PNEG -338 Port able Dryer Inst allation and To w i n g Inst allation and T owing Manual PNEG-338 Date: 09-18-07.
2 PNEG-338 Portab le Dryer Installation Manua l.
PNEG-338 Portab le Dryer Installation Ma nual 3 T able of Content s Contents Chapter 1 Introduction .............. ............................. ............................. ............................. .. . .......................... ...... 4 Chapter 2 Safety .
4 PNEG-338 Portable Dryer Installation Manual 1. Introduction READ THIS MANUAL carefully to learn ho w to properl y use and install equipment. Failure to do so could result in personal injury or equ ipment damage. INSPECT the shipment immediately upon arrival.
PNEG-338 Portable Dryer In st allation Manual 5 2. Safety Safety Guidelines This manual contains information that is important for you, the owner/opera tor, to know and understand. This information relates to protectin g personal safety and preventing equipment problems.
6 PNEG-338 Portable Dryer Installation Manual 2. Safety Emergency S top Switch The emergency stop switch is located on the upper control box d oor. Pushing the emergency stop switch will interrupt the control power and stop all drye r functions.
2. Safety PNEG-338 Portable Dryer In st allation Manual 7 Safety Precautions READ THESE INSTRUCTIONS BEFORE INSTALLATION AND OPERATION SAVE FOR FUTURE REFERENCE 1. Read and understand the op erating manual before trying to o perate the dryer. 2. NEVER operate the dryer while the guards are removed.
8 PNEG-338 Portable Dryer Installation Manual 2. Safety Safety Sign-Off Sheet As a requirement of O.S.H.A., it is necessary for the emplo yer to train the employee in the safe operating and safety procedures for this auge r. Th is sign -o ff shee t is provided for your convenience and persona l record keeping.
PNEG-338 Portable Dryer In st allation Manual 9 3. Safety Alert Decals The GSI Group recommends contacting your local pow er company and ha ving a represent ative survey your installation so the wiring is compatible with their system and adeq uate power is supplied to your unit.
10 PNEG-338 Portable Dryer Installation Manual 3. Safety Alert Decals DC-974 Rotating auger will crush and cut. Auto equipment can start at anytime. Do not enter until electric power is locked in off position. Failure to do so will result in serious injury or death.
3. Safety Alert Decals PNEG-338 Portable Dryer In st allation Manual 1 1 DC-1229 W ARNING Rotating metering roll. Equipment can start automatically . Keep hands clear . Can cause serious injury . Disconnect power before servicing. DC-1227 Flame and pressure beyond door can cause serious injury .
12 PNEG-338 Portable Dryer Installation Manual 3. Safety Alert Decals 16-17" 3/4" MINIMUM BOL T DIAMETER DC-388 Hitch pin must be securely fastened and no less than 3/4" in diameter . Failure to follow installation instructions may result in property damage.
PNEG-338 Portable Dryer In st allation Manual 13 4. T ransporting the Dryer The dryer is available with an op tional transport kit for transporting the unit by truck or tractor. Make certain to observe the following safety precautions. 1. Recommended towing hitch height is 14"-17''.
14 PNEG-338 Portable Dryer Installation Manual 5. Inst allation Location of the Dryer When considering the exact location of the drye r, also consider th e we t grain supply and dry grain discharge, as well as the location of storage bin s a nd other grain handling equip ment.
5. Inst allation PNEG-338 Portable Dryer In st allation Manual 15 Figure 5A Diagram of Dryer Dimensions T ransport and Inst allation Dimensions Driver Model # AB C D E F G H T ransport Height Instal l.
16 PNEG-338 Portable Dryer Installation Manual 6. Foundation Layout T y pical of Dryer Line Figure 6A.
PNEG-338 Portable Dryer In st allation Manual 17 7. Foundation Specific ations for Dryer Minimum Bag Mix for Concrete S trength per Model W eight Dryer Basket Length 6 8 10 12 14 16 18 20 22 26 Concrete Pad Size 12 x 16 12 x 18 12 x 20 12 x 22 12 x 24 12 x 26 12 x 28 12 x 30 12 x 32 12 x 36 Y ards Concre te 5.
18 PNEG-338 Portable Dryer Installation Manual 8. Fuel Connection Liquid Prop ane (LP) Liquid Draw The dryers have internal vaporizers and are designed to operate on liq uid draw from the supply tank. The tank should be 1000 gallons or larger and should not have a regulator mounted to it.
8. Fuel Connecti on PNEG-338 Portable Dryer In st allation Manual 19 Fuel System S pecifications and Recommen dations (LP) Liquid Prop ane Natural Gas (N) Gas V olume and Pressure The dryer is designed to operat e on natural gas having a heat value of approximately 1000 BTU per cubic foot.
20 PNEG-338 Portable Dryer Installation Manual 8. Fuel Connection Fuel System S pecifications and Re commendations (N) Natural Gas Figure 8C The fuel con nection point is equi pped with a Y -strainer and Maxon safety valve. Dryer Model # Maximum Heat Capacity BTU Per Hour Maximum Fuel Flow Cubic Feet Per Ho ur Fuel Line S i ze* (Dia.
PNEG-338 Portable Dryer In st allation Manual 21 9. Electrical Power Supply Power Supply An adequate power supply and proper wiring are important factors for maximum perfo rmance and long life of the dryer. Electrical service must be adequate to prevent low voltage damage to motors and control circuits.
22 PNEG-338 Portable Dryer Installation Manual 9. Electrical Power Supply Proper Inst allation of Ground Rod The rod should not be driven into dry ground. Fo llow these instructions for proper installation. 1. Dig a hole large enough to ho ld one (1) to two (2) gallons of wa ter.
PNEG-338 Portable Dryer In st allation Manual 23 10. Electrical Load Information The following charts provide info rmation for the electrician wiring the grain dryer and are a refe rence guide for parts.
24 PNEG-338 Portable Dryer Installation Manual 10. Electrical Load Information 111 4 1 PH 230V T op A uger 5 26 231 130 350 100 Bottom Auge r 5 26 100 Fan 10 to 17 78 100 (2) Auxilia ry (2) 7.5 62 * 3 PH 220V T op A uger 5 13.2 145 65.4 200 60 Bottom Auge r 5 13.
10. Electrical Load Information PNEG-338 Portable Dryer In st allation Manual 25 11 2 6 3 PH 220V T op A uger 10 26 277 154 400 90 Bottom Auge r 10 26 90 Fan 40 102 125 (2) Auxilia ry (2) 15 78 * 3 PH.
26 PNEG-338 Portable Dryer Installation Manual 10. Electrical Load Information 1218 1 PH 230V T op A uger 5 26 286 178 400 100 Bottom Auge r 5 26 100 To p F a n 10 to 17 78 100 Bottom Fan 10 t o 12 48 100 (2) Auxilia ry (2) 7.5 62 * 3 PH 220V T op A uger 5 13.
10. Electrical Load Information PNEG-338 Portable Dryer In st allation Manual 27 1214S 1 PH 230V T op A uger 5 26 252 148 350 C303B 100 Bottom Auger 5 26 C303B 100 (2) Fans (2) 10 to 12 96 F614B 100 (2) Auxilia ry (2) 7.5 62 C330B * 3 PH 220V T op A uger 5 13.
28 PNEG-338 Portable Dryer Installation Manual 10. Electrical Load Information 1226S 3 PH 220V T op A uger 10 26 307 180 400 90 Bottom Auge r 10 26 90 (2) Fans (2) 25 128 90 (2) Auxilia ry (2) 15 78 *.
10. Electrical Load Information PNEG-338 Portable Dryer In st allation Manual 29 160AB 1 PH 230V T op A uger 1 6.5 151 61 200 50 Bottom Auge r 1 6.5 50 Fan 10 to 12 48 60 (2) Auxilia ry (2) 7.5 62 * T op A uger 1 3.4 102 39.8 150 60 3 PH 220V Bottom Auge r 1 3.
30 PNEG-338 Portable Dryer Installation Manual 10. Electrical Load Information 400AB 1 PH 230V T op A uger 5 26 231 130 350 100 Bottom Auge r 5 26 100 Fan 10 to 17 78 100 (2) Auxilia ry (2) 7.5 62 * 3 PH 220V T op A uger 5 13.2 145 65.4 200 60 Bottom Auge r 5 13.
PNEG-338 Portable Dryer Inst allation Manual 31 1 1. W arranty The GSI Group Warranty THE GSI GROUP (GSI) WARRANTS ALL PRODUCT S WHICH IT MANUFACTURES TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USAGE AND CONDITIONS FOR A PERIOD OF 12 MONTHS AFTER RETAIL SALE TO THE ORIGIN AL END USER.
T his equipment shall be in stalled in a ccordance with the cur rent installation codes and applica ble re gulations which should be ca refull y f ollo wed in all cases. Authorities ha ving jurisdiction should be consulted before inst allations are made.
Een belangrijk punt na aankoop van elk apparaat GSI Outdoors PNEG-338 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GSI Outdoors PNEG-338 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GSI Outdoors PNEG-338 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GSI Outdoors PNEG-338 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GSI Outdoors PNEG-338 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GSI Outdoors PNEG-338 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GSI Outdoors PNEG-338 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GSI Outdoors PNEG-338 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.