US0208-INS-LAB-RevD1 1 MODEL US0208 / US0208PL SEMI-ELECTRIC BED MODEL US0458 / US0458PL FULL-ELECTRIC / LO W BED USER MANU AL READ THIS MANU AL BEFORE OPERA TING THE P A TRIO T ™ HOMECARE BED . SA VE THIS MANU AL FOR FUTURE USE. INFO: THE MOST CURRENT VERSION OF THIS MANU AL CAN BE FOUND ONLINE A T www .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 2 GF H ea lt h Pr od uct s, I nc . is n ot re sp on si bl e fo r typ og ra ph ic al e rr or s. Pa ck ag in g, w ar ran ti es , pr od uc ts an d sp ec i ca ti on s are s ub je ct t o ch ang e wi th ou t no ti ce.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 3 1 SAFETY The safety statements pr esented in this chapter refer to the basic safety information that the op- erator of the Patriot Homecar e Bed shall pay attention to and abide by .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 4 2 INTRODUCTION, P A TRIO T HOMECARE BED USER MANU AL This manual contains assembly and maintenance instructions for your Model US0208 / US0208PL Semi-Electric and US0458 / US0458PL Full-Electric / Low Patriot bed.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 5 3 ASSEMBL Y INSTRUCTIONS HEAD AND FOO T ASSEMBL Y foot section head section motor cam hook rivet hook rivet Assembly , head and foot sections Note: Grid deck not shown for clarity 1.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 6 MO T OR ASSEMBL Y W ARNING: Assemble motor on bed as follows. While it is possible to install the motor backwards, avoid it! Incorrect installation could cause the bed to move in unexpected ways. Note that the motor ends are labeled and embossed with head and foot symbols (shown at right).
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 7 Install motor slide caps 7. Position the caps as shown at right so that the gr ooves in the slide cap are aligned with the gr ooves in the motor . 8. Apply straight downwar d pressur e to each end of the cap while sliding into the closed position.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 8 FULL-ELECTRIC BED ONL Y (US0458 / US0458PL): CASTER POSITION Any full-electric Patriot bed can be used as either a standar d-height or low-height bed by moving the casters.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 9 BED END ASSEMBL Y All bed models: Assemble bed head end 1. Insert one locking and one non-locking caster into bed end. Locking casters must be installed diagonally fr om each other . See pr evious page for full-electric caster position options.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 10 All models: Install bed end locking hardwar e 1. After bed head end has been attached, install Bed End Locking Har dwar e to act as a latch for each corner .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 11 d f e 5. Fr om the inside, reattach the hairpin clip to the cor d’ s looped end as shown in d . This pr events the cor d from slipping back thr ough the frame bracket hole.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 12 Full-electric bed only (US0458 / US0458PL): Assemble hi/lo motor shaft to foot end gear bo x notches in hi/lo motor shaft coupler slide over gear box.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 13 HI/LO R OD ASSEMBL Y / BED LENGTH The hi/lo r od assembly consists of an inner and outer tube with a spring button lock to keep them together .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 14 All models: Attach hi/lo rod to gearbo x or motor shaft pins Both ends of the hi/lo r od assembly have a slot to mount on the foot end motor shaft pins and bed end gearbox shaft pins. Follow steps 2-3 to mount the hi/lo r od assembly on the gearboxes.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 15 4 BED OPERA TION W ARNING: Ensure that bed is secure and assembled as instructed on previous pages before operating. Plug the power cor d into any grounded outlet. W ARNING: Do not leave the bed unattended when plugged in.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 16 CRANK OPERA TION: SEMI-ELECTRIC BED ONL Y (US0208 / US0208PL) Use the crank at the center foot of the semi- electric bed (shown at right) to change bed height (raise or lower entir e deck). TRENDELENB URG POSITION, ALL MODELS (HEAD END A T L OWER ELEV A TION THAN FOO T END) 1.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 17 5 SPECIFICA TIONS, ALL MODELS * * Specifications are subject to change without notice. Deck height High position Deck height: High Position US0208 / US0208PL: 24.0 inches US0458 / US0458PL with cast- ers in low position: 20.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 18 6 A CCESSORIES: BED RAILS Patriot Homecar e Bed decks are equipped with patent-pending slots specically for bed rail instal- lation, pr oviding a xed place to mount GF bed rails.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 19 GF6580B-1: Quar ter Rail GF6580B-1 Quarter Rail head end slot slotted head deck angle foot end head end slots head end pivot point pivot point slot f.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 20 L UMEX UNIVERSAL BED RAILS If you install Lumex universal bed rails, follow the installation instructions that accompany them; the following instructions ar e provided to describe the differ ences between the installation of bed rail cr ossbraces on Patriot grid beds and spring beds.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 21 GF6580A-1: Low Univ ersal Half Rail GF6580A-1 Low Universal Half Rail Cable tie Spr ing Bu tt on s with cable ti e Secu re cr ossb race to head de ck angle FOOTBOAR D Spr ing Bu tt on s G3 A G2 HEADBOARD B Fo llow same procedure for mounting half rails on foot-end using G3 slots .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 22 7 SERVICE P AR TS, ALL MODELS Ser vice par ts for all bed models ar e shown below and on the following two pages. See pictures and tables for appr opriate ser vice par ts. Info: T o order ser vice par ts, contact our Customer Service depar tment at 800-365-2338 (fax 920-929-8213).
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 23 BED END COMPONENTS 3 5 6 7 4 1 2 8 HEAD FOOT Item Part number Description Semi-electric Full-electric US0208 US0208PL US0458 US0458PL 1 690-7001-901 .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 24 BED SERVICE P ARTS 1 HEAD FOOT 2 3 4 Item Part number Description Semi-electric, H7920SE Full-electric, H7920FE US0208 / US0208PL US0458 / US0458PL 1.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 25 8 MAINTENANCE AND SAFETY CHECKS Perform the following as needed or between patient placements, whichever happens sooner: Electronics and Motor s Check all controls to ensure that all functions work properly .
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 26 9 WARRANTY GF Health Pr oducts, Inc. warrants the Patriot US0208 / US0208PL Semi-Electric Homecar e Bed Patriot US0458 / US0458PL Full-Electric / Low Bed as follows: T wo-year limited warranty for defects in workmanship and materials of mechanical components, frame, and electr onics.
US0208-INS-LAB-RevD1 1 • Patriot Homecare Bed 27 10 INDEX A Assembly instructions 5 B Bed end assembly 9 Bed end locking hardwar e, install 10 Bed extension kit, 84” 17 Bed height, low , full-elec.
U .S .A. Corporate Headquarters: GF Health Pr oducts, Inc. (“Graham-Field”) 2935 Northeast Parkway Atlanta, Geor gia 30360 telephone: 770-368-4700 www .
Een belangrijk punt na aankoop van elk apparaat Graham Field US0208PL (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graham Field US0208PL heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graham Field US0208PL vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graham Field US0208PL leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graham Field US0208PL krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graham Field US0208PL bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graham Field US0208PL kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graham Field US0208PL . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.