify the nearest distributor: 1-800-328-0211 Toll Free, 612-623-6921, 612-378-3505 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 309301
Copyright 2001, Graco Inc. is registered to ISO 9001
www.graco.com Revised 11/2009
Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| Out of Tolerance Alarm | Dispense is under or over tolerance limit set for the fluid. | Run screen shows tolerance difference for last dispense. Use the value to determine whether you should: • Increase the tolerance value • Model 244601 only — increase fluid flow by further opening the dispense valve (turn the t-handle clockwise). • Increase or decrease fluid flow rate of the fluid supply. | p.36 |
| Dispense Timeout Alarm | The dispense did not complete within set Dispense Timeout value. | Check the following: • Fluid supply container is not empty. • Fluid supply equipment is not faulty. • Fluid flow rate is sufficient. • Timeout value is too low and needs increase. • Fluid line is not clogged. • Solenoids are operating. • Model 244601 only — solenoid is receiv- ing air and dispense valve is open. • Cables are properly connected. • Meters are operating and communicating with controller. • Dispense valves are operating. Service equipment as needed. | p.36 |
| Invalid K-factor Alarm | Meter K-factor is set to zero (00.000). | Set valid meter K-factor (page 27). | p.36 |
| Memory Failure Alarm | The system is not configured. | Enter setup values (page 25). | p.36 |
| Memory Failure Alarm | The memory is corrupt. | Replace flash EPROM. | p.36 |
| No display | No power | Turn on or reconnect power. | p.36 |
| No display | Faulty cable(s) | Replace cable(s). | p.36 |
| No display | Blown fuse(s) | Replace fuse(s). | p.36 |