NL
Graco logo
Officiële handleiding

Graco 309518P

48 pagina's·3.3 MB·Wasmachine·PDF·EN
Graco 309518P
Inhoudsopgave 35 secties Xtreme Mix Models · Manual Conventions · Related Manuals · Warnings · … TonenVerbergen
Page 1 of the Graco 309518P user manual — ENG
Pagina 1 · klik om te vergroten
Pagina 1

Repair

Xtreme Mix ™

ENG

Plural Component Proportioner For spraying two-component protective coatings. Not approved for use in explosive atmospheres.

See page 3 for model information, including maxi- mum working pressure and approvals.

Page 3 of the Graco 309518P user manual — WARNING
Pagina 3 · klik om te vergroten
Pagina 3

Xtreme Mix Models

WARNING

Do not install equipment approved only for non-haz- ardous location in a hazardous area. Substitution of components may impair intrinsic safety. See page 5.

Approved for Non-hazardous Location Xtreme Mix Part No.SeriesPump Part No.Pump DescriptionMaximum Working Pressure psi (MPa, bar)Approvals 233863A24927445:1 King4500 (31, 310) 233864A24927556:1 King5600 (38.6, 386) 233865A24927668:1 King6800 (46.9, 469) 233866A24927780:1 King7250 (50, 500) 233867A24927845:1 Quiet King4500 (31, 310) 233868A24927956:1 Quiet King5600 (38.6, 386) 233869A24928068:1 Quiet King6800 (46.9, 469) 233870A24928180:1 Quiet King7250 (50, 500) *248842A24927668:1 King Remote Mix5000 (34.5, 345)

*Model 248842 is designed for remote feed pumps and a remote mix manifold. It does not include hoppers, mix manifold, hose, or spray gun. Refer to manual 310794 for application layout.

Model 248842 is limited to 5000 psi (34.5 MPa, 345 bar) for use in “quick set” packages where heated hoses, whip hoses, and spray accessories are limited to 5000 psi (34.5 MPa, 345 bar). If all your downstream compo- nents are rated for 7000 psi (48 MPa, 483 bar), you can replace the standard relief valve with relief valve 113498.

Xtreme Mix Models

Page 4 of the Graco 309518P user manual — Related Manuals
Pagina 4 · klik om te vergroten
Pagina 4

Manual Conventions

Note

WARNING

Additional helpful information.

Components A and B

IMPORTANT!

Material suppliers can vary in how they refer to plural component materials.

Be aware that in this manual: Component A refers to resin or major volume. Component B refers to catalyst (curing agent) or minor volume.

Related Manuals

Component Manuals This manual available in following languages:

ManualDescription 309535Xtreme Mix Operation 311762Xtreme Displacement Pump 309347 or 309348King Air Motor King Quiet Air Motor 312145XTR Spray Gun 309524VISCON HP Heater 309525Heated Hose Kit 308981Husky 716 Diaphragm Pump 309615Heater Bracket Kit 309568Remote Manifold Kit 310797Remote Mix Manifold 310794Remote Mix Proportioning Systems 310863Feed and Flush Kits 309827Air Supply Kits
ManualLanguageManualLanguage 309518English309609Italian 309564French309610Finnish 309565Brazilian Portuguese309611Swedish 309566Spanish309612Chinese 309567German309613Korean 309608Greek309614Japanese 310752Dutch310753Norwegian 310777Danish

Manual Conventions · Hazard Symbol

Page 5 of the Graco 309518P user manual — Warnings
Pagina 5 · klik om te vergroten
Pagina 5

Warnings

The following general warnings are related to the safe setup, use, grounding, maintenance, and repair of this equip- ment. Additional more specific warnings may be found throughout the text of this manual where applicable.

Warning FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground equipment and conductive objects in work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a fire extinguisher in the work area. ELECTRIC SHOCK HAZARD Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment. • Connect only to grounded power source. • All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Do not spray without tip guard and trigger guard installed. • Engage trigger lock when not spraying. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
Page 6 of the Graco 309518P user manual — Warnings
Pagina 6 · klik om te vergroten
Pagina 6
Warning EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. • Check equipment daily. Repair or replace worn or damaged parts immediately. • Do not alter or modify equipment. • For professional use only. • Use equipment only for its intended purpose. Call your Graco distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or overbend hoses or use hoses to pull equipment. • Comply with all applicable safety regulations. BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection RECOIL HAZARD Gun may recoil when triggered and cause you to fall and be seriously injured if you are not standing securely.
Page 7 of the Graco 309518P user manual — Pressure Relief Procedure
Pagina 7 · klik om te vergroten
Pagina 7

Pressure Relief Procedure

Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 1 · Pressure Relief Procedure
6. Hold a metal part of the gun firmly to a grounded metal pail. Trigger gun to relieve pressure.
Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 2 · Pressure Relief Procedure

Follow Pressure Relief Procedure when you stop spraying and before cleaning, checking, servicing, or transporting equipment. Read warnings, page 5.

1. Engage trigger lock.
Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 3 · Pressure Relief Procedure
7. Engage trigger lock.
Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 4 · Pressure Relief Procedure
8. Place waste container under sampling valves, then open valves A and B slowly to relieve pressure between pump and metering valve.
Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 5 · Pressure Relief Procedure
3. Close main air shutoff valve on air supply line and on unit. Turn off air regulator.
4. Close fluid sampling and shutoff valves A and B.
Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 6 · Pressure Relief Procedure
9. Close sampling valves A and B.
Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 7 · Pressure Relief Procedure
5. Disengage trigger lock.
Graco 309518P — Pressure Relief Procedure diagram (page 7)
Afb. 8 · Pressure Relief Procedure

Pressure Relief Procedure

Page 8 of the Graco 309518P user manual — WARNING
Pagina 8 · klik om te vergroten
Pagina 8

Proper Lifting of Unit

Proper Lifting of Unit

Graco 309518P — Proper Lifting of Unit diagram (page 8)
Afb. 9 · Proper Lifting of Unit
Graco 309518P — Proper Lifting of Unit diagram (page 8)
Afb. 10 · Proper Lifting of Unit

Follow instructions below to avoid dropping or swing- ing unit or being struck by the cart handle, which can cause serious injury or damage to equipment.

Either remove the cart handle or secure it to the cart before lifting the unit. Connect a bridle swing, hooking an end to each of the Xtreme Mix air motor rings. Hook the center ring on a hoist. See FIG. 1. Carefully lift the Xtreme Mix unit; make sure it balances evenly.

Grounding

WARNING

Read warnings, page 5.

If the Xtreme Mix ground wire clamp (G) is disconnected during repair, be sure to reconnect it to a true earth ground before starting operation.

Graco 309518P — WARNING diagram (page 8)
Afb. 11
Page 9 of the Graco 309518P user manual — Air Filters
Pagina 9 · klik om te vergroten
Pagina 9

Shutdown

Maintenance

Follow this procedure before prolonged shutdown or servicing equipment.

Metering Valve

  • Fill metering valves A and B packing nuts (627) with throat seal liquid (TSL) and tighten 1/4 turn after nut contacts packings; about 145-155 in/lbs (16-18 N
  • m). Check packing nut tightness after first hour of operation, again after 24 hours, then check as needed (when TSL discolors or seeps over packing nut). Also check tightness whenever unit is transported.

If your system includes heaters and heated hose, make sure they are turned off and cool before flushing.

1. Follow Pressure Relief Procedure , page 7. Engage trigger lock, turn off air regulator, and close main air shutoff valve. Remove spray tip.
Graco 309518P — Metering Valve diagram (page 9)
Afb. 12 · Metering Valve
  • Recommend that you replace metering valve packings every other time that pump packings are replaced.
Graco 309518P — Metering Valve diagram (page 9)
Afb. 13 · Metering Valve
2. Follow Full System Flushing procedure in the Xtreme Mix Operation manual.
3. Follow Pressure Relief Procedure , page 7. Engage trigger lock.
4. Before prolonged shutdown: cap fluid outlets to keep solvent in the lines. Fill pump A and B packing nuts with throat seal liquid (TSL); follow instructions in pump manual.

Pump

See pump manual.

Turbine Alternator

Replace bearings every 2000 hours. See page 20.

Air Filters

Check daily. Drain and clean as necessary. See page 16.

Shutdown

Page 10 of the Graco 309518P user manual — Pump Test
Pagina 10 · klik om te vergroten
Pagina 10

Pump Test

Follow this procedure the first time system is operated (after flushing and priming) and whenever you need to check whether pumps are on ratio.

c. Press Start . Pump A light comes on.

d. Slowly open and adjust sampling valve A to achieve desired flow. The pump stops automati- cally when dispense is complete. Pump A light turns off, Pump B light comes on.

The following table shows the volume dispensed during the pump test, based on your pump ratio. Dispense into a container with adequate graduations.

Graco 309518P — Pump Test diagram (page 10)
Afb. 14 · Pump Test
Graco 309518P — Pump Test diagram (page 10)
Afb. 15 · Pump Test
45:1750 cc 56:1660 cc 68:1540 cc 80:1435 cc
1. Turn knob to pump test . Turn off air regulator. Open main air shutoff valve. Adjust air pressure to 50 psi (0.35 MPa, 3.5 bar).
Graco 309518P — Pump Test diagram (page 10)
Afb. 16 · Pump Test
3. Close sampling valve A.
Graco 309518P — Pump Test diagram (page 10)
Afb. 17 · Pump Test
2. Dispense fluid A:

a. Close fluid shutoff valves and sampling valves A and B.

4. Dispense fluid B as follows:

b. Place a clean 1 quart (1000 cc) container under sampling valve A.

sam b. Slow achi cally turnpling valve B. ly open and adjust eve desired flow. Th when dispense is c s off.sampling valve B to e pump stops automatiomplete. Pump B light Bb. Open a.
Graco 309518P — Pump Test diagram (page 10)
Afb. 18 · Pump Test
Graco 309518P — Pump Test diagram (page 10)
Afb. 19 · Pump Test

Pump Test

Page 11 of the Graco 309518P user manual — B
Pagina 11 · klik om te vergroten
Pagina 11
5. Close sampling valve B.

B

6. Compare fluid amounts in the containers; they should be equal. Repeat test if fluids are not equal. If problem still persists, see Troubleshooting , page 12.

Pump Test · Close

Page 12 of the Graco 309518P user manual — WARNING
Pagina 12 · klik om te vergroten
Pagina 12

Troubleshooting

WARNING

If an error code displays, see page 15.

Read warnings, page 5.

ProblemCauseSolution Display not lit. No electric power.Air valve not turned on.Turn on main air valve to system. Air supply pressure too low.Increase pressure to 50 psi (0.35 MPa, 3.5 bar) or greater. Air supply filters plugged.Clean filter bowls; replace filter elements. Page 16. Turbine air regulator set too low.Adjust to proper setting. Turbine alternator failure.Repair or replace turbine. Page 20. Power supply not connected to main board.Check power connections to main board. See Electrical Schematic, page 28. Main board not connected to display board.Check electrical connections between display and main board. See Electrical Schematic, page 28. Display board failure.Replace display board. Page 18. Pumps do not run.Knob set to cycle counterSet knob to desired setting. Air pressure to pumps too lowIncrease pressure to 50 psi (0.35 MPa, 3.5 bar) or greater. Air pilot lines are obstructedCheck pilot lines for kinks or pinches. Solenoid valve stuck.Actuate solenoid manually, if it does not operate, replace solenoid. Page 21. Air pilot valve(s) to motor stuck.Replace valve(s). Page 22. Metering valve(s) not opening.Service or replace valve(s). Page 24. Pump test volume is not correct.Air pressure to pumps too lowIncrease pressure to 50 psi (0.35 MPa, 3.5 bar) or greater. Sensors not functioning properly.Check position of sensors. See page 27. Check board calibration and recalibrate if necessary. See page 19. Replace sensors. Page 27. Pump cavitating excessively.Check for air in lines caused by loose fitting or use of agitator. Material too viscous. Use heater.

Troubleshooting

Page 13 of the Graco 309518P user manual — Problem Cause Solution
Pagina 13 · klik om te vergroten
Pagina 13

Problem Cause Solution

Paint does not cure consistently. Ratio not set correctly. Check that correct ratio is set and set by volume. See Xtreme Mix Operation man- ual.

Material not mixing correctly. Test pump. Page 10.

Make sure mixer is clean; flush as needed. See Xtreme Mix Operation man- ual.

Pump not operating correctly. Observe whether pumps are loading and checking correctly, if not, clean and repair pump. See pump manual.

Poor spray pattern. Fluid pressure too low. Increase pump pressure.

Spray tip dirty or worn. Relieve pressure. Clean or replace tip. Follow gun manual instructions.

Fluid A or B filters plugged. Clean filters. See pump manual.

Mixer or hoses partially plugged or too restrictive.

Inspect parts for cured material. Clean or replace, or use larger hoses and mixer.

System runs erratically. Air filter(s) clogged. Replace elements. Clean. Replace element(s). See page 16.

Air supply hoses undersized. Replace hoses with appropriate size.

Air compressor undersized. Use larger air compressor.

Air supply pressure tank undersized. Use larger pressure tank.

Air supply relief valve opens. Turbine air regulator set too high. Lower setting to 23-25 psi (172-241 kPa, 1.7-2.4 bar).

Turbine alternator makes high-pitched whining noise.

Turbine bearings worn. (Setting turbine air regulator too high, wears bearings.)

Replace bearings. Page 20.

Display shows 88888 or unit reboots unexpectedly.

Turbine is not supplying enough power to board.

Increase turbine regulator setting to 23-25 psi (172-241 kPa, 1.7-2.4 bar).

Check turbine and electrical control exhaust air for restrictions.

Replace turbine bearings. Page 20.

Xtreme Mix does not start when start but- ton is pressed.

Faulty start switch or wire harness. Check start switch and wiring harness continuity; switch is normally open circuit. See Electrical Schematic, page 28.

Faulty stop switch or wiring harness. Check stop switch and wiring harness continuity; stop switch is normally closed circuit. See Electrical Schematic, page 28.

Bad I/O port on main board. Replace board. Page 17.

Fluid valves leaking. Loose or worn packings. Tighten packing nut. If leak continues, replace packings. Page 24.

Troubleshooting

Page 14 of the Graco 309518P user manual — B
Pagina 14 · klik om te vergroten
Pagina 14

Problem Cause Solution

Flow rate too low. Inadequate air supply. Use larger CFM compressor.

Air pressure to pumps too low. Increase pressure.

Fluid A or B filters plugged. Clean filters. See pump manual.

Spray tip too small. Relieve pressure. Install larger tip. Follow gun manual instructions.

Mixer or hoses partially plugged or too restrictive.

Inspect parts for cured material. Clean or replace, or use larger hoses and mixer.

Pump stops after 12 cycles. Knob is set to Run pump A or B

A

Turn knob to spray if spraying mate- rial.

B

independently.

Xtreme Mix makes chirping noise every 60 seconds. Knob is set to Run pump A or B

A

Turn knob to spray if spraying mate- rial.

independently.

B

Material too heavy to siphon or gravity feed.

Change material feed/supply method.

Troubleshooting

Page 15 of the Graco 309518P user manual — Code Alarm Active Problem Cause
Pagina 15 · klik om te vergroten
Pagina 15

Alarms

  • An alarm condition will shutdown the equipment.
  • A chirping sound every 60 seconds indicates the unit is set for recirculation mode.

* Indicates error where audible alarm sounds once briefly.

** Indicates error where audible alarm sound pulses.

Code Alarm Active Problem Cause

01 Sensor Error A* Always No signal from pump A sensor. Loose cable, failed sensor or cable. Page 27.

02 Sensor Error B* Always No signal from pump B sensor. Loose cable, failed sensor or cable. Page 27.

03 Controller Error* Always Loss of communication between main and display boards.

Loose cable, failed board. Page 17.

04 Pump Runaway A** Spray

Pump running too fast.

Empty fluid reservoir(s).

05 Pump Runaway B**

This alarm is not active when pumps are run independently.

Clogged fluid filter.

Hose rupture after mix manifold.

Sampling valve open too far.

Excessive cavitation.

06 Pump Error A** Spray

Pump does not stall after top change over.

Foot valve leak.

07 Pump Error B**

Air in lines caused by loose fitting or use of agitator.

Pump cavitating excessively.

Empty fluid reservoir(s).

08 Sensor Code Error Always Software boot, sensor values reverted to default.

Sensor value data corrupt; board needs replacement and /or recalibra- tion. Page 17-19.

09 Metering Error A** Spray A dose too great. Metering valve A leak. Page 24.

Empty B fluid reservoir.

10 Metering Error B** Spray B dose too great. Metering valve B leak. Page 24.

Empty A fluid reservoir.

11 Sensor Reading Low A* Always Pump stroke travels beyond sensor range at bottom change over.

Sensor or bracket loose. Page 27.

Sensor magnet dirty. 12 Sensor Reading Low B*

13 Sensor Reading High A* Always Pump stroke travels beyond sensor range at top change over.

Sensor or bracket loose. Page 27.

Sensor magnet dirty. 14 Sensor Reading High B*

15 Piston packing/ball A* Test Pump does not completely stall in up stroke.

Piston packing or ball check failure.

16 Piston packing/ball B*

17 Inlet Ball A* Test Pump does not completely stall in down- stroke.

Foot valve ball check failure.

18 Inlet Ball B*

19 Metering Valve A* Test Pump does not completely stall in both up and down strokes.

Throat packing or metering valve fail- ure. Page 24. 20 Metering Valve B*

Show 6 more labels / short text on this page
Alarms · Startup Errors · Operating Errors · Test Batch · Test Batch · Testing Error
Page 16 of the Graco 309518P user manual — Air Manifold Filter
Pagina 16 · klik om te vergroten
Pagina 16

Repair

Follow Shutdown procedure, page 9, if service time may exceed pot life time, before servicing fluid compo- nents, and before transporting equipment to a service area.

3. Unscrew filter bowl. F IG . 4.
Graco 309518P — Repair diagram (page 16)
Afb. 20 · Repair

WARNING

Read warnings, page 5.

Replacing Air Filter Element

4. Remove and replace element.

There are 2 air filters on the unit: the 5 micron air mani- fold filter (518) and 40 micron pump air filter (8). Check filters daily and replace element as needed.

5. Screw filter bowl on securely.

Pump Air Filter

WARNING

2. Unscrew filter bowl. F IG . 5.
Graco 309518P — Pump Air Filter diagram (page 16)
Afb. 21 · Pump Air Filter

Removing the bowl of a pressurized air filter could cause serious injury. Do not service air filter until air line is depressurized.

Both Filters

1. Close main air shutoff valve on air supply line and on unit. Depressurize air line.

Air Manifold Filter

3. Unscrew plate.
2. Remove air manifold cover (42). F IG . 3.
4. Remove and replace element. F IG . 6.
Graco 309518P — Air Manifold Filter diagram (page 16)
Afb. 22 · Air Manifold Filter
5. Reassemble.

Repair

Page 17 of the Graco 309518P user manual — Software Upgrades
Pagina 17 · klik om te vergroten
Pagina 17

User Interface

Graco 309518P — User Interface diagram (page 17)
Afb. 23 · User Interface

Removing Cover

1. Close main air shutoff valve on air supply line and on unit.
2. Remove air manifold cover (42). F IG . 3, page 16.
3. Remove four nuts (32) and open user interface cover (4). F IG . 7–F IG . 8.
Graco 309518P — Removing Cover diagram (page 17)
Afb. 24 · Removing Cover
3. Install new chip (beveled corner down).
4. Reassemble.
5. Recalibrate main circuit board. See page 19.

Replacing Main Circuit Board

Graco 309518P — Replacing Main Circuit Board diagram (page 17)
Afb. 25 · Replacing Main Circuit Board
1. Remove User Interface cover. See above.
2. Disconnect all wire connectors from board (301). F IG . 10.
3. Remove four screws (302) and replace board (301).
4. Reassemble. Refer to Electrical Schematic , page 28.
5. Recalibrate main circuit board. See page 19.
4. To completely remove cover (4), disconnect ground wire (315), wires (416 and 406) from main board (301). See F IG . 8 and Electrical Schematic , page 28.
Graco 309518P — Replacing Main Circuit Board diagram (page 17)
Afb. 26 · Replacing Main Circuit Board

Software Upgrades

1. Remove User Interface cover. See above.
2. Use a chip remover (D) to remove software chip (C). F IG . 9.

Repair

Page 18 of the Graco 309518P user manual — B
Pagina 18 · klik om te vergroten
Pagina 18

Replacing Display Circuit Board

1. Remove User Interface cover. See page 17.

Ref. 416

2. Disconnect wires from display board (410). F IG . 11.
3. Remove two screws (411).
4. Remove setscrew (B) from knob (405) and remove knob assembly.
5. Remove and replace display board (410).
6. Reassemble. Refer to Electrical Schematic , page 28.

B

Align knob to allow for turning to all 6 settings. 1

Repair · 416 406 · Back View

Page 19 of the Graco 309518P user manual — B
Pagina 19 · klik om te vergroten
Pagina 19

Recalibrate Circuit Board

Follow this procedure whenever the main circuit board, software, or sensor is replaced, or when Alarm 8 occurs (refer to page 15).

1. Note calibration value on pump A sensor. Refer to F IG . 23, page 27.
2. Open main air valve to start unit.
3. Turn knob to pump A . F IG . 12. Hold down

A

Stop button about 5 seconds. The default cali- bration (number between 85000 - 95000) displays.

4. Use key (X) to change default to calibration value noted previously.
5. Note calibration value on pump B sensor.
6. Turn knob to pump B . Hold down Stop button about 5 seconds. The default calibration displays.

B

7. Use key (X) to change default to calibration value noted previously.
Graco 309518P — B diagram (page 19)
Afb. 27

If data download is used, set date and time after calibrating, using Xtreme Mix software.

Repair

Page 20 of the Graco 309518P user manual — Alternator Repair
Pagina 20 · klik om te vergroten
Pagina 20

Pneumatic Control

Graco 309518P — Pneumatic Control diagram (page 20)
Afb. 28 · Pneumatic Control

Alternator Repair

Turbine Alternator Repair Kit 223688 is available to replace turbine bearings.

1. Remove User Interface cover. See page 17.
Graco 309518P — Alternator Repair diagram (page 20)
Afb. 29 · Alternator Repair
Graco 309518P — Alternator Repair diagram (page 20)
Afb. 30 · Alternator Repair
2. Disconnect power supply wires (P). F IG . 13.
3. Disconnect two air lines (310) from alternator (304). F IG . 14.
4. Remove top nut (305) and loosen bottom nut. Slide alternator up and off bottom nut.
5. Remove four screws (304d) to separate alternator housings. F IG . 15.
6. Disconnect turbine (304e) from board (A). Follow instructions in turbine kit manual 308034 to remove and repair turbine.
7. Replace gasket (304a) if damaged. Place between housings before securing with screws (304d).
8. Reassemble. Refer to Electrical Schematic , page 28.
  • Lightly lubricate turbine o-ring before installing turbine in housing.
  • Connect alternator red wire to + side and black wire to – side of main circuit board.
  • Connect turbine to 3-pin connector on main circuit board.

Repair · 304d

Page 21 of the Graco 309518P user manual — S
Pagina 21 · klik om te vergroten
Pagina 21

Replacing Solenoids

3. Disconnect supply and exhaust air lines (310).

Follow this procedure to replace a single solenoid.

4. Disconnect solenoid wires 12 position Phoenix connector (306r) from main board. F IG . 13, page 20.
1. Remove User Interface cover. See page 17.
5. Remove solenoid module (306) with regulator (306e). F IG . 16.
2. Disconnect two solenoid wires (V) from main board. F IG . 16.
6. Unscrew and replace regulator (306e).
3. Remove two screws (S).
7. Reassemble. Refer to Electrical Schematic , page 28.
4. Remove and replace solenoid (306b).

From left to right, solenoid functions are as follows:

Make sure gaskets (306j, 306k) are in place when reinstalling solenoid module.

  • Metering valve A
  • Metering valve B
  • Pump A
  • Pump B
8. Set regulator to 24 psi (160 kPa, 1.6 bar).

Replacing Alarm

5. Reassemble. Solenoid wires are polarized (red +, black –). Refer to Electrical Schematic , page 28.
1. Remove User Interface cover. See page 17.

Replacing Alternator Regulator

2. Disconnect alarm wires from main board.
3. Unscrew alarm (313) and replace. F IG . 16.
1. Remove User Interface cover. See page 17.
2. Remove two screws (309). F IG . 16.
4. Reassemble. Refer to Electrical Schematic , page 28.
Graco 309518P — Replacing Alternator Regulator diagram (page 21)
Afb. 31 · Replacing Alternator Regulator

S

Set regulator pressure to 24 psi (160 kPa, 16 bar) 1

Show 4 more labels / short text on this page
Repair · 306k · 306e · 306j
Page 22 of the Graco 309518P user manual — R
Pagina 22 · klik om te vergroten
Pagina 22

Pump Air Manifold

1. Close main air shutoff valve on air supply line and on unit.
2. Pull off regulator knob (R). F IG . 17.
3. Remove two screws (44).
4. Disconnect two hoses (515) from pump motors.

R

5. Replace parts as needed. See page 40.
6. Reassemble.

Repair

Page 23 of the Graco 309518P user manual — Sampling Valve
Pagina 23 · klik om te vergroten
Pagina 23

Sampling Valve

Graco 309518P — Sampling Valve diagram (page 23)
Afb. 32 · Sampling Valve
1. Follow Pressure Relief Procedure , page 7.
2. Unscrew sampling valve assembly (83) from metering valve (601).
3. Unscrew seat (83c).
4. Remove o-rings (83f), ball (83d), seat (83g), and gasket (83h).
5. Replace parts as needed and reassemble.
Graco 309518P — Sampling Valve diagram (page 23)
Afb. 33 · Sampling Valve

606 (side A) 611 (side B)

Apply anaerobic sealant. Torque to 130-140 in-lbs (15-16 N•m)

Repair

Page 24 of the Graco 309518P user manual — Removing Metering Valve
Pagina 24 · klik om te vergroten
Pagina 24

Metering Valve/Manifold Assembly

Servicing Metering Valve

Follow this procedure to replace packings. Reference numbers with * are included in repair kit 234098. Refer- ence numbers with † are included in repair kit 234131.

Graco 309518P — Servicing Metering Valve diagram (page 24)
Afb. 34 · Servicing Metering Valve
1. Remove metering valve.
2. Remove two locknuts (636). F IG . 20.
3. Remove packing nut (627).

Removing Assembly

4. Remove inlet housing (628).
1. Follow Pressure Relief Procedure , page 7.
5. Unscrew needle (630*) from piston rod (625).
2. Disconnect top and bottom black air tubes.
6. Remove packings (637*, 638, 639*). Inspect needle (630*) and replace if worn.
3. Unscrew fluid tube.
4. Remove nuts (26), screws (27, 48) and lockwashers (25). F IG . 19.

If piston valve packings need replacement:

7. Unscrew cap (622).
5. Remove metering valve manifold (6).
8. Unscrew locknut (631).

Removing Metering Valve

9. Remove piston (623) and replace o-rings (632*†, 633*†, 634*†).
1. Remove Metering Valve/Manifold Assembly .
10. Replace piston rod o-ring (643*†) if damaged.
2. Unscrew metering valve (601) from shutoff valve (606 or 611).
11. Reassemble.
3. If necessary, remove and repair or replace shutoff valve (606 or 611). See manual 306861.
Graco 309518P — Removing Metering Valve diagram (page 24)
Afb. 35 · Removing Metering Valve

Repair

Page 25 of the Graco 309518P user manual — Metering Valve/Manifold Assembly
Pagina 25 · klik om te vergroten
Pagina 25
Graco 309518P — Metering Valve/Manifold Assembly diagram (page 25)
Afb. 36 · Metering Valve/Manifold Assembly
1. Apply pipe sealant to non-swiveling pipe threads. 2. Apply lubricant to threads, o-rings, and seals.

Clean needle (630) and packing cavity before reinstalling packings (637*, 638, 639*). Lubricate packings and install with lips facing up toward packing nut (627) in order shown.

Apply medium anaerobic adhesive. Thread to bottom.

Whenever the seat housing (646) is removed, replace the o-rings (645).

Torque to 5-7 ft/lbs (7-9 N•m).

Torque to 30-40 ft/lbs (41-54 N•m).

Inspect reversible seat for damage. If one side is worn, reverse seat.

Tighten packing nut 1/4 turn after nut bottoms out; 145-155 in/lbs (16-18 N•m). Check packing nut tightness about once a month. Keep packing nut filled with TSL.

Lubricate and press piston evenly into cylinder.

Show 6 more labels / short text on this page
Repair · *† 634 · *† 632 · *† 633 · † 635 · *† 643
Page 26 of the Graco 309518P user manual — Servicing Fluid Manifold 248843
Pagina 26 · klik om te vergroten
Pagina 26

Servicing Fluid Manifold 245833

Follow this procedure to replace packings. Reference numbers with * are included in repair kit 234100.

1. Remove metering valve. See page 24.
2. Unscrew plug (661).
3. Remove and replace o-rings (662*, 663*, 665*), seat (664*), ball (666*), and spring (667*).

Servicing Fluid Manifold 248843

4. Reassemble.

There are no serviceable parts on manifold 248843.

*663 *665 *664 *665 *666 *667

Manifold 245833 1. Apply pipe sealant to non-swiveling pipe threads. 2. Apply lubricant to threads, o-rings, and seals.

Show 5 more labels / short text on this page
Repair · 669 676 · 675 674 665 · 670 668 · *662
Page 27 of the Graco 309518P user manual — Displacement Pump
Pagina 27 · klik om te vergroten
Pagina 27
Graco 309518P — Sensor diagram (page 27)
Afb. 37 · Sensor

Reference numbers with * are included in repair kit 246345. Reference numbers with † are included in repair kit 246344.

1. Close main air shutoff valve on air supply line and unit. F IG . 22.

P L U R A L C O M P O N E N T P R O P O R T I O N E R I

2. Unscrew sensor cap (701†) from nut (712†). F IG . 23.
4. Unscrew fitting (713*), locknut (719*), and cover (702*).

Before assembling cover (702*) to cap (701†), assemble cable (705*) through fitting (713*) and cover (702*), and plug cable into connector on board (703†) and to ground lug.

7. Reassemble and mount sensor. Refer to Electrical Schematic , page 28.

Mount sensor as close to magnet as possible without touching it.

8. Recalibrate main circuit board. See page 19.

Displacement Pump

2. Disconnect 90° swivel (30) from pump lower. Refer to page 32.
Graco 309518P — Displacement Pump diagram (page 27)
Afb. 38 · Displacement Pump
3. Remove pump lower and service as instructed in pump manual 311762.
1. Follow Pressure Relief Procedure , page 7.
Page 28 of the Graco 309518P user manual — Electrical Schematic
Pagina 28 · klik om te vergroten
Pagina 28

Electrical Schematic

Graco 309518P — Electrical Schematic diagram (page 28)
Afb. 39 · Electrical Schematic
KeyBL Black BR Brown BL-G Black with green BL-R Black with red

BL-WBlack with white G Green GNDGround R Red

S Shield W White

Electrical Schematic

Page 29 of the Graco 309518P user manual — Electrical Schematic
Pagina 29 · klik om te vergroten
Pagina 29
Graco 309518P — Electrical Schematic diagram (page 29)
Afb. 40 · Electrical Schematic

Electrical Schematic · 301 304

Page 30 of the Graco 309518P user manual — 12 VDC
Pagina 30 · klik om te vergroten
Pagina 30

Pneumatic Schematic

Turbine / Power Supply

To Pump A Pilot

To Pump B Pilot

5/32 in.

5/32 in.

1/2 in. x 24 in. long

26 psi (79 kPa, 1.8 bar) Relief Valve

12 VDC

12 VDC

12 VDC

3/8 in. tube

Gauge 90/110 psi 0.6/0.8 MPa, 6.2/8 bar)

8 bar) Relief Valve

Air Regulator 110 psi (0.8 MPa,

King Motor A King Motor B

3/4 in. Ball Valve bleed type

Gauge 3/8 in. Air Reg. Auto Drain

5 micron 100 psi (0.7 MPa, 7 bar)

3/4 in. Air Filter Auto Drain

Show 31 more labels / short text on this page
Pneumatic Schematic · A Metering · B Metering · Valve · Valve · 306t 304 · Manifold · A Open · B Open · 3-way valve · 3-way valve · A Close · B Close · Position 2 · Position 3 · 12 VDC Solenoid · Position 1 · Position 4 · Exhaust · Solenoid · Solenoid · Solenoid · Air Supply Air · To Manifold · Alternator Air · Pump A Pilot · Pump B Pilot · 306e · Regulator · Relief Valve · 20 micron
Page 31 of the Graco 309518P user manual — Pneumatic/Sensor Connections
Pagina 31 · klik om te vergroten
Pagina 31

Pneumatic/Sensor Connections

Graco 309518P — Pneumatic/Sensor Connections diagram (page 31)
Afb. 41 · Pneumatic/Sensor Connections

Key: A Pump A Air B Pump B Air C Pump A Pilot Air D Pump B Pilot Air E Air Supply F Metering Valve A - CLOSE G Metering Valve A - OPEN H Metering Valve B- CLOSE J Metering Valve B- OPEN K Sensor A Cable L Sensor B Cable

Pneumatic/Sensor Connections

Page 32 of the Graco 309518P user manual — Parts
Pagina 32 · klik om te vergroten
Pagina 32

Parts

Xtreme Mix Proportioner Parts shown here and page 34 and 36.

Graco 309518P — Parts diagram (page 32)
Afb. 42 · Parts

Parts

Page 33 of the Graco 309518P user manual — Part Number Table
Pagina 33 · klik om te vergroten
Pagina 33

Xtreme Mix Proportioner

Refer to page 3 for additional model information.

Part Number Table

Approved for Non-hazardous Location

233863 249274 (45:1) 245824 XTR704 H53850 15B729 113498 15A914 15A915 233864 249275 (56:1) 245824 XTR704 H53850 15B729 113498 15A914 15A915 233865 249276 (68:1) 245824 XTR704 H73850 15B729 113498 15A914 15A915 233866 249277 (80:1) 245824 XTR704 H73850 15B729 116643 15A914 15A915 233867 249278 (45:1) 245824 XTR704 H53850 15B729 113498 15A914 15A915 233868 249279 (56:1) 245824 XTR704 H53850 15B729 113498 15A914 15A915 233869 249280 (68:1) 245824 XTR704 H73850 15B729 113498 15A914 15A915 233870 249281 (80:1) 245824 XTR704 H73850 15B729 116643 15A914 15A915 248842 249276 (68:1) 248843 none none none 108124 15A914 15A915

Show 16 more labels / short text on this page
Parts · Xtreme · Metering · Gun · Hose · Coupling · Relief Valve (79) · Tube · Tube · Mix Pump (2) · Valve (6) · (15) · (20) · (56) · (45) · (46)
Page 34 of the Graco 309518P user manual — 80 124450 CLAMP 2 81 C20490 FITTING 2
Pagina 34 · klik om te vergroten
Pagina 34

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

38 100721 PLUG; 1/4 nptf 1 39 101566 LOCKNUT, not shown 1 40‡ PLUG 1 42 15B281 COVER 1 43 112774 SCREW, 1/4-20 6 44 103196 SCREW, #8-32 x 0.44 in. 6 45 see table, page 33

1 245997 CART 1 2 see table, page 33

PUMP; see manual 311762 for parts

3 245803 PNEUMATIC CONTROL; parts page 37

4 245804 USER INTERFACE; parts page 39 1 5 245802 PUMP AIR MANIFOLD; parts page 40 1

TUBE, pump B 1

46 see table, page 33

TUBE, pump A 1

6 245824 see table, page 33

METERING VALVE MANIFOLD; parts page 41

47 117344 FITTING; 1/2 npt(m) x 5/8 in. (16 mm) tube

248843 see table, page 33

METERING VALVE MANIFOLD; parts page 41; used on model 248842 only

48 100560 SCREW; 3/8-16 UNC x 4.75 in. 1 or 2** 49 158683 ELBOW, 90°; 1/2 npt 2 56* 15B729 see table, page 33

7 245825 SENSOR; parts page 44 2 8* 117628 AIR FILTER; 3/4 npt; 40 micron 1 9 244524 GROUND WIRE, with clamp; not shown

COUPLING 1

57* H72506 HOSE, fluid; nylon; 1/4 in. (6.3 mm)

10* 551390 BEAKER 2 11 15A847 MAGNET HOLDER 2 12‡ 15A814 MAGNET; 2.7 ft. (0.8 m) 2 13 104092 SCREW; 10-24 UNC 4 15* see table, page 33

ID; 1/4 npsm(fbe); 6 ft (1.8 m)

58* 243832 KIT, siphon hose; 1/2 npsm(f) x 1/2 npt; not shown

59* 117525 ELBOW, 90°; 1/2 npt 1 60* 108143 STRAINER; 16 mesh 1 61* C19660 FITTING; 1-1/4 x 1/2 npt; not

SPRAY GUN, see manual 312145 1

16* 234017 FLUID RESERVOIR, blue 2 17 C19041 WASHER 1 18* 214954 AIR HOSE; 3/4 x 1/2 npt; 2.75 ft. (0.84 m); not shown

62 246127 CART HANDLE 1 63 15B161 AXLE 1 64 113362 WHEEL 2 65 113436 RETAINING RING 3 66 15B755 SPACER 2 67 114552 CAP 1 68 154628 WASHER 3 70 054139 TUBE, nylon; 1.5 ft. (0.46 m); 0.5 in. OD; not shown ★

20* H73850 see table, page 33

HOSE, fluid; nylon; 3/8 in. (10 mm) ID; 3/8 npsm(fbe); 50 ft (15.2 m) long

H53850 see table, page 33

HOSE, fluid; nylon; 3/8 in. (10 mm) ID; 3/8 npsm(fbe); 50 ft (15.2 m) long

21* 511352 STATIC MIXER 1 22* 150287 COUPLING; 3/8 npt 1 24 100004 SCREW; 3/8 UNC 8 25 100133 LOCKWASHER †15 26 100131 NUT; 3/8-16 UNC †15 27* 115348 SCREW; 3/8-16 UNC x 2.75 in. 2 28* 15A776 PLATE 1 29 207675 AIR MANIFOLD 1 30* 112580 SWIVEL, 90°; 1.25 npsm 2 31 100016 LOCKWASHER 4 32 100015 NUT; 1/4-20 UNC 4 33* 117366 SHUTOFF VALVE, 3-way; 1/2 npt 2 34‡ C12508 TUBE, nylon; 3/8 in. (9.5 mm) OD;

72 101242 RETAINING RING 2 73 113807 WHEEL 2 74 15A912 AXLE, vertical 1 75 15A913 AXLE, horizontal 1 76 191824 WASHER 4 77 15A892 BEARING, brass 2 78* 234097 FLUID RESERVOIR; green 1 79 113498 see table, page 33

SAFETY RELIEF VALVE; 110 psi (0.8 MPa, 8 bar)

116643 see table, page 33

SAFETY RELIEF VALVE; 90 psi (0.6 MPa, 6.2 bar)

1 ft. (0.3 m); not shown ★

108124 see table, page 33

SAFETY RELIEF VALVE; 75 psi (0.5 MPa, 5.2 bar)

35‡ 054753 TUBE, nylon, black; 0.156 in. (4 mm) OD; 6 ft. (1.8 m); not shown

36 15A845 LABEL, air supply pressure 1 37 100139 PLUG; 1/8 nptf 1

80 124450 CLAMP 2 81 C20490 FITTING 2

Parts · shown · ★

Page 35 of the Graco 309518P user manual — Parts
Pagina 35 · klik om te vergroten
Pagina 35

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

83 245143 SAMPLING VALVE; parts page 41 2 84* 116746 FITTING; 1/8 npt x 1/4 in. (6.4 mm) tube; see page 41

97b 160022 • UNION; 1 in. npt(m) x 1 in. npsm(m)

  • 97c 110878
  • STRAINER; 1 in. 1 97d 118464
  • BALL VALVE; 1 in. 1 97e 202965
  • UNION; 1 in. npt(m) x 3/4 npsm(f)

85* 116750 TUBE, nylon; 5 in. (12.7 cm); parts page 41

86 193185 LABEL, warning 3 87* 15C567 BRACKET, hopper 2 88* 100132 WASHER, flat; not shown 4 90** 116401 ELBOW, 90° 2 97** 249024 STRAINER KIT; 500 psi (3.4 MPa, 34 bar) maximum working pres- sure; includes items 97a-97e

98 100451 COUPLING 1 99 115671 FITTING, (m) 1/8 npt 1 100 054123 TUBE, draining 2ft.

* Not included with Model 248842. ** Included with Model 248842 only. ‡ Not available for order from Graco. ★ Order length needed from distributor.

97a C20490 • NIPPLE, hex; 1 in. npt 2

Graco 309518P — Parts diagram (page 35)
Afb. 43 · Parts
Show 6 more labels / short text on this page
Parts · Hose and Gun · *15 · *56 *21 *22 · 20* · *57
Page 36 of the Graco 309518P user manual — Parts
Pagina 36 · klik om te vergroten
Pagina 36
Graco 309518P — Parts diagram (page 36)
Afb. 44 · Parts

Parts

Page 37 of the Graco 309518P user manual — 306 REF 316 313
Pagina 37 · klik om te vergroten
Pagina 37

Pneumatic Control 245803

Item 3, page 33

Graco 309518P — Pneumatic Control 245803 diagram (page 37)
Afb. 45 · Pneumatic Control 245803

306 REF 316 313

TI2303A

A PUMP

Parts

Page 38 of the Graco 309518P user manual — Pneumatic Control 245803
Pagina 38 · klik om te vergroten
Pagina 38

Pneumatic Control 245803

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

315 15B090 GROUNDING WIRE, door 1 316 15B056 LABEL, air connections 1 317 111307 LOCKWASHER 1 320 118132 LOCKWASHER, terminal 1 321 118129 SPACER, 8-32 UNC x 5 in. (127 mm)

301 245705 CIRCUIT BOARD 1 301a 15C318 FUSE, circuit board 1 302‡ SCREW; 8-32 UNC 4 303‡ COVER 1 304** 245854 ALTERNATOR MODULE; includes items 304a-304e

  • 304a 193154
  • GASKET 1 304b 15A853
  • WIRE HARNESS 1 304c 111225
  • TUBE FITTING; 90° 2 304d 114380
  • SCREW; M5 x 25 4 304e 249254
  • TURBINE ALTERNATOR 1 305‡ LOCKNUT; 8-32 UNC 2 306‡ SOLENOID MODULE, IS; includes items 306a-306t

IS = intrinsically safe

** Alternator bearing repair kit 223688 available.

‡ Not available for order from Graco.

★ Order length needed from distributor.

  • 306a 15A822
  • MANIFOLD 1 306b 117356
  • VALVE, 12 VDC, IS 4 306c 114263
  • FITTING; 1/8 npt x 5/32 in. (4 mm) tube
  • 306d‡
  • NIPPLE; 1/4 npt 1 306e 115243
  • AIR REGULATOR; 1/4 npt 1 306f 115841
  • ELBOW, swivel; 1/4 npt x 3/8 in. (9.5 mm) tube
  • 306g 160701
  • ELBOW, street; 1/8 npt(m x f) 1 306h 108190
  • GAUGE, 1 306j‡
  • GASKET, neoprene 1 306k‡
  • GASKET, neoprene 1 306n‡
  • PLUG, pipe; 1/8-27 ptf 5 306p 114128
  • ELBOW; 1/4 npt x 1/2 in. (13 mm) tube

306q† 112512 • WIRE FERRULE, orange (not shown)

  • 306r 117369
  • CONNECTOR, 12 position 1 306s 150278
  • ADAPTER, 1/4 x 1/8 npt 1 306t 117480
  • SAFETY RELIEF VALVE, 26 psi (179 kPa, 1.8 bar)

307 15A800 GASKET, neoprene 1 309‡ SCREW; M5 x 10 2 310 C12508 TUBE, poly-flo; 3/8 in. OD; 1 ft.

311‡ NUT, KEPS; #10-24 1 312 104029 GROUNDING STUD 1 313 15A849 WIRE HARNESS, alarm 1 314 117442 CONNECTOR, 18 position 1

Parts · ★ · (3 m)

Page 39 of the Graco 309518P user manual — User Interface 245804
Pagina 39 · klik om te vergroten
Pagina 39

User Interface 245804

Item 4, page 33

Graco 309518P — User Interface 245804 diagram (page 39)
Afb. 46 · User Interface 245804

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

414‡ MOUNT 3 415‡ 102478 STRAP 3 416 15A854 WIRE HARNESS, display 1 418‡ WASHER 4 419 107232 SET SCREW 1

401‡ COVER 1 403 15A851 WIRE HARNESS, start/stop 1 404 15A801 GASKET 1 405 15C335 KNOB 1 406 15A850 WIRE HARNESS, data port 1 407 15A852 WIRE HARNESS, key switch 1 409* LABEL, alarm code 1 410 245706 CIRCUIT BOARD 1 411‡ SCREW; 4-40 2 412 15A856 DISPLAY PANEL 1 413‡ 514619 NUT; 4-40 4

‡ Not available for order from Graco.

* Alarm Code Labels Item 409, English provided. To order other languages:

Part No. Languages

15B843 Chinese, Finnish, Portuguese, Greek, Swedish, Italian 15B844 English, Spanish, French, German, Korean, Japanese

Parts

Page 40 of the Graco 309518P user manual — TI2295A
Pagina 40 · klik om te vergroten
Pagina 40

Pump Air Manifold 245802

Item 5, page 33

Ref. No. Part No. Description Qty.

Graco 309518P — Pump Air Manifold 245802 diagram (page 40)
Afb. 47 · Pump Air Manifold 245802

507 117332 REGULATOR 1 508 100840 ELBOW; 1/4 npt 1 510 15A819 MANIFOLD BLOCK 1 511 160032 NIPPLE; 3/4 npt 1 512 117346 SHUTOFF VALVE, vented 1 513 117364 O-RING, nitrile 3 514 108849 SCREW; 1/4-20 UNC 2 515 15B554 HOSE; 3/4 npt; 4 ft. (1.2 m) 2 516 100549 ELBOW, 90°; 3/4 npt 2 517 165198 NIPPLE; 1/4 x 3/8 npt 1 518 119644 FILTER; 3/8 npt; 5 micron 1 519 114316 ELBOW, swivel; 3/8 npt 1 520 114151 ELBOW, swivel; 1/8 npt x 5/32 in. (4 mm) tube

521 100721 PLUG; 1/4-18 nptf 2 522 512912 MUFFLER; 1/2 npt 2 523 100896 BUSHING; 3/4 x 1/2 npt 2 524 113498 SAFETY RELIEF VALVE; 110 psi (0.8 MPa, 8 bar)

525 117443 STANDOFF, aluminum, 8-32 UNC 2 526 240900 HOSE; 3/4 npt; 2.5 ft. (0.76 m) 1 527 158962 ELBOW, 1/8 (m) x 1/4 (f) 1 528 113911 GAUGE, 1/8, air 1

TI2295A

100 psi (0.7 MPa, 7 bar) setting. 1

Ref. No. Part No. Description Qty.

501 C59752 VALVE, 3-way 2 502 108307 ELBOW; 3/4 npt 2 503 101689 PRESSURE GAUGE 2 504 112166 SCREW; 1/4-20 UNC 4 505 15A820 MANIFOLD 1 506 15A821 PLATE, direction 1

Parts

Page 41 of the Graco 309518P user manual — Repair Kit 249406
Pagina 41 · klik om te vergroten
Pagina 41

Metering Valve Manifold 245824 Item 6, page 34

Graco 309518P — Metering Valve Manifold 245824 Item 6, page 34 diagram (page 41)
Afb. 48 · Metering Valve Manifold 245824 Item 6, page 34

Ref. No. Part No. Description Qty.

601 245846 METERING VALVE; parts page 42 2 606 245861 SHUTOFF VALVE; see manual 306861 1

607a 245833 FLUID MANIFOLD; parts page 43 1 611 245860 SHUTOFF VALVE; see manual 306861 1

Metering Valve Manifold 248843 Item 6, page 34

Ref. No. Part No. Description Qty.

601 245846 METERING VALVE; parts page 42 2 606 245861 SHUTOFF VALVE; see manual 306861 1

607b 249406 FLUID MANIFOLD, kit; see right 1 611 245860 SHUTOFF VALVE; see manual 306861 1

Sampling Valve 245143 Item 83, page 35

Ref. No. Part No. Description Qty.

83a 245110 KNOB 1 83b 197681 HOUSING 1 83c 197332 SEAT 1 83d 107536 BALL, carbide 1 83e 110082 RETAINING RING 1 83f 111457 O-RING, PTFE 2 83g 183548 SEAT 1 83h 187060 GASKET 1

* See page 35 for part numbers and descriptions.

Repair Kit 249406

Ref. No. Part No. Description Qty.

610 15E725 FLUID MANIFOLD 1 612 116343 GROUND SCREW 2 613 111307 LOCK WASHER 2 614 101754 PLUG, pipe 2 615 117502 REDUCER; #5 x #8 JIC 1 616 117556 NIPPLE; #8 JIC x 1/2 npt 1 617 117557 NIPPLE; #10 JIC x1/2 npt 1 618 117677 REDUCER, #6 x #10 JIC 1

Parts · 607b

Page 42 of the Graco 309518P user manual — Metering Valve 245846
Pagina 42 · klik om te vergroten
Pagina 42

Metering Valve 245846

Graco 309518P — Metering Valve 245846 diagram (page 42)
Afb. 49 · Metering Valve 245846

Item 601, page 41

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

637*† 117334 V-PACKING, UHMWPE 6 638*† 189901 GLAND, male 1 639*† 117335 V-PACKING, leather 5 643*† 111959 O-RING, buna-n 1 644† 15A830 SEAT 1 645*† 15T260 O-RING, fluoroelastomer 2 646 15A832 SEAT HOUSING 1 647 102637 SCREW; 3/8 UNC-2A 4

621 598140 ELBOW, 1/8 npt(m) x 5/32 in. (4 mm) tube

622‡ 15A840 VALVE CAP 1 623‡ 15A841 PISTON 1 624‡ 15A839 CYLINDER 1 625 15B545 PISTON ROD 1 626 15A834 TIE ROD 2 627 15A835 PACKING NUT 1 628 15A833 INLET HOUSING 1 629▲180233 WARNING LABEL 1 630† 245850 FLUID NEEDLE 1 631 111040 LOCKNUT, nylon; 5/16 UNC-3B 1 632*† 117336 O-RING, nitrile 1 633*† 117370 O-RING, nitrile 1 634*† 117337 O-RING, nitrile 1 635† 109141 SPRING 1 636 102040 LOCKNUT; 1/4 UNC 2

* Parts included in kit 234098. † Parts included in kit 234131.

‡ Not available for order from Graco. ▲ Replacement Warning labels available at no cost.

Show 6 more labels / short text on this page
Parts · *† 634 · *† 632 · *† 633 · † 635 · *† 643
Page 43 of the Graco 309518P user manual — TI2304A
Pagina 43 · klik om te vergroten
Pagina 43

Fluid Manifold 245833

Item 607a, page 41

*663 *665 *664 *665 *666 *667

TI2304A

Ref. No. Part No. Description Qty.

661 15A823 PLUG 2 662* 107098 O-RING, PTFE 2 663* 107313 O-RING, PTFE 2 664* SEAT 2 665* 103341 O-RING, PTFE 5 666* BALL, metallic 2 667* 117333 SPRING 2 668 PLUG; 3/8 npt 4 669 15A825 PIPE, outlet 1 670 192977 PIPE, center 1 671‡ HOUSING 1 674 111307 LOCKWASHER 2 675 116343 GROUND SCREW,; M5 x 0.8 2 676 159239 NIPPLE; 3/8 x 1/2 npt 1

* Parts included in kit 234100.

‡ Not available for order from Graco.

Show 5 more labels / short text on this page
Parts · 669 676 · 675 674 665 · 670 668 · *662
Page 44 of the Graco 309518P user manual — TI2301A
Pagina 44 · klik om te vergroten
Pagina 44

Sensor 245825

Item 7, page 33

Graco 309518P — Sensor 245825 diagram (page 44)
Afb. 50 · Sensor 245825

TI2301A

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

713* 117569 FITTING; 3/8 npt x 5/16 in. conduit 2 714† 154741 O-RING, buna-n 1 715 245831 BRACKET 1 716† 104765 PLUG; 18-27 ptf 1 719* 117586 LOCKNUT; 3/8-18 npt 2 720† C20272 O-RING; fluoroelastomer 1 721* 117582 CONDUIT, 5 ft. (1.5 m); not shown ★

701† 196280 CAP 1 702* 15A818 COVER 1 703† 243500 BOARD 1 704† 115925 SPACER 2 705* 117331 CABLE 1 706† 115917 SENSOR 1 707† 110004 O-RING, PTFE 1 708† 196289 CAP 1 709* 116024 TAB TERMINAL 1 710* 101855 SCREW; 4-24 UNC 1 711* 112546 SCREW; 4-40 taptite 2 712† 15A817 NUT; 1/8 npt 1

* Parts included in kit 246345.

† Parts included in kit 246344.

★ Order length needed from distributor.

Calibration label. 1

Show 11 more labels / short text on this page
Parts · 704† · 703† · 720† · 710* · 709* · 702* · 705* · 719* · 713* · 721*
Page 45 of the Graco 309518P user manual — Technical Data
Pagina 45 · klik om te vergroten
Pagina 45

Technical Data

Mix ratio range 0.0:1-10:1 (in 0.1 increments) Ratio tolerance range +/- 5% Flow rates

Minimum 1 qt./min. (0.95 liter/min.)* Maximum 3 gal./min. (11.4 liter/min.) Fluid viscosity range 200-20,000 cps (heavier viscosities can be mixed with use

of optional heaters, heated hoses, and hardware) Fluid filtration 60 mesh, (238 micron) standard on pump outlets (Filter

assembly not included on models 248831, 248832, 248833, and 248834) Air inlet

3/4 npt(m) 3/4 npt(f) Model 248842: Fluid inlet 3/4 npsm union in 1 in. npt(f) ball valve Maximum fluid working pressure

Model 248842 All Other Models

45:1 4500 psi (31 MPa, 310 bar) 56:1 5600 psi (38.6 MPa, 386 bar) 68:1 6800 psi (46.9 MPa, 469 bar) 68:1 Model 248842 only 5000 psi (34.5 MPa, 345 bar) 80:1 7250 psi (50 MPa, 500 bar) Air supply pressure range 50-110 psi (345-800 kPa, 3.5-8 bar) Model 248842: Maximum fluid feed pressure 500 psi (3.5 MPa, 35 bar)

Maximum air consumption at 100 psi (0.7 MPa, 7 bar) in cfm (m3/min.)

45:1 110 (3.1) 56:1 125 (3.5) 68:1 155 (4.4) 80:1 180 (5.1) Ambient temperature range

Operating 32-130° F (0-54° C) Storage 30-160° F (–1-71° C) Environmental Conditions Rating Indoor/outdoor use

Altitude up to 4000 meters Maximum relative humidity to 99% up to 54° C Pollution degree (11) Installation category (2) Sound pressure 98 dBA at 100 psi (0.7 MPa, 7 bar) Wetted parts

Suction tubes (if used) aluminum Pumps carbon steel, alloy steel, 303, 440 & 17-4ph grades stain-

less steel, zinc and nickel plating, ductile iron, tungsten carbide, PTFE, leather Metering Valves carbon steel, zinc plating, carbide, polyethylene, leather Manifold carbon steel, zinc plating, carbide, 302 stainless steel Mixer stainless steel Spray gun See gun manual

Technical Data

Page 46 of the Graco 309518P user manual — Technical Data
Pagina 46 · klik om te vergroten
Pagina 46

PC Communications RS-232 Dimensions

Cart model (width x height x diameter) 33 in. wide x 64.53 in. high x 44.5 in. deep

(83.8 x 163.9 x 113 cm) Weight (cart, without hose and gun) 625 lbs. (285 kg)

* Minimum flow rate is dependent on the material being sprayed and mixing capability. Test your material for spe- cific flow rate.

Technical Data

Page 47 of the Graco 309518P user manual — Technical Data
Pagina 47 · klik om te vergroten
Pagina 47

Technical Data

Page 48 of the Graco 309518P user manual — GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Pagina 48 · klik om te vergroten
Pagina 48

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211, Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM 309518

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441

Copyright 2002, Graco Inc. is registered to ISO 9001

www.graco.com Revised 01/2011

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Codes weergeven

Foutcodes

Wat de op het display getoonde foutcodes betekenen en hoe u ze wist.

CodeBetekenisOplossing
01Loose cable, failed sensor or cable. Page 27. p.15
02Loose cable, failed sensor or cable. Page 27. p.15
03Loose cable, failed board. Page 17. p.15
04Empty fluid reservoir(s). Clogged fluid filter. Hose rupture after mix manifold. Sampling valve open too far. Excessive cavitation. p.15
06Foot valve leak. Air in lines caused by loose fitting or use of agitator. Empty fluid reservoir(s). p.15
08Sensor value data corrupt; board needs replacement and /or recalibra- tion. Page 17-19. p.15
09Metering valve A leak. Page 24. Empty B fluid reservoir. p.15
10Metering valve B leak. Page 24. Empty A fluid reservoir. p.15
11Sensor or bracket loose. Page 27. Sensor magnet dirty. p.15
13Sensor or bracket loose. Page 27. Sensor magnet dirty. p.15
15Piston packing or ball check failure. p.15
17Foot valve ball check failure. p.15
19Throat packing or metering valve fail- ure. Page 24. p.15
Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
Display not lit. No electric power.Air valve not turned on.Turn on main air valve to system. p.12
Display not lit. No electric power.Air supply pressure too low.Increase pressure to 50 psi (0.35 MPa, 3.5 bar) or greater. p.12
Display not lit. No electric power.Air supply filters plugged.Clean filter bowls; replace filter elements. Page 16. p.12
Display not lit. No electric power.Turbine air regulator set too low.Adjust to proper setting. p.12
Display not lit. No electric power.Turbine alternator failure.Repair or replace turbine. Page 20. p.12
Display not lit. No electric power.Power supply not connected to main board.Check power connections to main board. See Electrical Schematic, page 28. p.12
Display not lit. No electric power.Main board not connected to display board.Check electrical connections between display and main board. See Electrical Schematic, page 28. p.12
Display not lit. No electric power.Display board failure.Replace display board. Page 18. p.12
Pumps do not run.Knob set to cycle counterSet knob to desired setting. p.12
Pumps do not run.Air pressure to pumps too lowIncrease pressure to 50 psi (0.35 MPa, 3.5 bar) or greater. p.12
Pumps do not run.Air pilot lines are obstructedCheck pilot lines for kinks or pinches. p.12
Pumps do not run.Solenoid valve stuck.Actuate solenoid manually, if it does not operate, replace solenoid. Page 21. p.12
Pumps do not run.Air pilot valve(s) to motor stuck.Replace valve(s). Page 22. p.12
Pumps do not run.Metering valve(s) not opening.Service or replace valve(s). Page 24. p.12
Pump test volume is not correct.Air pressure to pumps too lowIncrease pressure to 50 psi (0.35 MPa, 3.5 bar) or greater. p.12
Pump test volume is not correct.Sensors not functioning properly.Check position of sensors. See page 27. Check board calibration and recalibrate if necessary. See page 19. Replace sensors. Page 27. p.12
Pump test volume is not correct.Pump cavitating excessively.Check for air in lines caused by loose fit- ting or use of agitator. Material too viscous. Use heater. p.12
Paint does not cure consistently.Ratio not set correctly.Check that correct ratio is set and set by volume. See Xtreme Mix Operation man- ual. p.13
Paint does not cure consistently.Material not mixing correctly.Test pump. Page 10. Make sure mixer is clean; flush as needed. See Xtreme Mix Operation man- ual. p.13
Paint does not cure consistently.Pump not operating correctly.Observe whether pumps are loading and checking correctly, if not, clean and repair pump. See pump manual. p.13
Poor spray pattern.Fluid pressure too low.Increase pump pressure. p.13
Poor spray pattern.Spray tip dirty or worn.Relieve pressure. Clean or replace tip. Follow gun manual instructions. p.13
Poor spray pattern.Fluid A or B filters plugged.Clean filters. See pump manual. p.13
Poor spray pattern.Mixer or hoses partially plugged or too restrictive.Inspect parts for cured material. Clean or replace, or use larger hoses and mixer. p.13
System runs erratically.Air filter(s) clogged. Replace elements.Clean. Replace element(s). See page 16. p.13
System runs erratically.Air supply hoses undersized.Replace hoses with appropriate size. p.13
System runs erratically.Air compressor undersized.Use larger air compressor. p.13
System runs erratically.Air supply pressure tank undersized.Use larger pressure tank. p.13
Air supply relief valve opens.Turbine air regulator set too high.Lower setting to 23-25 psi (172-241 kPa, 1.7-2.4 bar). p.13
Turbine alternator makes high-pitched whining noise.Turbine bearings worn. (Setting turbine air regulator too high, wears bearings.)Replace bearings. Page 20. p.13
Display shows 88888 or unit reboots unexpectedly.Turbine is not supplying enough power to board.Increase turbine regulator setting to 23-25 psi (172-241 kPa, 1.7-2.4 bar). p.13
Display shows 88888 or unit reboots unexpectedly.Check turbine and electrical control exhaust air for restrictions. p.13
Display shows 88888 or unit reboots unexpectedly.Replace turbine bearings. Page 20. p.13
Xtreme Mix does not start when start but- ton is pressed.Faulty start switch or wire harness.Check start switch and wiring harness continuity; switch is normally open circuit. See Electrical Schematic, page 28. p.13
Xtreme Mix does not start when start but- ton is pressed.Faulty stop switch or wiring harness.Check stop switch and wiring harness continuity; stop switch is normally closed circuit. See Electrical Schematic, page 28. p.13
Xtreme Mix does not start when start but- ton is pressed.Bad I/O port on main board.Replace board. Page 17. p.13
Fluid valves leaking.Loose or worn packings.Tighten packing nut. If leak continues, replace packings. Page 24. p.13
Flow rate too low. In Ai Fl S M readequate air supply.Use larger CFM compressor. p.14
Flow rate too low. In Ai Fl S M rer pressure to pumps too low.Increase pressure. p.14
Flow rate too low. In Ai Fl S M reuid A or B filters plugged.Clean filters. See pump manual. p.14
Flow rate too low. In Ai Fl S M repray tip too small.Relieve pressure. Install larger tip. Follow gun manual instructions. p.14
Flow rate too low. In Ai Fl S M reixer or hoses partially plugged or too strictive.Inspect parts for cured material. Clean or replace, or use larger hoses and mixer. p.14
Pump stops after 12 cycles. Knob is set to Run pump A A or B B independently.Turn knob to spray if spraying mate- rial. p.14
Pump stops after 12 cycles. KB p.14
Xtreme Mix makes chirping noise every K 60 seconds. M fenob is set to Run pump A A or B B independently.Turn knob to spray if spraying mate- rial. p.14
Xtreme Mix makes chirping noise every K 60 seconds. M feB p.14
Xtreme Mix makes chirping noise every K 60 seconds. M featerial too heavy to siphon or gravity ed.Change material feed/supply method. p.14

Vraag stellen over de Graco 309518P

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Graco 309518P

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Graco 309518P handleiding-pdf

48 pagina's·3.3 MB·Wasmachine·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…