Gebruiksaanwijzing /service van het product AD-24 Phase 7 van de fabrikant American Dryer Corp.
Ga naar pagina of 50
AD-24 Installa tion Manual Phase 7 ADC Part No. 1 13222 - 5 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA T elephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry .
“IMPORT ANT NO TE T O PURCHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas.
W ARNING UNDER NO CIRCUMST ANCES should the dryer door switch, lint door switch, or heat safety circuit ever be disabled. IMPOR T ANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS S.
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer .
Table of Contents SECTION I SAFETY PRECAUTIONS .......................................................................................... 3 SECTION II SPECIFICA TIONS ....................................................................................
SECTION VI ROUTINE MAINTENANCE ................................................................................... 3 2 A. Cleaning ........................................................................................................................
1 13222 - 5 w ww .amdry .com 3 SECTION I SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life.
4 American Dryer Corp. 1 13222 - 5 W ARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard. G .
1 13222 - 5 w ww .amdry .com 5 SECTION II SPECIFICA TIONS Electric Gas M AXI MU M CAP ACI T Y (DR Y W EI G H T ) 2 0 lb 9.07 kg T U M BL E R D I A M E T E R 27- 1/ 4” 69. 22 cm T U MBLER DEPT H 2 4 ” 60. 96 cm T UM B LER VOLU ME 8 . 1 0 c u f t 229.
6 American Dryer Corp. 1 13222 - 5 S pecifications NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
1 13222 - 5 w ww .amdry .com 7 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI.
8 American Dryer Corp. 1 13222 - 5 6. Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Section C ).
1 13222 - 5 w ww .amdry .com 9 NOTE: Air considerations are important for proper and efficient operation. D. FRESH AIR SUPPL Y REQUIREMENTS Air supply (make-up air) must be given careful consideration to ensure proper performance of each dryer . An unrestricted source of air is necessary for each dryer .
10 American Dryer Corp. 1 13222 - 5 E. EXHAUST REQUIREMENTS Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure.
1 13222 - 5 w ww .amdry .com 11 SINGLE DR YER VENTING IMPOR T ANT : A minimum exhaust duct size of 6-inches (15.24 cm) must be used. For a 6-inch (15.24 cm) horizontal run where a maximum of one (1) elbow is used (refer to the illustration below ), the ductwork from the dryer outlet must not exceed 8 feet (2.
12 American Dryer Corp. 1 13222 - 5 SINGLE DR YER VENTING IMPOR T ANT : A minimum exhaust duct size of 8-inches (20.32 cm) must be used. For an 8-inch (20.32 cm) horizontal run where a maximum of one (1) elbow is used (refer to the illustration below ), the ductwork from the dryer outlet must not exceed 40 feet (12.
1 13222 - 5 w ww .amdry .com 13 When single 8-inch (20.32 cm) vertical venting is used (refer to the illustration below ), the ductwork from the dryer to the outside outlet cannot exceed 35 feet (10.67 meters) in total length. This calculation of 35 feet (10.
14 American Dryer Corp. 1 13222 - 5.
1 13222 - 5 w ww .amdry .com 15 IMPOR T ANT : For extended ductwork runs, the cross section area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits as noted in this manual, a professional heating, ventilating, and air-conditioning (HV AC) firm should be consulted for proper venting information.
16 American Dryer Corp. 1 13222 - 5 F . ELECTRICAL INFORMA TION 1. Electrical Requirements ALL electrical connections must be made by a properly licensed and competent electrician . This is to ensure that the electrical installation is adequate and conforms to local and state regulations or codes.
1 13222 - 5 w ww .amdry .com 17 2. Electrical Service Specifications IMPOR T ANT : Figures shown are for non-reversing models only . For reversing models contact the factory . a . Gas Models Only * 3-Wire is available. 6/3/08 * 3-Wire is available. 6/3/08 b .
18 American Dryer Corp. 1 13222 - 5 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO.
1 13222 - 5 w ww .amdry .com 19 A ground lug is provided in the rear electrical box to connect your service ground. FOR 1 10V APPLICA TIONS FOR 208-240V APPLICA TIONS S i ng l e - P ha s e E l e c t r.
20 American Dryer Corp. 1 13222 - 5 The neutral will only be used on 4-wire service. This is typical for 380-416V , 50 Hz. b . Electrically Heated Models Only The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes neutral) and ground.
1 13222 - 5 w ww .amdry .com 21 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
22 American Dryer Corp. 1 13222 - 5 2. T echnical Gas Data a . Gas Specifications Shaded areas are stated in metric equivalents * Measured at outlet side of gas valve pressure tap when gas valve is on. b. Gas Connections: Inlet connection ---- 1/2” N.
1 13222 - 5 w ww .amdry .com 23 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P .
24 American Dryer Corp. 1 13222 - 5 H. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ W ARNING ,” and “ DIRECTION ” labels attached to the dryer .
1 13222 - 5 w ww .amdry .com 25 NOTE: Gas model dryers are equipped with an ignition system, which has internal diagnostics. If ignition is not established after one (1) time, the heat circuit in the ignition module will attempt two (2) more ignitions (total of three [3] ignition attempts).
26 American Dryer Corp. 1 13222 - 5 J. PREOPERA TIONAL INSTRUCTIONS COIN MODELS 1. Microprocessor Controller (Computer) a. When the microprocessor controller (computer) is in the ready state, the liquid crystal display (L.C.D.) screen will display “Ready , Insert $XX.
1 13222 - 5 w ww .amdry .com 27 NON-COIN MODELS 1. The light emitting diode (L.E.D.) display reads “READY” (no cycle in progress). 2. Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.
28 American Dryer Corp. 1 13222 - 5 K. SHUTDOWN INSTRUCTIONS If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed: 1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker .
1 13222 - 5 w ww .amdry .com 29 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE Service must be performed by a qualified trained technician, service agency , or gas supplier . If service is required, contact the reseller from whom the ADC equipment was purchased.
30 American Dryer Corp. 1 13222 - 5 SECTION V W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass.
1 13222 - 5 w ww .amdry .com 31 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c . Date of dryer installation. d. Date of part failure.
32 American Dryer Corp. 1 13222 - 5 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system.
1 13222 - 5 w ww .amdry .com 33 90 DA YS 1. Remove lint from around basket (tumbler), drive motors, and surrounding areas. 2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. 3. Clean any lint accumulation in and around both the blower and drive motor casing openings.
34 American Dryer Corp. 1 13222 - 5 When contacting American Dryer Corporation , certain information is required to ensure proper service/parts information from ADC . This information is on the data label affixed to the left side panel area behind the top control (access) door .
1 13222 - 5 w ww .amdry .com 35 THE DA T A LABEL 1. MODEL NUMBER The model number is an ADC number , which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer .
36 American Dryer Corp. 1 13222 - 5 SECTION VIII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Phase 7 Coin Models 1) Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer .
1 13222 - 5 w ww .amdry .com 37 b. Phase 7 Non-Coin Models 1) Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer . 2) Start the drying cycle by pressing any of the preset cycles in letters A-F .
38 American Dryer Corp. 1 13222 - 5 2. For Models with Direct Spark Ignition (DSI) Module (T ype I) Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for.
1 13222 - 5 w ww .amdry .com 39 The exclusive Sensor Activated Fire Extinguishing (S.A.F .E.) System will extinguish fires that may start in the drying basket (tumbler). A series of sensors positioned throughout the basket (tumbler) and interfaced with the microprocessor will trigger the S.
40 American Dryer Corp. 1 13222 - 5 BEFORE YOU ST ART! CHECK LOCAL CODES AND PERMITS Call your local water company or the proper municipal authority for information regarding local codes.
1 13222 - 5 w ww .amdry .com 41 2. W ater Connections: The water connection is made to the 3/4”-1 1.5 NH hose adapter of the electric water solenoid valve, located at the rear upper midsection of the dryer (refer to the photo). The water solenoid valve has a 3/8” M.
42 American Dryer Corp. 1 13222 - 5 OPTIONAL MANUAL BYP ASS Provisions are made in the dryer S.A.F .E. system for the installation of an optional manual bypass. Depending on the model dryer , the connections for the manual bypass are made at the “T” or “three way” fitting located in the outlet supply side of the water solenoid valve.
1 13222 - 5 w ww .amdry .com 43 S.A.F .E. System Theory of Operation While the dryer is in an idle state, or 20-seconds after the heat turns off, the Phase 7 control monitors the thermistor probe, located in the top of the basket (tumbler) chamber , and records the minimum temperature.
44 American Dryer Corp. 1 13222 - 5 S.A.F .E. SYSTEM W A TER V AL VE CHECK The operation of the water solenoid valve can be tested to ensure that the water supply system and valve are functional.
1 13222 - 5 w ww .amdry .com 45 S.A.F .E. SYSTEM DIAGNOSTICS MESSAGES OPEN THERMISTOR PROBE – This message indicates that the S.A.F .E. system thermistor probe either is not connected or is damaged. If this condition is detected, the Phase 7 non-coin control will immediately enter S.
ADC Part No. 1 13222 5 - 06/03/08 - 100.
Een belangrijk punt na aankoop van elk apparaat American Dryer Corp. AD-24 Phase 7 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen American Dryer Corp. AD-24 Phase 7 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens American Dryer Corp. AD-24 Phase 7 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding American Dryer Corp. AD-24 Phase 7 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over American Dryer Corp. AD-24 Phase 7 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van American Dryer Corp. AD-24 Phase 7 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de American Dryer Corp. AD-24 Phase 7 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met American Dryer Corp. AD-24 Phase 7 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.