Gebruiksaanwijzing /service van het product 765000 van de fabrikant Graham Field
Ga naar pagina of 24
765000 AL TERNA TING PRESSURE MA TTRESS SYSTEM WITH ACTIVE SENSOR TECHNOL OGY USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. Info: The most current version of this manual can be found online at www.
2 765000-INS-LAB-RevC11 CONTENTS INTRODUCTION..................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION .
765000-INS-LAB-RevC11 3 INTRODUCTION Use this manual for set-up and operation of the Lumex ® AltaDyne ® Sensor Plus 765000 Alternating Pr essur e Mattr ess System with Active Sensor T echnology . Read all instructions befor e using the mattr ess system.
4 765000-INS-LAB-RevC11 IMPORT ANT SAFETY PRECA UTIONS The safety statements pr esented in this chapter r efer to the basic safety information that should be obser ved by those using this Mattr ess System.
765000-INS-LAB-RevC11 5 WARNING T o reduce the risk of bur ns, electrocution, r e, or per sonal injur y: W ARNING:Donotleavethisproductunattendedwhen pluggedin.
6 765000-INS-LAB-RevC11 W ARNING:Patiententrapmentwithbedsiderails maycauseinjuryordeath.Thebedframeandits components,includingthemat.
765000-INS-LAB-RevC11 7 EQUIPMENT SYMBOLS Manufacturer “BF”symbol: Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Functi.
8 765000-INS-LAB-RevC11 PRODUCT DESCRIPTION PUMP AND MA TTRESS SY STEM pumpandmattresssystem CPRvalves quickconnectors (mattress-pump connectors) mattress footend symbol pump PUMP.
765000-INS-LAB-RevC11 9 PUMP: FRONT P ANEL Fr ont panel of pump is shown below . Descriptions of buttons and indicators follow . T uningbutton; indicatorsatleftofbutton Powerfailu.
10 765000-INS-LAB-RevC11 Tuning button: The tuning button ne-tunes the mattr ess system's auto-adjusted pr essur e. Thr ee tuning settings ar e available: 0 System auto-adjusted pr essur e .
765000-INS-LAB-RevC11 11 Maxfir m button: The pump will automatically enter maxrm mode ever y time the power is turned on. Maxrm mode ensur es the pump is able to r each its maximum operating pr essur e. Maxrm mode will last for 20 minutes, and then the system will automatically enter auto-adjust mode.
12 765000-INS-LAB-RevC11 Low pr essur e indicator: The low pressur e indicator (yellow LED) illuminates, and the alarm sounds, when an abnormally low pr essur e level occurs. If the low pr essur e indicator persistently illuminates inappr opriately: 1.
765000-INS-LAB-RevC11 13 INST ALLA TION UNP ACKING 1. Car efully r emove all components fr om the carton. 2. Inspect all components. 3. If damage is evident to the contents, please notify the carrier and your Graham-Field equipment pr ovider . PUMP AND MA TTRESS SETUP 1.
14 765000-INS-LAB-RevC11 W ARNING:Locateallcordssothattheywillnotbe steppedon,trippedover ,orotherwisesubjectedto damageorstress. W ARNING: Donotuseahouseholdextensioncordifthe electricalcorddoesnotreachthepoweroutlet.
765000-INS-LAB-RevC11 15 OPERA TION GETTING ST AR TED 1. T urn the main power switch to the ON position. 2. Pr ess the fr ont panel power button. The power indicator will illuminate.
16 765000-INS-LAB-RevC11 TRANSPORT CAP In case of power failur e or transport: Disconnect the quick connector and cap the mattr ess with the transport cap to slow deation. Info: This system is equipped with cell-on-cell technology to provide added support and prevent bottoming out in the event of a power failure.
765000-INS-LAB-RevC11 17 MAINTENANCE CLEANING W ARNING: To reducetheriskofincreasedbacterial growth,infection,illness,orinjuryfromcontamination, tho.
18 765000-INS-LAB-RevC11 Fuse replacement tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e at right).
765000-INS-LAB-RevC11 19 SPECIFICA TIONS Pump Specication Power Supply (Info: see rating label on product) AC 120V 60 Hz 0.17A (for 120V system) Fuse Rating T1A, 250V Cycle time Fixed / 10 minutes Dimensions (L x W x H) 1 1.4" x 7.9" x 4.
20 765000-INS-LAB-RevC11 LIMITED WARRANTY GF Health Pr oducts, Inc. warrants the Lumex ® AltaDyne ® Sensor Plus 765000 Alternating Pr essur e Mattr ess System with Active Sensor T echnology for a period of twelve months for defects in workmanship and materials.
765000-INS-LAB-RevC11 21 APPENDIX A: EMC INFORMA TION Guidance and Manufacturer’s De claration- Electromagnetic Emissions: This device is intended for use in the electromagnetic environment specified below . The user of this device should make sure i t is used in such an environmen t.
22 765000-INS-LAB-RevC11 Guidance and Manufact urer ’ s Declaration- Electromagn etic Immunity: This device is intended for use in the electromagnetic environment spec ified bel ow . T he user of t his device should ma ke sure it is us ed in such an environment.
765000-INS-LAB-RevC11 23 a The ISM (indu str ial, sc ient ific and medical) bands between 150 kHz and 80 MHz are 6,765 MHz to 6,795 MHz;13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 M Hz to 40,70 MHz.
USA Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 fax: 770-368-2386 www .grahamfield.
Een belangrijk punt na aankoop van elk apparaat Graham Field 765000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graham Field 765000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graham Field 765000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graham Field 765000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graham Field 765000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graham Field 765000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graham Field 765000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graham Field 765000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.