NL
Graco logo
Officiële handleiding

Graco Inc. 253015

40 pagina's·3.3 MB·Verfspuit·PDF·ENDEFRITJA
Graco Inc. 253015
Inhoudsopgave 2 secties Models · Warnings TonenVerbergen
Page 1 of the Graco Inc. 253015 user manual — - For the application of architectural paints and coatings -
Pagina 1 · klik om te vergroten
Pagina 1

Operation / Fonctionnement / Funcionamiento Funzionamento / Funcionamento / Bediening

Electric Airless Sprayers Pulvérisateurs électriques type Airless Pulverizadores eléctricos sin aire Spruzzatori airless elettronici Equipamentos de Pintura a Alta Pressão Eléctricos Elektrische airless spuittoestellen

Graco Inc. 253015 — Operation / Fonctionnement / Funcionamiento Funzionamento / Funcionamento / Bediening diagram (page 1)
Afb. 1 · Operation / Fonctionnement / Funcionamiento Funziona…

3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure

- For the application of architectural paints and coatings -

- Pour l’application de peintures et revêtements architecturaux - - Para la aplicación de pinturas y revestimientos con fines arquitectónicos - - Per l’applicazione delle vernici e dei rivestimenti architettonici - - Para a aplicação de pinturas e demãos arquitectónicas - - Voor het spuiten en aanbrengen van muurverf en coatings -

UltraTM 395/495/595 UltraMax IITM 490/495/595 Ultimate NovaTM 395

Ultimate MX IITM 490/495/595 ST Max IITM 490/495/595 Super NovaTM 495/595

ST MaxTM 395/495/595

Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001

ti7374a · ti2399a

Page 2 of the Graco Inc. 253015 user manual — Models
Pagina 2 · klik om te vergroten
Pagina 2

Models

VACModel 120Ultra 395 Ultimate Nova 395233960 826014233961233962 Ultra 495 Super Nova 495233966 826017233967 826018233968 826019 Ultra 595 Super Nova 595234490 826052234435 826046 Ultra Max II 490 Ultimate MX II 490249911 825028249913 825029249914 825036 Ultra Max II 495 Ultimate MX II 495249915 825037249916 825038249917 825039 Ultra Max II 595 Ultimate MX II 595249918 825046249919 825045 230 CEEST Max 395 Hopper233955 ST Max 395234176258662 ST Max 495233956233970233971 ST Max 595248661244437 ST Max II 490 Hopper253011 ST Max II 490249926253012253013 ST Max II 495249928253014249978 ST Max II 595253015249930 230 EuropeST Max 395223963 ST Max 495233957233975 ST Max 595244436 ST Max II 490249927 ST Max II 495249929249979 ST Max II 595249931 110 UKST Max 395223972 ST Max 495233973233975 ST Max 595244436 ST Max II 490249935 ST Max II 495249936249980 ST Max II 595249937 230 AsiaUltra 395234180 Ultra 495234183234181234182 Ultra 595248660244439 Ultra Max II 490249932 Ultra Max II 495249933253104253105 Ultra Max II 595253107249934 100 JapanUltra Max 495234186233974 Ultra Max II 495249938253106

Models

Page 3 of the Graco Inc. 253015 user manual — WARNING
Pagina 3 · klik om te vergroten
Pagina 3

Warnings

The following are general warnings related to the setup, use, grounding, maintenance and repair of this equipment. Additional, more sepcific warnings may be found throughout the body of this manual where applicable. Symbols appearing in the body of the manual refer to these general warnings. When these symbols appear throughout the manual, refer back to these pages for a description of the specific hazard.

WARNING

  • FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
  • Use equipment only in well ventilated area.
  • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).
  • Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.
  • Keep work area free of debris, including solvent, rags and gasoline.
  • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
  • Ground equipment and conductive objects in work area. Read Grounding instructions.
  • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
  • Keep a fire extinguisher in the work area.
  • ELECTRIC SHOCK HAZARD Improper grounding, setup, or usage of the system can cause electric shock.
  • Turn off and disconnect power cord before servicing equipment.
  • Use only grounded electrical outlets.
  • Use only 3-wire extension cords.
  • Ensure ground prongs are intact on sprayer and extension cords.
  • Do not expose to rain. Store indoors.
  • SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
  • Do not point gun at anyone or at any part of the body.
  • Do not put your hand over the spray tip.
  • Do not stop or deflect leaks with your hand, body, glove, or rag.
  • Engage trigger lock when not spraying.
  • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
Page 4 of the Graco Inc. 253015 user manual — Warnings
Pagina 4 · klik om te vergroten
Pagina 4
WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. Read Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. Read Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your Graco distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or overbend hoses or use hoses to pull equipment. • Comply with all applicable safety regulations. • Keep children and animals away from work area. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. PRESSURIZED ALUMINUM PARTS HAZARD Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, serious injury, and property damage. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eye wear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection

Vraag stellen over de Graco Inc. 253015

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Graco Inc. 253015

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Graco Inc. 253015 handleiding-pdf

40 pagina's·3.3 MB·Verfspuit·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…