Gebruiksaanwijzing /service van het product LCD-2A van de fabrikant Grindmaster
Ga naar pagina of 20
0910 Form # AM-328-04 Part # 63543 GRINDMASTER CORPORA TION ™ Liquid Cof fee Dispenser Operation and Instruction Manual for LCD-2A (Ambient Cabinet) & LCD-2R (Refrigerated Cabinet) © Grindmaster Corporation, 2009 Printed in USA T ABLE OF C ONTENTS Prior authorization must be obtained from Grindmaster Corporation for all warranty claims.
Page 2 Model LCD-2R and LCD-2A Introduction The Grindmaster-Cecilware Liquid Coffee Dispensers (LCD-2A) and the Liquid Coffee Chilled Dispenser (LCD-2R) deliver two types of coffee made from liquid concentrate plus hot water .
Page 3 Model LCD-2R and LCD-2A User Replaceable Part s .
Page 4 Model LCD-2R and LCD-2A W arning Labels The following warning labels were on your dispenser when it was shipped from the factory . They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replace- ment label immediately .
Page 5 Model LCD-2R and LCD-2A Inst allation W ater Inlet Connection: The National Sanitation Foundation requires the following for an NSF approved water hook-up: 1. A quick disconnect water connection or enough coiled tubing so that the machine can be moved for cleaning underneath.
Page 6 Model LCD-2R and LCD-2A Inst allation (cont.) Electrical Hook-up: Ensure water connection is made to machine before proceeding and water source is turned ON. The electrical ratings for your dispenser are located on the serial plate on the outside cabinet.
Page 7 Model LCD-2R and LCD-2A 9. Af ter the water tank has completed the fill cycle, the display located on the front door of the dispenser should indicate that the heating element has been activated. Allow 10-60 minutes for the water tank to reach operating temperature.
Page 8 Model LCD-2R and LCD-2A Open the door and insert Setup key into keyswitch above cooler compartment. T urn key ¼ turn clock- wise, the display on front of door will say ‘Setup Mode, Press Enter ’.
Page 9 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Engineer Mode T o access engineer mode go into Setup mode, when the screen says ‘Setup Mode, Press Enter ’ press the Hot W ater tap – the display will now say ‘Engineer Mode, Press Enter’.
Page 10 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Engineer Mode (cont.) No prod, Stop Sel [Disabled]: No product, stop Selection. If enabled, when the cof fee goes low during a dispense it will stop, giving a low measure.
Page 11 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Machine Fault Codes (cont.) 6: W ater overheat The thermistor has detected the water is too hot. The boiler element cont actor may have failed short circuit.
Page 12 Model LCD-2R and LCD-2A T o check water flow rate and calibrate the actual mix ratio adjustment to match the programming mix ratio: “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Programming Guide for Calibration of Mix Ratio (cont.
Page 13 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Programming Guide for Calibration of Mix Ratio (cont.
Page 14 Model LCD-2R and LCD-2A W eekly Cleaning Instructions refer to Figure E NOTE: Some bag-in-box connectors require some disassembly for cleaning and sanitizing NOTE: Some bag-in-box connectors requires some extra steps for cleaning and sanitizing.
Page 15 Model LCD-2R and LCD-2A Service and Cleaning Draining the T ank Always empty the tank before shipping. 1. Prep are a minimum 5 gallon (17.5 litre) heat resistant cont ainer to drain the tank water into. 2. Unplug the machine. 3. Remove the drain tray and front access p anel.
Page 16 Model LCD-2R and LCD-2A T roubleshooting Guide A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problem encountered. If the problem remains af ter exhausting the troubleshooting steps, cont act Grindmaster- Cecilware T echnical Service Department (800-695-4500, 8am-6pm, M-F).
Page 17 Model LCD-2R and LCD-2A T roubleshooting Guide (cont.) W ARNING: Risk of electrical shock. Disconnect power before removal of any machine access p anels.
Page 18 Model LCD-2R and LCD-2A Problem/Cause Remedy LCD DISPLA Y INDICA TES “OVERFLOW” NOTE: Water must be drained from the tank below the float switch af ter the fault condition is diagnosed.
*5((1< *5< 5(' *5< 5(' %/. &RQQHFWWR/DVVKRZQIRUYROWZDWW PLQLPXP$:*FRUGDJHRU &RQQHFW.
Grindmaster® Coffee Grinders and Br ewers • PrecisionBr ew™ Brewing Systems • Espressimo® Espr esso Machines Crathco® Hot Beverage Dispensers • Crathco® Cold and Frozen Beverage Dispensers • AMW Cof fee and T ea Systems T el (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 (USA & Canada only) P .
Een belangrijk punt na aankoop van elk apparaat Grindmaster LCD-2A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Grindmaster LCD-2A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Grindmaster LCD-2A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Grindmaster LCD-2A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Grindmaster LCD-2A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Grindmaster LCD-2A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Grindmaster LCD-2A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Grindmaster LCD-2A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.