Gebruiksaanwijzing /service van het product 312877C van de fabrikant Graco
Ga naar pagina of 24
Operation Husky ® 1050 Air -Operated Diaphra gm Pump 312877C ENG 1-inch pump with modular air v al ve for fluid transf er applications See page 3 f or model inf ormation, including appr o v als. 125 psi (0.86 MP a, 8.6 bar) Ma ximum Fluid W or king Pressure 125 psi (0.
Related Manua ls 2 312877C Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Pump Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A TEX Cer t ifications . . . . . . . . . . . . . . . . . . . . . .
Pump Matrix 312877C 3 Pump Matrix Check the identification plate (ID) f or the 20-digit par t number of you r pump . Use the follo wing matrix to define the components of y our pump .
Warnings 4 312877C Wa r n i n g s The f ollo wing warnings are for the setup , use, grounding, maintenance , and repair of this equip- ment. The e xclamation point symbo l aler ts you to a gener al warni ng and the hazard symbol refe rs to procedure-specific risk.
Warnings 312877C 5 EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injur y . • Do not operate the unit when f atigued or under th e influence of drugs or alcohol. • Do not e xceed the maximum w orking pressure or temperature ra ting of the lo west rated system component.
Installation 6 312877C Installation The T ypical Installations shown in F IG . 3 and F IG . 4 are only guides f o r selecting and install- ing system components. Contact y our Graco distributor f o r assistance in planning a system to suit your needs .
Installation 312877C 7 Mounting 1. Be sure the mounti ng surf ace can suppor t the weight of the pu mp , hoses, and acces- sories, as well as the stress caused during operation. 2. F or all mountings, be sure the pump is bolted directly to the mounting surf ace .
Installation 8 312877C Check y our system electr ical continuity after the initial installation, and then set up a regular schedule f or chec king continuity to be sure proper grounding is maintained. Air Line See F IG . 3 and F IG . 4, pages 10 and 11.
Installation 312877C 9 Fluid Suppl y Line See F IG . 3 and F IG . 4, pages 10 and 11. 1. Use grounded fluid supply lines (G). See Grounding , page 7. 2. If the inlet fluid pre ssure to the pump is more than 25% of t he outlet working pres- sure, the ball chec k v alv es will not close f ast enough, resulting in inefficient pump operation.
Installation 10 312877C F IG . 3. T ypical bung-mount installation (alumin um, 1050A, pump show n) E F CB A KL J R H G D M N M ti14163a.
Installation 312877C 11 Key fo r F IG . 3 and F IG . 4: A Air supply line B Bleed-type ma ster air v alv e (required f or pump) C Air regulator D Air inlet E Master air v alve (f or accessor ies) F Air line filter G Fluid suction line H Bung adapter J Fluid drain v alve (required) K Fluid shutoff v alv e L Fluid line M Fluid inlet (Aluminum, F IG .
Installation 12 312877C Fluid Inlet and Outlet P or ts NO TE: Remov e and rev erse the manifold(s) to change the orientation of in let or outl et por t(s). Fo l l o w T orque Instructions on page 16. Aluminum ( 1050A ) The fluid inlet and outle t manif olds each hav e f our 1 in.
Installation 312877C 13 Fluid Pressure Relief V alve F IG . 6. Fluid pressure relief kit (Aluminum pumps only , 1050A models) Some systems ma y requi re installation of a pressure relief v alv e at the pump outlet to pre- v ent ov er pressurization and rupture of the pump or hose.
Operation 14 312877C Operation Pressure Relief Pr ocedure 1. Shut off the air supply to the pump . 2. Open the dispensing v alv e, if used. 3. Open the fluid drain v alv e to relie v e fluid pressure. Ha v e a container ready to catch the drainage . Flush the Pump Bef ore Fir st Use The pump was tested in w ater .
Maintenance 312877C 15 10. If you are flushi ng, run the pump long enough to thoroughly clean the pump and hoses. 11. Close the dispensing valv e, if used. 12. Close the bleed-ty pe master air v alve . 13. Pumps with r una wa y protection: Disab le the prime/flush func tion by pushing the prime/flush button on the DataT rak.
Maintenance 16 312877C T orque Instructions NO TE: Fluid cov er and manif old f asteners hav e a thread-locking adhesiv e patch applied to the threads. If this patch is e xcessively w or n, the f asteners ma y l oosen during operation. Replace screws with new ones or apply medium-strength (blue) Lo ctite or equiv alent to the threads.
Maintenance 312877C 17.
Dimensions and Mounting 18 312877C Dimensions and Mounting Aluminum ( 1050A ) A B C D E F G ti12212a ti12211a ti12213a J K L N P M H 5.5 in. (140 mm) 5.0 in. (127 mm) ti14540a A ..... 12.7 in. (323 mm) B ..... 14.4 in. (366 mm) C ..... 15.9 in. (404 mm) D .
Dimensions and Mounting 312877C 19 P olypr opylene ( 1050P ) and Conductive P ol ypr opylene ( 1050C ) A B C D E F G H ti13845a ti13847a ti13846a J K N P M L 10.3 in. (262 mm) 5.0 in. (127 mm) ti14541a A ..... 13.2 in. (335 mm) B ..... 15.7 in. (399 mm) C .
Dimensions and Mounting 20 312877C Stainless Steel ( 1050S ) A B C D E G ti14343a ti14344a ti14345a K N P M L H J 5.5 in. (140 mm) 5.0 in. (127 mm) ti14542a A ..... 11.8 in. (300 mm) B ..... 12.9 in. (328 mm) C ..... 13.7 in. (348 mm) D ..... 9.5 in. (24 1 mm) E.
Performance Charts 312877C 21 Pe r f o r m a n c e C h a r t s T est Conditions: Pump tested i n wate r with inlet submerged. 0 51 0 15 20 25 30 35 40 45 50 (19) (38) (57) ( 76) (95) (114) (133) (152) (170) (189) A B C D How to Read the Charts 1. Locate fluid flo w rate along bottom of chart.
Technica l Data 22 312877C T e c hnical Data * Sound pow er measured per ISO-9614-2. ** Sound pressure w as tested 3.28 ft (1 m) from equipment. All trademarks mentioned in this manual are the proper ty of their respectiv e owners . Maximum fluid working pressure .
Technical Data 312877C 23 Fluid T emperature Range * The maximum te mperature listed is based on th e A TEX stan dard for T4 temperature clas sification. If you are operat ing in a non-e xplosiv e en vironment, FKM fluor oelasto mer’ s maximum fluid temperature in aluminum or stainless steel pumps is 320°F (160°C).
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 312877 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC.
Een belangrijk punt na aankoop van elk apparaat Graco 312877C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graco 312877C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graco 312877C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graco 312877C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graco 312877C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graco 312877C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graco 312877C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graco 312877C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.