Gebruiksaanwijzing /service van het product G65 van de fabrikant GSW
Ga naar pagina of 24
COMMERCIAL GAS W A TER HEA TER INST ALLA TION, OPERA TING AND MAINTENANCE INSTR UCTION MANU AL - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHA T TO DO IF YOU SMELL GAS - Do not try to light any appliance.
IMPORT ANT FOR THE INST ALLER AND USER OF THIS GAS FIRED W A TER HEA TER These instructions have been written for the proper installation and safe operation of this water heater . The installation must conform with one or more of the follow- ing as applicable: Canadian Installation: 1.
Page 2 Figure 1 1. Cold water inlet 2. Hot water outlet 3. Gas supply manual shut-off valve 4. Sediment trap 5. Union - ground joint type 6. Gas control 7.
W A TER PIPING Pipes and fittings should be installed in compliance with the installation drawing. Makes sure the dip tube is in the cold water fitting and water connections are made correctly . Have the installer show you where the water shut-of f valve for the water heater has been installed so that you know where and how to shut the water off.
The installation of this appliance must conform to applicable local codes and local authorities having jurisdictions. Install the gas piping as indicated in Figure 2.
INPUT BTU/HR. 58,000 90,000 135,000 160,000 180,000 200,000 225,000 270,000 315,000 360,000 NA TURAL GAS 1000 BTU/CU. FT . 62 SEC. 40 SEC. 27 SEC. 22 SEC. 20 SEC. 18 SEC. 16 SEC. 13 SEC. 12 SEC. 10 SEC. PROP ANE 2500 BTU/CU. FT . 155 SEC. 100 SEC. 67 SEC.
FLUE DAMPER Flue Damper Inst allation For Models equipped with a flue damper , the following instructions must be followed. It is recommended to leave a minimum 24” clearance from the actuator side of the flue damper for service access. S tep 1: Place flue damper on top pan into flue collector .
Connection Diagram Appliance in St andby Condition The motor is energized during appliance thermostat “of f” cycle. The flue damper is the “closed” position. Circuit diagram is as shown. SL VENT DAMPER 128 V AC 24 V R1 (N.C.) R2 (N.O.) SS2 (N.
20 V AC 24 V AC E.C.O. TH. R1 (N.C.) FUSE R2 (N.O.) SS2 (N.O.) E.S.(N.O.) VENT DAMPER VA LV E GND. 2 M 3 4 1 20 V AC 24 V AC E.C.O. TH. R1 (N.C.) FUSE R2 (N.O.) SS2 (N.O.) E.S.(N.O.) VENT DAMPER VA LV E GND. 2 M 3 4 1 On Appliance Call for Heat - S t age 1 The thermostat cont acts close and they relay coil is energized.
ELECTRONIC IGNITION MODELS: ROBERTSHA W IGNITION MODULE AND V AL VE SCHEMA TIC DIAGRAM L1 (HOT) 120 V AC L2 (NEU.) L3 (GND) 24 VOL T TRANSFORMER MOTOR SERV .
Page 10 ROBERTSHA W CONTROL MODULE SP745 MV TH PV/MV TR GND PV ING ROBERTSHA W V AL VE TEMPERA TURE CONTROL TH TR D D O ECO TH O ST YELLOW MV TH TR TH TR PV PV/MV WHITE RODGERS V AL VE PV PV TH TR MV PV/MV MV SP ARK ELECTRODE L3 (GND.
Page1 1 AIR SUPPL Y Ensure that adequate ventilation is available to supply make-up air for proper combustion. Openings sufficient to provide one square inch of free area for each 1,000 BTU/hr . input rating of all appliances must be provided for this purpose.
Page 12 LIGHTING INSTRUCTIONS WHITE - RODGERS GAS CONTROLS 1. STOP! Read the safety information at the head of this section. 2. Set the thermostat to lowest setting. (Rotate dial clock -wise). 3. Depress gas control slightly and turn clock-wise to “OFF”.
Page 13 LIGHTING INSTRUCTIONS FOR ELECTRONIC IGNITION GAS MODELS FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance is equipped with an ignition device which automatically lights the pilot, DO NOT TR Y TO LIGHT MANUALL Y . B. BEFORE LIGHTING , smell around the appliance area for gas.
Page 14 COMMERCIAL GAS E.I. TROUBLESHOOTING SEQUENCE For Honeywell V alve NOTE: T roubleshooting should be done by qualified service personnel familiar with the start-up and checkout procedure.
Page 15 LP (PROP ANE) GAS MODELS LP . GAS IS HEA VIER THAN AIR. Should there be a leak in the system, the gas will settle at FLOOR LEVEL. Basements, crawl sp aces, closets and areas below ground level will serve as pockets for the accumulation of the gas.
Page 16 GENERAL HOUSEKEEPING As a precaution against fire, and to maintain an adequate flow of combustion air to the heater: - Keep the appliance area clear and free from com- bustible material, gasoline and other flammable vapours and liquids. - Keep any ventilation and combustion air openings unobstructed.
Page 17 CA THODIC PROTECTION Depending on the model, two or three magnesium anodes are factory installed inside the t ank to provide corrosion protection and to extend tank life. Permanent removal of the anode(s) for any purpose will void the warranty .
Page 18 INST ALLA TION DIAGRAMS TWO TEMPERA TURE COLD W A TER INLET MIXING V AL VE TEMPERED OUTLET 6” MIN. SINGLE TEMPERA TURE OR BOOSTER HOT W A TER OUTLET COLD W A TER INLET OR TEMPERED W A TER IN.
Page 19 SINGLE TEMPERA TURE GRA VITY CIRCULA TION WITH HORIZONT AL ST ORAGE T ANK STORAGE T ANK (INSULA TED) 2” RISER 5” MIN. 1 1/2 MIN. COLD W A TER INLET HOT W A TER OUTLET T&P RELIEF VA LV .
Page 20 (1) WITH HORIZONT AL STORAGE T ANK STORAGE T ANK (INSULA TED) 2” RISER TEMPERA TURE & PRESSURE RELIEF VA LV E T ANK TEMPERA TURE CONTROL PLUG COCK (1) CHECK VA LV E (2) COLD W A TER INLET 3/4” .
Page 21 TWO TEMPERA TURE GRA VITY CIRCULA TION WITH HORIZONT AL ST ORAGE T ANK AND MIXING V AL VE TEMPERA TURE & PRESSURE RELIEF V AL VE THERMOMETER 1-1/2” MIN. INSULA TED GA TE VA LV E COLD W A TER SUPPL Y 1-1/2” MIN. 5” MIN. TEMPERED W A TER OUTLET MIXING V AL VE COLD W A TER SUPPL Y 6” MIN.
Page 22 INST ALLA TION RECORD This water heater is protected by a multi-year warranty against leaks, plus a one year warranty on parts. Record key dat a here for future reference and prompt service.
Page 23 *THREE YEAR W ARRANTY IMPORT ANT : Fill out this W arranty and keep for future reference. MODEL NO. SERIAL NO. DA TE INST ALLED Owner: INST ALLA TION ADDRESS: GSW W A TER PRODUCTS COMP ANY war.
Een belangrijk punt na aankoop van elk apparaat GSW G65 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GSW G65 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GSW G65 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GSW G65 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GSW G65 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GSW G65 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GSW G65 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GSW G65 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.