Gebruiksaanwijzing /service van het product 309572ZAF van de fabrikant Graco
Ga naar pagina of 36
Instructions - P arts P ower -Lock ™ Heated Hose F or use with plural component proportioners. F or professional use only . Not approved for use in European explosive atmospheres .
2 309572ZAF Contents Power -Lock Hose Bundle Part Numbers . . . . . . . . 3 Whip Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Adapter Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Standard 2 Component Hose . . . .
Power-Lock Hose Bundle Part Numbers 309572ZAF 3 P ower-Lock Hose Bundle P art Numbers Y ou need at least one 50 ft (15.2 m) main hose, one fluid temperature sensor (FTS), and one whip hose or one wire harness jumper (part no. 261821) to make a complete heated hose assembly .
Power-Lock Hose Bundle Part Numbers 4 309572ZAF Standard 2 Component Hose RTD 2-Component Hose (for use with GCA Controlled Reactors) Hose Assembly Length ft (m) ID in.
Power-Lock Hose Bundle Part Numbers 309572ZAF 5 Airless 2 Component Hose Custom Application 2 Component Hose ✖ Stranded wire (no connectors). ‡ T wo F TS cables and two sets of standard wires. 24N001 50 (15.2) 1/2 (13) ✔✔ ✔ -8 JIC -10 JIC 246063 246064 3500 psi (24.
Power-Lock Hose Bundle Part Numbers 6 309572ZAF Fluid T emperature Sensor (F TS) Kits Fluid T emperature Sensor Kits (F TS, RTD; for use with GCA Controlled Systems) FTS kits contain: • F TS Sensor • F TS coupler fitting (5b) for equal length on other line.
Warnings 309572ZAF 7 W arnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk.
Warnings 8 309572ZAF TOXIC FL UID OR FUMES HAZARD T oxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDSs to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
Important Two-Component Material Information 309572ZAF 9 Important T wo-Component Material Information Isocyanate Conditions Material Self -ignition K eep Components A and B Separate PERSONAL PROTECTI.
Important Two-Component Material Information 10 309572ZAF Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid.
Installation 309572ZAF 11 Installation Description The heated hose maintains proper fluid tem- perature while spraying. Fluid hoses are marked with red tape for ISO/hardener/minor volume side, blue tape for RES/resin/major volume side.
Installation 12 309572ZAF Connect Whip Hose to Gun or Gun Manifold 1. Overlap A and B component hoses and assemble to gun or gun manifold fittings as shown in F IG . 1. 2. Tighten fittings to A and B component hoses. Ensure hose remains flat after fit- tings are tightened.
Installation 309572ZAF 13 Connect Heated Hoses 1. Lay heated hoses end to end, matching the color coding. Red for component A (ISO), blue for component B (RES). 2. Connect fluid hoses (1, 2) and tighten. See maximum torque specifications below and F IG .
Installation 14 309572ZAF 4. Connect electrical wires. a. Ensure electrical wires ends are 5/8 in. (15.9 mm) long. If they are not, use a sharp scissors to strip all four wire ends to the correct length. See Strip Length Gauge for correct length. a. Ensure strip length is correct by fitting ferrule over exposed wire.
Installation 309572ZAF 15 5. P air electrical wires as follows: A-Hose to A-Hose; B-Hose to B -Hose. a. Insert one wire from heated hose into connector . Ensure that ferrule is mating with connector insert. See F IG . 8. b. Thread in setscrew and use hex wrench to torque setscrew to 60 in-lbs (6.
Installation 16 309572ZAF 6. F or non-RTD hoses only , connect cables (4). Slide insulator sleeves (S) over con- nection. Leave slack in cables as stress relief to prevent cable failure. 7. F or RTD 2-component hoses only , connect RTD cables (4) and CAN cables (5) if pres- ent.
Installation 309572ZAF 17.
Installation 18 309572ZAF Connect F TS and Heated Dual Whip Hose 1. Assemble JIC swivel fitting (5e) in female end of temp sensor (5a). Do not bend or kink probe. T orque connection to 14 ft-lbs (19 N•m). Do not over -torque. Assemble JIC swivel fitting (5d) into female end of B hose coupler (5b).
Installation 309572ZAF 19 F IG . 13 2 1 6a 6b K 5c 12 5b 8 TI17091b 4 9 S S T o Gun T o Proportioner 3 5a TI18392b Non-RTD Hoses RTD 2-Component Hoses 5a 1 2 5b 6a 6b K 12 3 8 4 5c 14 5d 5e 5d 5e.
Installation 20 309572ZAF Connect F TS with a Non-Heated Whip Hose or Remote Mix Manifold 1. Carefully extend FTS probe (H) into the hose section from the proportioner . Do not bend or kink probe. Insert probe in major volume (resin) side on systems which are not 1:1 mix ratio.
Installation 309572ZAF 21 Check Hoses for Leaks 1. Grease with F usion ® grease and connect fluid hoses to proportioner fluid manifold (M). Red for hardener (ISO), blue for resin (RES). 2. F or spray guns, close fluid valves on gun fluid manifold. Remove manifold from gun, see gun manual.
Installation 22 309572ZAF Protective Covering 1. Wrap all fluid hose connections with electri- cal tape. 2. F old wire back on hose to ensure adequate strain relief. Wrap all electrical connections and cable connections with electrical tape to protect them from pulling apart and abra- sion.
Operation 309572ZAF 23 Operation 1. Connect air hose to main air supply , if equipped. 2. Connect electrical connectors (12) to con- nector from fluid manifold (M) or accessory control box. See Connect Heated Hoses , page 13. Connect hose cable (4) to cable from proportioner fluid manifold or acces- sory control box.
Maintenance 24 309572ZAF Maintenance 1. Before disconnecting or repairing hoses, relieve all fluid pressure and shut off electri- cal power to proportioner .
Parts 309572ZAF 25 P arts Using 261669 Fluid T emperature Sensor (JIC to JIC fittings) ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. WLE 2 5b 4 Heated Fluid Hose Fluid T emperature Sensor Whip Hose 1 12 3 5a 5c 8 6 9 5d 5e Ref.
Parts 26 309572ZAF Using 24M943 Fluid T emperature Sensor (NPT to NPT fittings) ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. ★ Not included. Order connector fittings that connect to the A and B component hoses.
Parts 309572ZAF 27 Using 24K207 RTD 2-Component Hose Fluid T emperature Sensor (JIC to JIC fittings) ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. * Included only in hoses with CAN cable. See RTD 2-Component Hose (for use with GCA Controlled Reactors) , page 4.
Parts 28 309572ZAF Using 24M944 RTD 2-Component Hose Fluid T emperature Sensor (NPT to NPT fittings) ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. * Included only in hoses with CAN cable. See RTD 2-Component Hose (for use with GCA Controlled Reactors) , page 4.
Parts 309572ZAF 29 Using 261670 Fluid T emperature Sensor (JIC to NPT fittings) ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost.
Parts 30 309572ZAF 15F144 Hose Wire Jumper Use the 15F144 Hose Wire Jumper to heat only the major volume hose, in a wide ratio system. T o build one complete 50 ft single side heated hose bundle, order the following parts: Install as follows: 1. Wrap hose wire jumper (100) around resin hose (101) in a spiral fashion.
Parts 309572ZAF 31 8. Install whip hose and gun. Ensure that gun is grounded. 9. Connect hoses to proportioner . 10. Insulate and protect hoses. See Protective Covering , page 22. Set transformer wire taps, using the following table. T ransformer tap wire connections vary depending on length of heated hose.
Accessories 32 309572ZAF Accessories Scuff Guard Use to keep hose clean and protect it from damage. P art Description 246077 7 ft (2.1 m) braided polyester mesh. For whip hose. F old back over itself for easy installation. 246078 50 ft (15.2 m) braided polyester mesh.
Technical Data 309572ZAF 33 T echnical Data Power -Lock Heated Hose US Metric Maximum Air Working Pressure 130 psi 0.9 MPa, 9 bar Maximum Fluid Operating T emperature 180°F 82°C Wetted P arts Nylon, Zinc-Plated Carbon Steel, 303 Stainless Steel T otal Heating Load (2 Hoses) 1/4 in.
Technical Data 34 309572ZAF * These models include the Xtreme- Wrap Scuff Guard. RTD 2 Component Hose (For GCA Reactors) Maximum Fluid W orking Pressure 24K240 2000 psi 14 MP a, 138 bar 24K241 3500 ps.
Technical Data 309572ZAF 35.
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. )RUSDWHQWLQIRUPDWLRQVHHZZZJUDFRFRPSDWHQWV Original instructions.
Een belangrijk punt na aankoop van elk apparaat Graco 309572ZAF (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graco 309572ZAF heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graco 309572ZAF vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graco 309572ZAF leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graco 309572ZAF krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graco 309572ZAF bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graco 309572ZAF kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graco 309572ZAF . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.