ST AINLESS STEEL, W A TERBASE COMP A TIBLE Fluid Pressure Regulators Used to regulate fluid pressure in low pressure systems only . Fluid Flow up to 3 GPM (1 1 liters/min) Instructions–Parts List 307212ZAC EN Important Safety Instructions Read all warnings and instructions in this manual.
2 307212 T able of Contents Models 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . .
3 307212 Models Spring Operated Fluid Regulators Part No. Series Maximum Fluid Inlet Pressure, psi (kPa, bar) Regulated Pressure Range, psi (kPa, bar) Gauge Gauge Pressure Range, psi (kPa, bar) 214895 H 250 (1800, 18) 5–100 (34–700, 0.3–7) No n/a 214706 H 250 (1800, 18) 5–100 (34–700, 0.
4 307212 Notes.
5 307212 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury .
6 307212 Installation FLUID SUPPL Y INLET BALL V A L VE OUTLET BALL V A L VE PIPE NIPPLES BACK PRESSURE VA LV E FLUID RETURN AIR FIL T ER & REGULA TOR Spring Operated Installation Models 214895, 2.
7 307212 Installation Fluid pressure regulators are used for accurate, posi- tive control of the fluid pressure to spray guns, dis- pensing valves or atomizing heads. Regulators installed at circulating line take-offs or pumps are used to reduce main line pressure and maintain the desired fluid pressure to the spray gun or atomizing head.
8 307212 Operation CAUTION The new system must be cleaned and tested thoroughly before admitting fluid to the regulator to avoid contaminants clogging or damaging the regulator . Always use the lowest possible air and fluid pressures for your application.
9 307212 Operation 7. Adjust the fluid regulator to the desired setting. a. Spring Operated Regulators Only (see Fig. 3). The regulator can be adjusted in two ways: Using the male end (B) of the regulator key (24), turn the socket–head adjustment screw (19) fully clockwise .
10 307212 Notes.
11 307212 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to Relieve the Pressure .
12 307212 Service Service of the Air Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s air inlet.
13 307212 Service Models 214980 (shown) & 244375 29 10 13 23 7 1 17 22 26 18 9 15 16 4 20 40 6 21 3 NOTE: Numbers indicate tightening sequence. T ighten evenly to 7–10 in-lb (0.8–1.1 N m), then retorque to 125 in-lb (14 N m) three times, consecu- tively , to compensate for diaphragm relaxation.
14 307212 Service Service of the Spring Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s fluid inlet.
15 307212 Service 10 Models 217314 and 221 1 18 Models 214895, 214706, 255374, and 24A082 21 12 13 22 25 17 26 3 15 16 23 40 6 9 18 4 20 1 7 10 21 12 13 22 17 26 3 15 16 23 40 6 9 18 4 20 1 5 2 4 6 1 3 BOTTOM VIEW PET NOTE: Numbers indicate tightening sequence.
16 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 28 23 4* *15 *16 *20 40* 1 6 18 26* 22* 17 13 Model 214895, Series H Without gauge. Includes items 1–26, 40 Model 214706, Series H With gauge. Includes items 1–40 Model 214706 only Ref No.
17 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 23 4* *15 *16 *20 40* 1 6 18 26* 22* 17 13 TI0037 Model 255374, Series A Model 24A082, Series A ISO pitch thread inlet and outlet (n ot compatible with US standard pitch – fluid housing coated with PTFE based polymer) Includes items 1–40 Ref No.
18 307212 Parts 24 7 19 14 12 11 5 10 *21 *3 *9 27 28 23 4* *15 *16 *20 40* 1 6 32 18 26* 25* 17 13 Model 221 1 18 only Model 217314, Series F With gauge. Includes items 1–32, 40 Model 221 1 18, Series E Without gauge.
19 307212 Parts Model 214980 Series F Includes items 1–40 *9 7 29 10 *21 *3 27 28 *15 *16 *20 40* 4* 23 1 18 26* 22* 17 13 6 Ref No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 100644 SCREW , soc hd cap; 0.
20 307212 Parts TI1697A Model 244375 Series B Includes items 1–41 *9 7 10 *21 *3 *15 *16 *20 40* 4* 23 1 18 26* *22 13 6 29 17 19 41 Ref No. Part No. Description Qty . Ref. No. Part No. Descri ption Qty . 1 100644 SCREW , soc hd cap; 0.
21 307212 Dimensions Model 244375: 3” (76.2 mm) All Other Models: 4.94” (125.5 mm) 1.76” (44.7 mm) 1.8” (46 mm) 3/8 npsm female INLET 3.65” (93 mm) DIA.
22 307212 T echnical Data Category Data Maximum Fluid Inlet Pressure 250 psi (1.8 MPa, 18 bar) Regulated Fluid Pressure Range Models 217314 & 221 1 18: 20–160 psi (0.15–1.1 MPa, 1.5–1 1 bar) Models 214706, 214895, 244375, 255374, & 24A082: 5–100 psi (30–700 kPa, 0.
23 307212 Performance Chart 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 0123 45 FLUID FLOW kPa bar p si gpm liters/min 0 10 20 30 40 50 60 70 80 90 100 0123 45 3.
24 307212 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Een belangrijk punt na aankoop van elk apparaat Graco 307212ZAC (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graco 307212ZAC heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graco 307212ZAC vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graco 307212ZAC leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graco 307212ZAC krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graco 307212ZAC bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graco 307212ZAC kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graco 307212ZAC . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.