Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001 10:1 Fire–Ball r 425 Pump Low–pressure, medium volume pump used to transfer grease. 1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure 180 psi (1.
2 309407 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 7 . . . . . . . . . . . . . . . . . .
3 309407 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being dispensed to. Refer to Grounding on page 5.
4 309407 W ARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before operating the equipment.
5 309407 Installation NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Accessories, available from your Graco distributor . Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below .
6 309407 Installation Mount the pump to suit the type of installation planned. V ery heavy lubricants may require an inductor plate. See page 16 for the mounting hole layout and dimensions Install the air line accessories in the approximate order shown in the T ypical Installation.
7 309407 Operation W ARNING D This pump is designed to be used ONL Y in pumping non-corrosive and non-abrasive lubri- cants and greases. Any other use of this pump can cause unsafe operating conditions and result in component rupture, fire, or explosion, which can can cause serious bodily injury , including injection.
8 309407 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Before servicing this equipment always make sure to Relieve the Pressure .
9 309407 Notes.
10 309407 Service TI2148A Fig. 3 12 11 6 25 15 2 31 3 14 4 30 16 5 7 8 9 10.
11 309407 Service Displacement Pump Repair W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Before you start: D T o reduce down time, be sure you have all necessary repair parts available.
12 309407 Service 12. Slide priming plate (9) (beveled edge up) onto priming rod (8). Screw nut (10) onto priming rod and tighten. 13. Reconnect the pump’s ground wire to a true earth ground. Check V alve Adjustment This pump has an adjustable piston ball check.
13 309407 Notes.
14 309407 Parts TI2147A 1 13 12 3 4 14 15 35* 34* 36* 33* 20 36* 34* 35* 16 8 2 31 5 30 6 11 7 9 10 Packing, vee* Spacer*.
15 309407 Parts Model 965124, Series B stubby length Model 965129, Series B 400 lb. (180 Kg) drum length Ref No. Part N o. Description Qty . 1 { AIR MOT OR 1 2 183010 CYLINDER, pump, displacement (mod.
16 309407 Dimensions Priming Piston 6.5 in. (165 mm) Diameter 1” npt(f) Fluid Outlet 28.5 in. 13.9 in. (724 mm) (353 mm) 14 .6 in. (371 mm) 1/2 npt(f) Air Inlet TI2146A Model 965124 Model 965129 37.3 in. (947.4 mm) Model 965124 Model 965129 50.8 in.
17 309407 T echnical Data Fluid pressure ratio 10:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air pressure operating range 40–180 psi (0.
18 309407 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Een belangrijk punt na aankoop van elk apparaat Graco 965124 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graco 965124 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graco 965124 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graco 965124 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graco 965124 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graco 965124 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graco 965124 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graco 965124 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.