309524N Instr uctions High Pressure Fluid Heater VISCON HP Used f or v ariable heating of fluids. 7250 psi (50 MP a , 500 bar) Maximum W orking Pressure Important Safety Instructions Read all warnings and instr uctions in this manual. Sav e these instr uctions.
Models 2 309524N Models Hazar dous Location Heaters See Special Conditions fo r Saf e Use on page in W ar nings Section. Non-hazar dous Location Heaters Pa r t No. Series V A C (50/60 Hz single phase) / W atts / Amps Appro vals 245848 A 120 / 2300 / 19.
Contents 309524N 3 Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 T ranslatio ns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Manual Con ventions . . . . . . . . . . . . . . . . . . . . . . .
Warning 4 309524N W A RNING SKIN INJ ECTION HAZAR D High-pressure fluid from gu n, hose leaks, or ruptur ed components will pierce skin. This ma y look like just a cut, b ut it is a serious injury that can result in amputa tion. Get immediate su rgical treatment.
Warning 309524N 5 EQUIPMENT MISUSE HAZARD Misuse can cause serious injury or death. • F or prof essional use only . • Use equipment only f or its intended purpose. Call y o ur Graco distributor f or inf or mation. • Read manuals , warnings, tags, and labels bef ore operating equip ment.
Installation 6 309524N Installation T ypical Installation Dra wing The typical installation drawing is only a guide. Y our Graco distr ibutor can as sist in designing your system.
Installation 309524N 7 I Selecting T ubing Fluid loses some heat th rough the tubing or hose betwee n the heater and spr ay gun. Locate heater clo se to the spra y area to minimize heat loss throu gh plumb- ing. The chart in F IG . 2 shows a he at loss cur v e for 3 com- mon types of tubing.
Installation 8 309524N Mounting Heater W all Mounting Bracket 192585 (F IG . 3) 1. Use M8 bolts of appropriate length and loc kwasher (CC), not supplied, to mo unt brac ket. 2. Install two scre ws (6) and washers (5) into top 2 heater mounti ng posts (BB) until the y are about 1/8 in.
Installation 309524N 9 Car t Mounting (F IG . 5) 1. Place clamps (AA) around the car t vertical post (DD) and secure to the heat er mounting bars (ZZ) with M8 x 1.25 x 30 mm bolts (6) and loc kwasher (5). 2. Obser ve temperat ure ratin gs f o r the po wer cable to the terminal junction.
Installation 10 309524N Electrical Connections Requirements For All Installations 1. The volt age supply m ust agree with the maximum heater voltage and amperage. See Models , page 2. 2. Conductors used f or supply connection must be suitab le f or at least 221°F (10 5°C).
Installation 309524N 11 W all Mounted Wiring Mount a 2-pole , explos ion-proof electric s witch (H) near the heater . See F IG . 7. The s witch must meet the electri- cal codes f or your location. Also use the cor r ect cab le and plug. Car t Mounted Wiring Connect a plug that meets the electr ical codes for y o ur location.
Installation 12 309524N Determining Pr oper Fluid T emperature Use the low est temperature setting po ssible f or maxi- mum heater lif e. Use the char t in F IG . 9 to de termine the Under-Boil ® temperature. F IG . 9 also shows the eff ect of temperat ure on reducing viscosit y .
Installation 309524N 13 The char t in F IG . 10 shows the ef f e ct of tempe rature in reducing two fluids to a spra yab le viscosity , between 20 and 34 seconds using a No . 2 Zahn cup . Note that te mperature has more of an eff ect on hig h solid fluids th an on thin en amels.
Operation 14 309524N Operation Pressure Relief Pr ocedure F ollow Pressure Rel ief Pro cedure when y ou stop spra ying, and bef ore cleaning, checkin g, or ser vicing equipment. 1. Enga ge the gun s afe ty lock. 2. Sh ut off main power to the heater .
Operation 309524N 15 Setting Heater Contr ol (Refer to F IG . 11) 1. Set the heater control knob (33) to a trial setpoint of 4 or 5. 2. Star t the pump and circulate fluid thr ough the sys- tem at very low pressure, about 10-1 2 oz/min (0.30-0.35 liter/min).
Maintenance 16 309524N Maintenance Flushing Clogged fluid pa ssages are dif f icult to clean and reduce heating efficiency , flow rate , and pressure. Fl ush fre- quently , including whene ver system is not in use . 1. Follow Pressu re Relief Pro cedure , page 14.
Troubleshooting 309524N 17 T r oubleshooting Prob lem Cause Solution Heater will not heat. No current . Check circuit and fuses . Check continuity of pr imar y ther mo- stat (24), bac kup ther mostat (10), and thermal limit sensor (15). Check continuity of ther mosta t (10) and heater b lock (3) terminals - Page 18.
Repair 18 309524N Repair Hazardous Location Heaters: See F IG . 15 & 17 Non-hazar dous Location Heater s: See F IG . 16 & 18 Primary Thermostat & Probe 1. Follow Pressu re Relief Pro cedure , page 14. 2. Re mov e housing cover (18). 3. Hazardous Location Heater only: Loosen nut (27).
Repair 309524N 19 F IG . 15: Thermostat Re pair – Hazardous Location Heaters 6 Apply thermal lubr icant T orque to 89 in-lb (10 N•m) T orque nuts (62) to 10-12 in-lb (1.1-1.3 N•m) 1 2 3 5 2 16 19 15 HH 16 10 1 EE 1 3A GG 18 24 27 35 FF 1 26 28 TI12335C 25 REF.
Repair 20 309524N Thermal Limit Sensor 1. Follow Pressu re Relief Pro cedure , page 14. 2. Re mov e housing cover (18). 3. Remove nut (FF) and nut (3B) holding the le ads of the thermal limit sensor (15) an d remove the sensor . See F IG . 15 or 16, page 19.
Repair 309524N 21 F IG . 17: Contr ol Repair – Hazardous Location Heaters T orque to 89 in-lb (10 N •m) Electrical Housing Junction Bo x Apply sealant T orque nuts (62) to 10-12 in-lb (1.1-1.3 N•m) 1 2 3 4 5 1 TI2334E 6 5 18 24 29 6 5 9A 1 2 3 4 10 15 REF.
Parts 22 309524N Pa r t s Hazar dous Location Heaters ti2334E 6 5 18 24 27 25 35 26 28 29 30 33 12 16 19 15 16 10 6 5 REF. 1 1 9 2 3 7 8 5 6 32 14, 43 14, 36 4 3 T orque to 89 in-lb (10 N•m) Apply sealant Apply thermal lubr icant T orque nuts (62) to 10-12 in-lb (1.
Parts 309524N 23 Hazar dous Location Heaters ▲ Replacement Danger and W ar ning labels, tags and cards are av ailable at no cost. Pa r t N o . S e r i e s Ref. No. 3 Heater Bloc k P ar t No. V olts / W atts 245848 A 246616 120 / 2300 245862 A 246617 200 / 4000 245863 A 246618 240 / 4000 245864 A 246619 480 / 4000 246254 A 246620 380 / 4000 Ref.
Parts 24 309524N Non-Hazar dous Location Heaters 12 24 52 15 10 9 5 18 47 26 28 27 35 25 29 30 33 32 2 3 31 5 6 8 16 19 16 14, 36 14, 43 T orque to 89 in-lb (10 N•m) Apply sealant Apply thermal lubr icant T orque nuts (62) to 10-12 in-lb (1.
Parts 309524N 25 Non-Hazar dous Location Heaters ▲ Replacement Danger and W ar ning labels, tags and cards are av ailable at no cost. Pa r t N o . S e r i e s Ref.
Accessories 26 309524N Accessories Heater Con version Kit 246302: Includes two fit tings to make VISCON HP por ts match VISCON 2 Mounting Bracket 192585: Eur opean v ersion (see below) Measurements .
Accessories 309524N 27 Cable Clamp Ki t 246303 Installation 1. Slide cable clamp (3) ont o cable (2). 2. Place washer (F) on fitt ing (E). 3. Push conical-shap ed packing (D) into fitt ing (E). 4. Place washer (C) on retaining nut ( B). 5. Screw retaining n ut (B) into fitting (E).
Technica l Data 28 309524N T ec hnical Data The heater can be used in the f ollowing en vironmental conditions: indoor use , 99% maximum rela tiv e humidity , pollu- tion degr ee 2, installation cate gor y II, maximum ambient temp erature 135° F (57° C).
Dimensions 309524N 29 Dimensions Measurements – inch es (mm) L K G H J 1/2 npt(m) Fluid Inlet 1/2 npt(f) Fluid Outlet 3/4 npt(f) Electrical Conduit P or t GH J K L 9.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 309524 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC.
Een belangrijk punt na aankoop van elk apparaat Graco 309524N (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graco 309524N heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graco 309524N vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graco 309524N leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graco 309524N krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graco 309524N bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graco 309524N kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graco 309524N . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.