F: W06 AldesW06 DOCFILES 782DHV - 150HInst.doc 782DHV150H - 10 - 00 Rev: 10 / 30 / 2002 DHV - 150H DEHUMIDIFYING VENTILATOR INSTALLATION OPERATION MAINTENANCE 782DHV12 - 00 DHV - 150H Indoor Air Quality System Installation, Operation & Service Instructions Table of Contents 1.
2 • Avoid dischargi ng the air directly at people, or over the water in pool areas. • If used near a pool or spa, be certain there is NO chance the unit could fall into the water or be splashed and that it is plugged into a GROUND FAULT INTERRUPTER.
3 An optional condensate pump kit may be installed if a lift is required to dispose of the condensate. The cond - ensate pump kit can be ordered direct from the factory.
4 posit ively or negatively, depending upon the inside and outside air conditions. Consult the factory by calling 1 - 800 - 255 - 7749 for recommendations regarding the use of higher flows with your specific application. The outside air duct should be connected to the 6” round collar on the filter enclosure of the unit.
5 2.5 Quiet Ins tallation Remove Shipping Restraints The compressor is attached to the cabinet with two cable ties to secure it during shipment. This rigid attachment is not necessary once the unit is installed and may cause noise from compressor vibration .
6 Figure 1: DHV - 150H in a Basement With a Forced Air System Incorporating a Central Return Figure 2: DHV - 150H in an Attic with a Forced Air System Incorporating a Cent ral Return.
7 3 Operation The DHV - 150H can be equipped with various accessories to enhance its operation. A remote control panel must be used with the DHV - 150H. There are two remote control panels from which to choose. The humidity/fan control panel is use d to control humidity and the fan.
8 The ventilation timer is an electronic timer that displays the current time. This timer has a battery backup, so it will not req uire resetting after a power outage. Following a prolonged power outage the display of the timer will flash on and off indicating a power outage has occurred.
9 4 Maintenance 4.1 Standard Air Filter The DHV - 150H is equipped with a pleated cloth air filter. This filter should be checked semi - annually. Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency and may cause the co mpressor to cycle off and on unnecessarily on the defrost control.
10 maintain nearly constant pressure and temperature across the entire coil, from inlet to outlet. The mixture of gas and liquid refr igerant enter the accumulator after leaving the evaporator coil. The accumulator prevents any liquid refrigerant from reaching the compressor.
11 6. Turn on the fa n switch; the fan should run. Turn off the fan switch. 7. Turn on the humidity control; the compressor and fan should run. 8. If these tests work, the problem is most likely in the field control wiring.
12 in the compressor mot or, the resulting high temperature arc causes a portion of the refrigerant oil mixture to break down into carbonaceous sludge, a very corrosive acid, and water. These contaminants must be carefully removed otherwise even small residues will attack replacem ent compressor motors and cause failures.
13 5.7B Programmable Ventilation Timer The ventilation timer controls the fan and the motorized fresh air damper. When the ventilation timer is activate d, the central conditioning unit will circulate the indoor air, and bring in fresh air from outside.
14 Figure 4. Electric Schematics of the DHV - 150H.
15 Figure 5: Pictorial Electrical Diagrams of DHV - 150H.
16 SERVICE PARTS LI ST: DHV - 150H Indoor Air Quality System ITEM PART NO. QTY. DESCRIPTION 1 AL98996 1 Air Filter, Pleated Cloth 2 4017777 2 Capillary Tube, .
17 OPTIONAL PARTS LIST: DHV - 150H Indoor Air Quality System ITEM PART NO. QTY. DESCRIPTION 25 AL9899 5 1 Air Filter, High Efficiency, Pleated Microglass Paper, 90 % - 95 % 26 AL99027 1 Check Damper, .
18 Limited Warranty American ALDES Ventilation Corporation warran ts to the original end user of the Dehumidifier or Dehumidifying Ventilator model referred to below, to be free from manufacturing defects. It is limited to the original end - user and may not be assigned or transferred.
19 Date Service Notes.
Een belangrijk punt na aankoop van elk apparaat American Aldes DHV-150H (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen American Aldes DHV-150H heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens American Aldes DHV-150H vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding American Aldes DHV-150H leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over American Aldes DHV-150H krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van American Aldes DHV-150H bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de American Aldes DHV-150H kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met American Aldes DHV-150H . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.